A study of arcing fault in the low-voltage electrical installation

被引:0
|
作者
Martel, J-M. [1 ]
Anheuser, M. [1 ]
Berger, F. [2 ]
机构
[1] Siemens Ind BT Low Voltage, Siemensstr 10, D-93055 Regensburg, Germany
[2] Tech Univ Ilmenau, Dept Elect Apparat & Switchgear, D-98693 Ilmenau, Germany
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Currently there is technology capable of detecting arcing conditions in low voltage installations available in the United States and Canada (120 V, 60 Hz). This technology has been developed to increase the protection of those installations against electrical fires. While there is a great interest to apply this technology to higher voltage applications (230/240 Vac, 50/60 Hz) it is important to understand how safety-related requirements might need to change in order to be applicable to these new conditions. This discussion covers aspects governing standard testing methods utilized in the industry, the operational environment of the technology and the need for means that realistically could duplicate a series arc fault in order to have a better understanding of the driving factors impacting both applications. The author suggests an implementation method that can be used as an alternative means of testing which provides a better observation of the occurrence, the stability and the outcome of series arcing.
引用
收藏
页码:199 / 209
页数:11
相关论文
共 50 条
  • [1] Electromagnetic Radiation Behavior of Low-Voltage Arcing Fault
    Kim, Charles J.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2009, 24 (01) : 416 - 423
  • [2] Intermittent arcing fault on underground low-voltage cables
    Hamel, A
    Gaudreau, A
    Côté, M
    IEEE TRANSACTIONS ON POWER DELIVERY, 2004, 19 (04) : 1862 - 1868
  • [3] Detection of series arcing in low-voltage electrical installations
    Hadziefendic, Nedzad
    Kostic, Miomir
    Radakovic, Zoran
    EUROPEAN TRANSACTIONS ON ELECTRICAL POWER, 2009, 19 (03): : 423 - 432
  • [4] Arcing-fault models for low-voltage power systems
    Gammon, T
    Matthews, J
    2000 IEEE INDUSTRIAL & COMMERCIAL POWER SYSTEMS TECHNICAL CONFERENCE, CONFERENCE RECORD, 2000, : 119 - 126
  • [5] A novel approach for arcing fault detection for medium/low-voltage switchgear
    Lee, W. J.
    Sahni, M.
    Methaprayoon, K.
    Kwan, C.
    Ren, Z.
    Sheeley, J.
    2006 IEEE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS TECHNICAL CONFERENCE, CONFERENCE RECORD, 2006, : 178 - +
  • [6] A Novel Approach for Arcing Fault Detection for Medium-/Low-Voltage Switchgear
    Lee, Wei-Jen
    Sahni, Mandhir
    Methaprayoon, K.
    Kwan, Chiman
    Ren, Zhubing
    Sheeley, Joseph M.
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2009, 45 (04) : 1475 - 1483
  • [7] Low-voltage electrical and lightning protection installation in facilities accredited
    Jezercic, I. Aurer
    KEMIJA U INDUSTRIJI-JOURNAL OF CHEMISTS AND CHEMICAL ENGINEERS, 2018, 67 (5-6): : 286 - 288
  • [8] The behavior of arcing faults in low-voltage switchboards
    Land, H. Bruce, III
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2008, 44 (02) : 437 - 444
  • [9] Classification of severity of low-voltage motor coil arcing fault using statistical techniques
    Sahni, M.
    Lee, W. J.
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2009, 3 (01) : 75 - 85
  • [10] Value of Insulated Bus Bars in Reducing Arcing Fault Duration in Low-Voltage Systems
    Rajvanshi, Rahul
    Hawkins, Tom
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2016, 52 (02) : 1280 - 1284