Optical diagnostics of laser-produced plasmas

被引:79
|
作者
Harilal, S. S. [1 ]
Phillips, M. C. [2 ]
Froula, D. H. [3 ]
Anoop, K. K. [4 ]
Issac, R. C. [4 ]
Beg, F. N. [5 ]
机构
[1] Pacific Northwest Natl Lab, Richland, WA 99352 USA
[2] Univ Arizona, James C Wyant Coll Opt Sci, Tucson, AZ 85721 USA
[3] Univ Rochester, Lab Laser Energet, Rochester, NY 14623 USA
[4] Cochin Univ Sci & Technol, Dept Phys, Cochin 682022, Kerala, India
[5] Univ Calif San Diego, Ctr Energy Res, La Jolla, CA 92093 USA
关键词
INDUCED BREAKDOWN SPECTROSCOPY; URANIUM ISOTOPE RATIOS; ION-ACOUSTIC-WAVES; ELECTRON-DENSITY MEASUREMENTS; INDUCED-FLUORESCENCE; SOLID SAMPLES; TEMPERATURE-MEASUREMENTS; ABSORPTION-SPECTROSCOPY; EMISSION-SPECTROSCOPY; RESOLVED ABSORPTION;
D O I
10.1103/RevModPhys.94.035002
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Laser-produced plasmas (LPPs) engulf exotic and complex conditions ranging in temperature, density, pressure, magnetic and electric fields, charge states, charged particle kinetics, and gas-phase reactions based on the irradiation conditions, target geometries, and background cover gas. The application potential of the LPP is so diverse that it generates considerable interest for both basic and applied research areas. The fundamental research on LPPs can be traced back to the early 1960s, immediately after the invention of the laser. In the 1970s, the laser was identified as a tool to pursue inertial confinement fusion, and since then several other technologies have emerged out of LPPs. These applications prompted the development and adaptation of innovative diagnostic tools for understanding the fundamental nature and spatiotemporal properties of these complex systems. Although most of the traditional characterization techniques developed for other plasma sources can be used to characterize the LPPs, care must be taken to interpret the results because of their small size, transient nature, and inhomogeneities. The existence of the large spatiotemporal density and temperature gradients often necessitates nonuniform weighted averaging over distance and time. Among the various plasma characterization tools, optical-based diagnostic tools play a key role in the accurate measurements of LPP parameters. The optical toolbox contains optical spectroscopy (emission, absorption, and fluorescence), as well as passive and active imaging and optical probing methods (shadowgraphy, Schlieren imaging, interferometry, Thomson scattering, deflectometry, and velocimetry). Each technique is useful for measuring a specific property, and its use is limited to a certain time span during the LPP evolution because of the sensitivity issues related to the selected measuring tool. Therefore, multiple diagnostic tools are essential for a comprehensive insight into the entire plasma behavior. Recent improvements in performance in laser and detector systems have expanded the capability of the aforementioned passive and active diagnostic tools. This review provides an overview of optical diagnostic tools frequently employed for the characterization of the LPPs and emphasizes techniques, associated assumptions, and challenges. Considering that most of the industrial and other applications of the LPP belong to low to moderate laser intensities (10(8)-10(15) W cm(-2)), this review focuses on diagnostic tools pertaining to this regime.
引用
收藏
页数:40
相关论文
共 50 条
  • [1] Optical spectroscopy of laser-produced plasmas for standoff isotopic analysis
    Harilal, S. S.
    Brumfield, B. E.
    LaHaye, N. L.
    Hartig, K. C.
    Phillips, M. C.
    APPLIED PHYSICS REVIEWS, 2018, 5 (02):
  • [2] Optical diagnostics of laser-produced aluminium plasmas under water
    Walsh, N.
    Costello, J. T.
    Kelly, T. J.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2017, 123 (06):
  • [3] Quantitative absorption spectroscopy of laser-produced plasmas
    Weerakkody, Emily N.
    Glumac, Nick G.
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2021, 54 (12)
  • [4] Two-dimensional fluorescence spectroscopy of laser-produced plasmas
    Harilal, S. S.
    LaHaye, N. L.
    Phillips, M. C.
    OPTICS LETTERS, 2016, 41 (15) : 3547 - 3550
  • [5] Optical diagnostics of gold plasmas produced by infrared laser ablation
    Oujja, M.
    Camacho, J. J.
    Sanz, M.
    Castillejo, M.
    de Nalda, R.
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2020, 256
  • [6] Persistence of uranium emission in laser-produced plasmas
    LaHaye, N. L.
    Harilal, S. S.
    Diwakar, P. K.
    Hassanein, A.
    JOURNAL OF APPLIED PHYSICS, 2014, 115 (16)
  • [7] Spatio-temporal evolution of uranium emission in laser-produced plasmas
    Harilal, S. S.
    Diwakar, P. M.
    LaHaye, N. L.
    Phillips, M. C.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2015, 111 : 1 - 7
  • [8] Optical emission features of laterally colliding laser-produced plasmas at different ambient pressures
    Shilpa, S.
    Gopinath, Pramod
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2023, 207
  • [9] Emission enhancement in laser-produced plasmas on preheated targets
    Sangines, R.
    Sobral, H.
    Alvarez-Zauco, E.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2012, 108 (04): : 867 - 873
  • [10] Tracking of oxide formation in laser-produced uranium plasmas
    Skrodzki, P. J.
    Burger, M.
    Jovanovic, I.
    Phillips, M. C.
    Brumfield, B. E.
    Harilal, S. S.
    OPTICS LETTERS, 2018, 43 (20) : 5118 - 5121