Endograft apposition and infrarenal neck enlargement after endovascular aortic aneurysm repair

被引:9
作者
Van der Riet, Claire [1 ]
De Rooy, Philippe M. [1 ]
Tielliu, Ignace F. [1 ]
Kropman, Rogier H. [2 ]
Wille, Jan [2 ]
Narlawar, Ranjeet [3 ]
Elzefzaf, Nada Y. [4 ]
Antoniou, George A. [4 ,5 ]
De Vries, Jean-Paul [1 ]
Schuurmann, Richte C. [1 ,6 ]
机构
[1] Univ Med Ctr Groningen, Dept Vasc Surg, NL-9700 Groningen, Netherlands
[2] St Antonius Hosp, Dept Vasc Surg, Nieuwegein, Netherlands
[3] Northern Care Alliance NHS Grp, Royal Oldham Hosp, Dept Radiol, Manchester, Lancs, England
[4] Manchester Univ NHS Fdn Trust, Dept Vasc Surg & Endovasc Surg, Manchester, Lancs, England
[5] Univ Manchester, Sch Med Sci, Div Cardiovasc Sci, Manchester, Lancs, England
[6] Univ Twente, Tech Med Ctr, Multimodal Med Imaging Grp, Enschede, Netherlands
关键词
  Aortic aneurysm; abdominal; Imaging; three-dimensional; Stents; PRACTICE GUIDELINES; IA ENDOLEAK; DILATATION; POSITION; EXPANSION; CURVATURE; MIGRATION;
D O I
10.23736/S0021-9509.21.11972-X
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Sufficient apposition and oversizing of the endograft in the aortic neck are both essential for durable endovascular aneurysm repair (EVAR). These measures are however not regularly stated on post-EVAR computed tomography angiography (CTA) scan reports. In this study endograft apposition and neck enlargement (NE) after EVAR with an Endurant II(s) endograft were analyzed and associated with supraand infrarenal aortic neck morphology. METHODS: In 97 consecutive elective patients, the aortic neck morphology was measured on the pre-EVAR CTA scan on a 3mensio vascular workstation. The distance between the lowest renal artery and the proximal edge of the fabric (shortest fabric distance, SFD), and the shortest length of circumferential apposition between endograft and aortic wall (shortest apposition length, SAL) were determined on the early postEVAR CTA scan. NE, defined as the aortic diameter change between pre- and post-EVAR CTA scan, was determined at eight levels: +40, +30, +20, +15, +10, 0, -5 and -10 mm relative to the lowest renal artery baseline. The aortic neck diameter and preoperative oversizing were correlated to NE with the Pearson correlation coefficient. The effective post-EVAR endograft oversizing is calculated from the nominal endograft diameter and the post-EVAR neck diameter where the endograft is circumferentially apposed. RESULTS: The median time (interquartile range, IQR) between the EVAR procedure and the pre- and post-EVAR CTA scan was 40 (25, 71) days and 36 (30, 46) days, respectively. The Endurant II(s) endograft was deployed with a median (IQR) SFD of 1.0 (0.0, 3.0) mm. The SAL was <10 mm in 9% of patients and significantly infiuenced by the pre-EVAR aortic neck length (P=0.001), hostile neck shape (P=0.017), and maximum curvature at the suprarenal aorta (P=0.039). The median (interquartile range) SAL was 21.0 (15.0, 27.0) mm with a median (IQR) preEVAR infrarenal neck length of 23.5 (13.0, 34.8) mm. The median (IQR) difference between the SAL and neck length was -5.0 (-12.0, 2.8) mm. Significant (P<0.001) NE of 1.7 (0.9, 2.5) mm was observed 5 mm below the renal artery baseline, which resulted in an effective post-EVAR endograft oversizing <10% in 43% of the patients. No correlation was found between NE and aortic neck diameter or preoperative oversizing. CONCLUSIONS: Circumferential apposition between an endograft and the infrarenal aortic neck, SAL, and NE can be derived from standard postoperative CT scans. These variables provide essential information about the post-procedural endograft and aortic neck morphology regardless of the preoperative measurements. Patients with SAL<10 mm or effective oversizing <10% due to NE may benefit from intensified followup, but clinical consequences of SAL and NE should be evaluated in future longitudinal studies with longer term follow-up.
引用
收藏
页码:600 / 608
页数:9
相关论文
共 23 条
[1]   Endovascular vs. Open Repair for Abdominal Aortic Aneurysm: systematic Review and Meta-analysis of Updated Peri-operative and Long Term Data of Randomised Controlled Trials [J].
