An experimental study of structured packing dehumidifier/regenerator operating with liquid desiccant

被引:96
|
作者
Bassuoni, M. M. [1 ]
机构
[1] Tanta Univ, Fac Engn, Dept Power Mech Engn, Tanta, Egypt
关键词
Desiccant dehumidification; Liquid desiccant; Cross flow dehumidifier; Structured packing; MASS-TRANSFER PERFORMANCE; AIR; DEHUMIDIFICATION; MODEL; SYSTEM;
D O I
10.1016/j.energy.2011.02.004
中图分类号
O414.1 [热力学];
学科分类号
摘要
The present work presents an experimental investigation on the performance of the structured packing cross flow desiccant dehumidification system (DDS). This system is referred as DDS; its heart is the dehumidifier/regenerator. It is used to meet a latent heat load by air dehumidification. Calcium chloride (CaCl2) solution is used as the working desiccant material in this system. The structured packing has a density (specific surface area) of 390 m(2)/m(3), corrugation angle of 60 degrees and void fraction of 0.88. The effect of relevant parameters such as air flow rate, desiccant solution flow rate, desiccant solution temperature and concentration and packing thickness on the performance of the system is studied. The performance of the system is evaluated using the mass transfer coefficient, moisture removal rate (MMR), effectiveness and the coefficient of performance (COP). The remarkable increase of mass transfer coefficient and MRR for both deh/reg is observed by increasing both air and solution flow rates. Eventually, the payback period (PP) of the DDS is 11 months with annual running cost savings (Delta C-RC) of about 31.24% compared with vapor compression system (VCS) dehumidification. The overall environmental impacts of DDS are nearly 0.63 of VCS. This may emphasize the need of incorporating a desiccant system along with air conditioning applications. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2628 / 2638
页数:11
相关论文
共 50 条
  • [31] Experimental study of the film thickness in the dehumidifier of a liquid desiccant air conditioning system
    Luo, Yimo
    Wang, Meng
    Yang, Hongxing
    Lu, Lin
    Peng, Jinqing
    ENERGY, 2015, 84 : 239 - 246
  • [32] Experimental investigation on structured packed bed liquid desiccant dehumidifier: An optimal mixture design of experiments strategy
    Bhowmik, Mrinal
    Muthukumar, P.
    Anandalakshmi, R.
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 122 : 232 - 244
  • [33] Experimental Investigation on a Novel Air Dehumidifier Using Liquid Desiccant
    Qiu, G. Q.
    Riffat, S. B.
    INTERNATIONAL JOURNAL OF GREEN ENERGY, 2010, 7 (02) : 174 - 180
  • [34] Experimental analysis of an internally-cooled liquid desiccant dehumidifier
    Zhang, Tao
    Liu, Xiaohua
    Jiang, Jingjing
    Chang, Xiaoming
    Jiang, Yi
    BUILDING AND ENVIRONMENT, 2013, 63 : 1 - 10
  • [35] Analytical solutions of coupled heat and mass transfer processes in liquid desiccant air dehumidifier/regenerator
    Liu, Xiaohua
    Jiang, Yi
    Xia, Jianjun
    Chang, Xiaomin
    ENERGY CONVERSION AND MANAGEMENT, 2007, 48 (07) : 2221 - 2232
  • [36] Critical review of coupled heat and mass transfer models for a liquid desiccant adiabatic dehumidifier and regenerator
    Koronaki, I. P.
    Christodoulaki, R. I.
    Papaefthimiou, V. D.
    Rogdakis, E. D.
    ADVANCES IN BUILDING ENERGY RESEARCH, 2014, 8 (02) : 117 - 136
  • [37] Coupled heat and mass transfer characteristic in packed bed dehumidifier/regenerator using liquid desiccant
    Liu, X. H.
    Jiang, Y.
    ENERGY CONVERSION AND MANAGEMENT, 2008, 49 (06) : 1357 - 1366
  • [38] An experimental study of a forced flow solar collector/regenerator using liquid desiccant
    Alizadeh, S
    Saman, WY
    SOLAR ENERGY, 2002, 73 (05) : 345 - 362
  • [39] Experimental study of the heat and mass transfer in a packed bed liquid desiccant air dehumidifier
    Oberg, V
    Goswami, DY
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 1998, 120 (04): : 289 - 297
  • [40] Experimental study on mass transfer performances of cross flow dehumidifier using liquid desiccant
    Liu, X. H.
    Zhang, Y.
    Qu, K. Y.
    Jiang, Y.
    ENERGY CONVERSION AND MANAGEMENT, 2006, 47 (15-16) : 2682 - 2692