Effect of incorrect use of dry powder inhalers on management of patients with asthma and COPD

被引:429
作者
Lavorini, Federico [2 ]
Magnan, Antoine [1 ,3 ,4 ]
Dubus, Jean Christophe [5 ,6 ]
Voshaar, Thomas [7 ]
Corbetta, Lorenzo [2 ]
Broeders, Marielle [8 ]
Dekhuijzen, Richard [8 ]
Sanchis, Joaquin [9 ]
Viejo, Jose L. [10 ]
Barnes, Peter [11 ]
Corrigan, Chris [12 ]
Levy, Mark [13 ]
Crompton, Graham K.
机构
[1] Univ Nantes, Fac Med, Inst Thorax, F-44000 Nantes, France
[2] Univ Florence, Unite Funz Med Resp, I-50121 Florence, Italy
[3] INSERM, U533, F-44000 Nantes, France
[4] CHU Nantes, Serv Pneumol, Inst Thorax, F-44000 Nantes, France
[5] Univ Mediterranee, Fac Med, EA 3287, Marseille, France
[6] Unite Med Infantile, Marseille, France
[7] Krankenhaus Bethanien, Moers, Germany
[8] Univ Med Ctr, Nijmegen, Netherlands
[9] Univ Autonoma Barcelona, Hosp Santa Creuide St Pau, Dept Pneumol, Barcelona, Spain
[10] Hosp Gen Yague, Burgos, Spain
[11] Univ London Imperial Coll Sci Technol & Med, Natl Heart & Lung Inst, London, England
[12] Kings Coll London, Sch Med, Dept Asthma Allergy & Resp Sci, London, England
[13] Univ Edinburgh, GP Sect, Div Community Hlth Sci, Edinburgh EH8 9YL, Midlothian, Scotland
基金
英国医学研究理事会;
关键词
dry powder inhaler; inhalation technique; asthma; COPD;
D O I
10.1016/j.rmed.2007.11.003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Incorrect usage of inhaler devices might have a major influence on the clinical effectiveness of the delivered drug. This issue is poorly addressed in management guidelines. Methods: This article presents the results of a systematic literature review of studies evaluating incorrect use of established dry powder inhalers (DPIs) by patients with asthma or chronic obstructive pulmonary disease (COPD). Results: Overall, we found that between 4% and 94% of patients, depending on the type of inhaler and method of assessment, do not use their inhalers correctly. The most common errors made included failure to exhale before actuation, failure to breath-hold after inhalation, incorrect positioning of the inhaler, incorrect rotation sequence, and failure to execute a forceful and deep inhalation. Inefficient DPI technique may lead to insufficient drug delivery and hence to insufficient lung deposition. As many as 25% of patients have never received verbal inhaler technique instruction, and for those that do, the quality and duration of instruction is not adequate and not reinforced by follow-up checks. Conclusions: This review demonstrates that incorrect DPI technique with established DPIs is common among patients with asthma and COPD, and suggests that poor inhalation technique has detrimental consequences for clinical efficacy. Regular assessment and reinforcement of correct inhalation technique are considered by health professionals and caregivers to be an essential component of successful asthma management. Improvement of asthma and COPD management could be achieved by new DPIs that are easy to use correctly and are forgiving of poor inhalation technique, thus ensuring more successful drug delivery. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:593 / 604
页数:12
相关论文
共 53 条
  • [1] AIOLFI S, 2003, RASS PATOL APPARATO, V18, P283
  • [2] BOTTING C, 2003, NZMJ, V116, P1709
  • [3] BROCKLEBANK D, 2001, BMJ-BRIT MED J, V323, P1
  • [4] Inhalation profiles in asthmatics and COPD patients: Reproducibility and effect of instruction
    Broeders, MEAC
    Molema, J
    Hop, WCJ
    Folgering, HTM
    [J]. JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 2003, 16 (02): : 131 - 141
  • [5] Campos A, 1998, Allergol Immunopathol (Madr), V26, P47
  • [6] CANESSA P, 2003, RASS PATOL APPARATO, V18, P455
  • [7] Carrion Valero F, 2000, Arch Bronconeumol, V36, P236
  • [8] Is inhalation rate important for a dry powder inhaler? using the In-Check Dial to identify these rates
    Chrystyn, H
    [J]. RESPIRATORY MEDICINE, 2003, 97 (02) : 181 - 187
  • [9] Cimas J E, 1999, Arch Bronconeumol, V35, P15
  • [10] CINTI C, 2003, RASS PATOL APPARATO, V18, P32