Evaluation of band broadening in chemiluminescence detection coupled to pressurized capillary electrochromatography with an off-column coaxial flow interface

被引:9
作者
Lin, Zian [1 ]
Lin, Jian [1 ]
Wu, Xiaoping [1 ]
Lin, Xucong [1 ]
Xie, Zenghong [1 ]
机构
[1] Fuzhou Univ, Dept Chem, Fuzhou 350002, Peoples R China
关键词
chemiluminescence; L-arginine; L-lysine; pressurized CEC;
D O I
10.1002/elps.200700327
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A system of off-column coaxial flow chemiluminescence (CL) detection coupled to pressurized CEC (pCEC) was described. The interface utilized a reactor that introduced post-column CL reagent into the capillary effluents in a sheathing flow profile. To compare and evaluate band broadening of analytes caused by the detector, the typical CL compounds luminol and N-(4-aminobutyl)-N-ethylisoluminol (ABEI) were separated and detected by pCEC or capillary HPLC (cHPLC) coupled to CL and UV detector, respectively. The results demonstrated that the band broadening caused by off-column detection interface was minimized due to the fast kinetic nature of the CL reaction. With the proposed pCEC-CL system, the detection limits of luminol and ABEI were 1.0 x 10(-8) and 8.0 x 10(-8) mol/L, respectively, which were approximately 100-fold more sensitive than those obtained with UV absorption. In addition, separation and detection of the ABEI-labeled L-lySine (L-Lys) and L-arginine (L-Arg) were accomplished by pCEC-CL method based on the principle of ABEI-potassium ferricyanide-alkaline medium CL reaction system. Under the optimum conditions, good results could be achieved compared with pCEC-UV.
引用
收藏
页码:401 / 409
页数:9
相关论文
共 43 条
[1]  
Bailey CG, 2000, ELECTROPHORESIS, V21, P3081, DOI 10.1002/1522-2683(20000901)21:15<3081::AID-ELPS3081>3.0.CO
[2]  
2-R
[3]   Analysis of triazines by capillary electrochromatography/electrospray ionization-mass spectrometry using a low-flow sheath liquid interface [J].
Chang, Chia-Hao ;
Chen, Chao-Jung ;
Chuang, Yu-Chieh ;
Her, Guor-Rong .
ELECTROPHORESIS, 2006, 27 (21) :4303-4311
[4]   END-COLUMN CHEMILUMINESCENCE DETECTOR FOR CAPILLARY ELECTROPHORESIS [J].
DADOO, R ;
SETO, AG ;
COLON, LA ;
ZARE, RN .
ANALYTICAL CHEMISTRY, 1994, 66 (02) :303-306
[5]  
Dadoo R., 1992, J HIGH RES CHROMATOG, V15, P133
[6]   Influence of pressure upon coupling pressurized capillary electrochromatography with nuclear magnetic resonance spectroscopy [J].
Gfrörer, P ;
Tseng, LH ;
Rapp, E ;
Albert, K ;
Bayer, E .
ANALYTICAL CHEMISTRY, 2001, 73 (14) :3234-3239
[7]   INVESTIGATION OF INSTRUMENT PARAMETERS FOR THE APPLICATION OF PEROXYOXALATE CHEMI-LUMINESCENCE DETECTION TO MICROBORE CHROMATOGRAPHY [J].
GRAYESKI, ML ;
WEBER, AJ .
ANALYTICAL LETTERS PART A-CHEMICAL ANALYSIS, 1984, 17 (13) :1539-1552
[8]  
Hilmi A, 2000, ELECTROPHORESIS, V21, P1395, DOI 10.1002/(SICI)1522-2683(20000401)21:7<1395::AID-ELPS1395>3.3.CO
[9]  
2-3
[10]   On-line chemiluminescence detection for capillary lan analysis [J].
Huang, B ;
Li, JJ ;
Zhang, L ;
Cheng, JK .
ANALYTICAL CHEMISTRY, 1996, 68 (14) :2366-2369