Seismic retrofit of welded steel moment connections with highly composite floor slabs

被引:23
|
作者
Sung-Yong, Kim [1 ]
Cheol-Ho, Lee [1 ]
机构
[1] Seoul Natl Univ, Dept Architecture & Architectural Engn, Seoul 151742, South Korea
关键词
Seismic retrofit; Connections; Steel moment frames; Slab effect; Haunch; Heavy shear tab; RESISTING CONNECTIONS; PERFORMANCE; HAUNCH; BEHAVIOR; DESIGN;
D O I
10.1016/j.jcsr.2017.09.010
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In the 1994 Northridge earthquake, connection damage initiated from the beam bottom flange was prevalent in welded steel moment frames. The composite action due to the presence of a concrete floor slab was speculated as one of the critical causes of the prevalent bottom flange fracture. Close review of past experimental studies recently conducted by the authors clearly indicated that conventional steel moment connections with highly composite slabs are much more vulnerable to the bottom flange fracture: In this study, three seismic retrofit schemes are presented for welded steel moment connections with highly composite floor slabs typical of existing steel moment frames in Korea. Because top flange modification of existing beams is not feasible due to the presence of a concrete floor slab, beam bottom flange or web modifications by using welded triangular or straight haunch and heavy shear tab were cyclically tested. Test results of this study showed that all the retrofit schemes used are effective in eliminating the detrimental effect caused by high composite action and can ensure excellent connection plastic rotation exceeding 4% rad. Side effects resulting from retrofit as well as design recommendations are also discussed. (C) 2017 Published by Elsevier Ltd.
引用
收藏
页码:62 / 68
页数:7
相关论文
共 50 条
  • [41] Displacement-restraint bracing for seismic retrofit of steel moment frames
    Hou, Xingguo
    Tagawa, Hiroshi
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2009, 65 (05) : 1096 - 1104
  • [42] Seismic reliability of special moment steel frames with welded connections: II (vol 125, pg 372, 1999)
    Song, JL
    Ellingwood, BR
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1999, 125 (11): : 1354 - 1354
  • [43] Seismic performance of pre-northridge welded steel moment connections to built-up box columns
    Kim, Taejin
    Stojadinovic, Bozidar
    Whittaker, Andrew S.
    JOURNAL OF STRUCTURAL ENGINEERING, 2008, 134 (02) : 289 - 299
  • [44] Seismic rehabilitation design of steel moment connection with welded haunch
    Yu, QS
    Uang, CM
    Gross, J
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2000, 126 (01): : 69 - 78
  • [45] A connection model for the seismic analysis of welded steel moment frames
    Gross, JL
    ENGINEERING STRUCTURES, 1998, 20 (4-6) : 390 - 397
  • [46] Moment redistribution in continuous profiled steel - concrete composite slabs
    Lee, LH
    Quek, ST
    Ang, KK
    MAGAZINE OF CONCRETE RESEARCH, 2001, 53 (05) : 301 - 309
  • [47] Seismic performance of reinforced concrete eccentric beam-column connections with floor slabs
    Shin, MS
    LaFave, JM
    ACI STRUCTURAL JOURNAL, 2004, 101 (03) : 403 - 412
  • [48] Optimized seismic retrofit of steel-concrete composite buildings
    Papavasileiou, Georgios S.
    Charmpis, Dimos C.
    Lagaros, Nikos D.
    ENGINEERING STRUCTURES, 2020, 213 (213)
  • [49] Experimental results for seismic resistant steel moment frame connections
    Roeder, CW
    Foutch, DA
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1996, 122 (06): : 581 - 588
  • [50] Ductile moment connections for steel frames subjected to seismic loading
    Richard, RM
    Allen, CJ
    Partridge, JE
    INNOVATION IN ENGINEERING FOR SEISMIC REGIONS, 1997, : 53 - 59