Antoniou, George A. ;
Antoniou, Stavros A. ;
Torella, Francesco .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2020, 59 (03) :385-397
[2]   Follow-up after endovascular aortic aneurysm repair can be stratified based on first postoperative imaging [J].
Baderkhan, H. ;
Haller, O. ;
Wanhainen, A. ;
Bjorck, M. ;
Mani, K. .
BRITISH JOURNAL OF SURGERY, 2018, 105 (06) :709-718
[3]   Identifying and grading factors that modify the outcome of endovascular aortic aneurysm repair [J].
Chaikof, EL ;
Fillinger, MF ;
Matsumura, JS ;
Rutherford, RB ;
White, GH ;
Blankensteijn, JD ;
Bernhard, VM ;
Harris, PL ;
Kent, KC ;
May, J ;
Veith, FJ ;
Zarins, CK .
JOURNAL OF VASCULAR SURGERY, 2002, 35 (05) :1061-1066
[4]   The Society for Vascular Surgery practice guidelines on the care of patients with an abdominal aortic aneurysm [J].
Chaikof, Elliot L. ;
Dalman, Ronald L. ;
Eskandari, Mark K. ;
Jackson, Benjamin M. ;
Lee, W. Anthony ;
Mansour, M. Ashraf ;
Mastracci, Tara M. ;
Mell, Matthew ;
Murad, M. Hassan ;
Nguyen, Louis L. ;
Oderich, Gustavo S. ;
Patel, Madhukar S. ;
Schermerhorn, Marc L. ;
Starnes, Benjamin W. .
JOURNAL OF VASCULAR SURGERY, 2018, 67 (01) :2-+
[5]   Intraobserver and interobserver variability of 64-row computed tomography abdominal aortic aneurysm neck measurements [J].
Diehm, Nicolas ;
Kickuth, Ralph ;
Gahl, Brigitta ;
Do, Dai- Do ;
Schmidli, Juerg ;
Rattunde, Henning ;
Baumgartner, Iris ;
Dick, Florian .
JOURNAL OF VASCULAR SURGERY, 2007, 45 (02) :263-268
[6]   Outcomes of endovascular aneurysm repair performed in abdominal aortic aneurysms with large infrarenal necks [J].
Gargiulo, Mauro ;
Gallitto, Enrico ;
Wattez, Helene ;
Verzini, Fabio ;
Massoni, Claudio Bianchini ;
Loschi, Diletta ;
Freyrie, Antonio ;
Haulon, Stephan .
JOURNAL OF VASCULAR SURGERY, 2017, 66 (04) :1065-1072
[7]   Adequate seal and no endoleak on the first postoperative computed tomography angiography as criteria for no additional imaging up to 5 years after endovascular aneurysm repair [J].
Goncalves, Frederico Bastos ;
van de Luijtgaarden, Koen M. ;
Hoeks, Sanne E. ;
Hendriks, Johanna M. ;
ten Raa, Sander ;
Rouwet, Ellen V. ;
Stolker, Robert J. ;
Verhagen, Hence J. M. .
JOURNAL OF VASCULAR SURGERY, 2013, 57 (06) :1503-1511
[8]   A Systematic Review of Proximal Neck Dilatation After Endovascular Repair for Abdominal Aortic Aneurysm [J].
Kouvelos, George N. ;
Oikonomou, Kyriakos ;
Antoniou, George A. ;
Verhoeven, Eric L. G. ;
Katsargyris, Athanasios .
JOURNAL OF ENDOVASCULAR THERAPY, 2017, 24 (01) :59-67
[9]   Change in Aortic Neck Diameter after Endovascular Aortic Aneurysm Repair [J].
Kret, Marcus R. ;
Tran, Kenneth ;
Lee, Jason T. .
ANNALS OF VASCULAR SURGERY, 2017, 43 :115-120
[10]   Risk Factors, Dynamics, and Clinical Consequences of Aortic Neck Dilatation after Standard Endovascular Aneurysm Repair [J].
Oliveira, Nelson F. G. ;
Oliveira-Pinto, Jose ;
van Rijn, Marie J. ;
Baart, Sara ;
Ten Raa, Sander ;
Hoeks, Sanne E. ;
Goncalves, Frederico Bastos ;
Verhagen, Hence J. M. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2021, 62 (01) :26-35