Monte Carlo Simulation and Collimator Optimization for Tomographic Gamma Scanning

被引:0
|
作者
Zhang, Jinzhao [1 ]
Tuo, Xianguo [2 ,3 ]
Wang, Qibiao [2 ,3 ]
Leng, Yangchun [2 ,3 ]
Shi, Rui [2 ,3 ]
机构
[1] Natl Ocean Technol Ctr, Tianjin, Peoples R China
[2] Chengdu Univ Technol, Coll Nucl Technol & Automat Engn, Chengdu, Sichuan, Peoples R China
[3] Sichuan Univ Sci & Engn, Coll Chem & Environm Engn, Zigong, Peoples R China
关键词
WASTE DRUMS; ASSAY;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We present the design and optimization of a Tomographic Gamma Scanning (TGS) collimator using Monte Carlo methods. In these simulations, an accurate TGS model was built and the radius, depth and shape of the TGS collimator were optimized. The simulation results reveal that the optimal collimator aperture radius and depth for this system are 3.1 cm and 18.6 cm, respectively, achieved when the full width at half maximum (FWHM) is 26.7 cm. Also, a rotated 30 hexagon is found to be the optimal shape. Our TGS design shows significantly improved performance.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Monte Carlo simulation of the dynamic collimator in a pencil beam scanning system
    Almeida, I. P.
    Sure, M.
    Vilches-Freixas, G.
    Cooley, J.
    Zwart, T.
    Langenegger, A.
    Verhaegen, F.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S985 - S986
  • [2] A Monte Carlo Simulation Study of Optimization for Collimator in a Pixelated SPECT Camera
    Telikani, Zeinab
    Sadremomtaz, Alireza
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2019, 50 (01) : 163 - 170
  • [3] Optimization of pinhole collimator for small animal SPECT using Monte Carlo simulation
    Song, TY
    Choi, Y
    Chung, YH
    Jung, JH
    Choe, YS
    Lee, KH
    Kim, SE
    Kim, BT
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (03) : 327 - 332
  • [4] Optimization of pinhole collimator for small animal SPECT using Monte Carlo simulation
    Song, TY
    Choi, Y
    Chung, YH
    Jung, JH
    Choe, YS
    Lee, KH
    Kim, SE
    Kim, BT
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 811 - 815
  • [5] Optimization of a High-resolution Collimator for a CdTe Detector: Monte Carlo Simulation Studies
    Lee, Young-Jin
    Ryu, Hyun-Ju
    Cho, Hyo-Min
    Lee, Seung-Wan
    Choi, Yu-Na
    Kim, Hee-Joung
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2012, 60 (05) : 862 - 868
  • [6] Optimization of a high-resolution collimator for a CdTe detector: Monte Carlo simulation studies
    Young-Jin Lee
    Hyun-Ju Ryu
    Hyo-Min Cho
    Seung-Wan Lee
    Yu-Na Choi
    Hee-Joung Kim
    Journal of the Korean Physical Society, 2012, 60 : 862 - 868
  • [7] Monte Carlo Simulation of a Micro-multileaf Collimator
    Gonzalez, W.
    Lallena, A. M.
    Alfonso, R.
    5TH LATIN AMERICAN CONGRESS ON BIOMEDICAL ENGINEERING (CLAIB 2011): SUSTAINABLE TECHNOLOGIES FOR THE HEALTH OF ALL, PTS 1 AND 2, 2013, 33 (1-2): : 1252 - +
  • [8] Monte Carlo Simulation on Breast Cancer Detection Using Wire Mesh Collimator Gamma Camera
    Saripan, M. Iqbal
    Saad, Wira Hidayat Mohd
    Hashim, Suhairul
    Mahmud, Rozi
    Nordin, Abdul Jalil
    Mahdi, Mohd Adzir
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (03) : 1321 - 1324
  • [9] Optimization of Collimator Design in HiReSPECT II: a Monte Carlo Study
    Mirdoraghi, M.
    Fard, B. Teimourian
    Kochebina, O.
    Mahani, H.
    Ay, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S699 - S699
  • [10] Effects of collimator backscatter in an Elekta linac by Monte Carlo simulation
    Kairn, T.
    Crowe, S. B.
    Poole, C. M.
    Fielding, A. L.