Periprosthetic Supracondylar Femoral Fractures Above a Total Knee Replacement: An Updated Compatibility and Technique Guide for Fixation With a Retrograde Intramedullary Nail

被引:3
作者
Gerow, Daniel E. [1 ]
Ross, Hunter L. [1 ]
Bodrogi, Andrew [2 ]
Johnson, Kory J. [3 ]
Endres, Terrence J. [3 ]
机构
[1] Univ Michigan Hlth, Metro Hlth, 5900 Byron Ctr Ave SW, Wyoming, MI 49519 USA
[2] OrthoIndy, Indianapolis, IN USA
[3] Orthopaed Associates Michigan, Grand Rapids, MI USA
关键词
total knee; periprosthetic fracture; supracondylar femur fracture; retrograde nail; implant; arthroplasty; FEMUR FRACTURES; LOCKED PLATE; ARTHROPLASTY;
D O I
10.1097/BOT.0000000000002236
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Multiple studies have described retrograde nailing as a treatment of periprosthetic supracondylar femoral fractures (OTA/ AO type 33A-C) above total knee replacements (TKRs). It is often difficult to discern which TKRs will be compatible with intramedullary nailing because the femoral component design and intercondylar distance is highly variable among total knee designs. The goal of our study is 3-fold: (1) Review and update previous work of intercondylar distances of all currently available prostheses in the United States. (2) Review retrograde nails currently on the market and associated driving end to nail shaft diameter mismatch and opening reamer sizing. (3) Review technical tricks for executing a retrograde femoral nail for the treatment of periprosthetic supracondylar femur fractures. Methods: Data for the intercondylar distance of the femoral components, diameter of retrograde nails and reamers, and notch compatibility were gathered. Results: The results were compiled and recorded. A "technical tricks" section was included that highlights reduction and fixation techniques. Conclusions: This update further empowers surgeons to use all the tools available when treating periprosthetic femur fractures and allows efficient identification of the compatibility of different TKR designs with various intramedullary nails.
引用
收藏
页码:E92 / E97
页数:6
相关论文
共 45 条
  • [11] Distal femoral replacement for the treatment of periprosthetic distal femoral fractures around a total knee arthroplasty: a metaanalysis
    Wood, Matthew J.
    Al-Jabri, Talal
    Stelzhammer, Thomas
    Brivio, Angela
    Donaldson, James
    Skinner, John A.
    Barrett, David
    ORTHOPEDIC REVIEWS, 2024, 16
  • [12] Periprosthetic Distal Femoral Fractures Around a Total Knee Arthroplasty: a Meta-analysis Comparing Locking compression Plating and Retrograde Intramedullary Nailing
    Al-Jabri, Talal
    Wood, Matthew J.
    Faddul, Farah
    Musbahi, Omar
    Bajracharya, Abhijit
    Magan, Ahmed A.
    Jayadev, Chethan
    Giannoudis, Peter V.
    ORTHOPEDIC REVIEWS, 2024, 16
  • [13] Fix or Replace? Comparable Outcomes With Internal Fixation and Distal Femoral Replacement for Periprosthetic Fractures Above Total Knee Arthroplasty
    Lizcano, Juan D.
    Giakas, Alec M.
    Goh, Graham S.
    Abbaszadeh, Ahmad
    Reddy, Yashas C.
    Courtney, Paul M.
    JOURNAL OF ARTHROPLASTY, 2025, 40 (04) : 1048 - 1054.e1
  • [14] The LISS plate treatment of supracondylar fractures above a total knee replacement : a case-control study
    Norrish, Alan R.
    Jibri, Zaid A.
    Hopgood, Phil
    ACTA ORTHOPAEDICA BELGICA, 2009, 75 (05): : 642 - 648
  • [15] Similar outcomes of locking compression plating and retrograde intramedullary nailing for periprosthetic supracondylar femoral fractures following total knee arthroplasty: a meta-analysis
    Young-Soo Shin
    Hyun-Jung Kim
    Dae-Hee Lee
    Knee Surgery, Sports Traumatology, Arthroscopy, 2017, 25 : 2921 - 2928
  • [16] Periprosthetic supracondylar femoral fractures following knee arthroplasty: a biomechanical comparison of four methods of fixation
    Maekinen, Tatu J.
    Dhotar, Herman S.
    Fichman, Simcha G.
    Gunton, Matthew J.
    Woodside, Mitchell
    Safir, Oleg
    Backstein, David
    Willett, Thomas L.
    Kuzyk, Paul R. T.
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (09) : 1737 - 1742
  • [17] Similar outcomes of locking compression plating and retrograde intramedullary nailing for periprosthetic supracondylar femoral fractures following total knee arthroplasty: a meta-analysis
    Shin, Young-Soo
    Kim, Hyun-Jung
    Lee, Dae-Hee
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2017, 25 (09) : 2921 - 2928
  • [18] Periprosthetic supracondylar femoral fractures following knee arthroplasty: a biomechanical comparison of four methods of fixation
    Tatu J. Mäkinen
    Herman S. Dhotar
    Simcha G. Fichman
    Matthew J. Gunton
    Mitchell Woodside
    Oleg Safir
    David Backstein
    Thomas L. Willett
    Paul R. T. Kuzyk
    International Orthopaedics, 2015, 39 : 1737 - 1742
  • [19] RUSH ROD FIXATION OF SUPRACONDYLAR FRACTURES ABOVE TOTAL KNEE ARTHROPLASTIES
    RITTER, MA
    KEATING, EM
    FARIS, PM
    MEDING, JB
    JOURNAL OF ARTHROPLASTY, 1995, 10 (02) : 213 - 216
  • [20] Locking plates versus retrograde intramedullary nails in the treatment of periprosthetic supracondylar knee fractures. A retrospective multicenter comparative study
    Kyriakidis, Theofylaktos
    Kenanidis, Eustathios
    Akula, Maheswara R.
    Zorman, David
    Tsiridis, Eleftherios
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2019, 50 (10): : 1745 - 1749