Chemical composition and heterogeneity of Wild 2 cometary particles determined by synchrotron X-ray fluorescence

被引:31
|
作者
Lanzirotti, A. [1 ]
Sutton, S. R. [1 ,2 ]
Flynn, G. J. [3 ]
Newville, A. [1 ]
Rao, W. [4 ]
机构
[1] Univ Chicago, Ctr Adv Radiat Sources, Chicago, IL 60637 USA
[2] Univ Chicago, Dept Geophys Sci, Chicago, IL 60637 USA
[3] SUNY Coll Plattsburgh, Dept Phys, Plattsburgh, NY 12901 USA
[4] Univ Georgia, Savannah River Ecol Lab, Aiken, SC 29808 USA
关键词
D O I
10.1111/j.1945-5100.2008.tb00617.x
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
Seven cometary dust particle tracks in Stardust aerogel were studied using synchrotron X-ray fluorescence methods at the National Synchrotron Light Source (NY) and Advanced Photon Source (IL). Elemental maps were produced for each of the tracks and elemental abundances for 156 individual fragments within these tracks were determined. Whole-track elemental abundances were inferred by summing the elemental masses for the fragments in each track and scaling by the ratio of total Fe in the map and total Fe in the fragments. In general, whole-track and terminal-particle abundances are dissimilar. The total Fe masses ranged from 4 to 2200 pg, corresponding to impactors in the size range of 2.7 to 22 mu m if Fe abundances are equal to the chondritic value. Systematic variations in element abundance with fragment distance from the aerogel entry point were generally subtle but were pronounced in one track (C2115,19). In this track, Zn/Fe was about three orders of magnitude higher at the top, Cr/Fe was two orders of magnitude higher at the bottom, and S was relatively uniform. Compositional convergence data showed that typically analysis of similar to 10 fragments was needed to reach convergent whole-track abundance. Zinc was an exception, showing nonconvergent profiles and steps due to the presence of rare, high-Zn fragments. The resulting whole-track elemental abundances show diverse patterns that are generally chondritic (i.e., within a factor of three of CI abundances) with some exceptions, notably depletions in S and enrichments in the moderately volatile elements Cu, Zn, and Ga. Enrichments in large ion lithophile elements relative to Fe were observed in one track. Correlation matrices showed several strong elemental correlations, notably selenium associated with sulfur (sulfides), a ubiquitous correlation of the first-row transition metals Cr, Mn, and Fe attributed to the presence of pyroxene, and enrichments of gallium associated with calcium, likely affiliated with Mg-Al glass.
引用
收藏
页码:187 / 213
页数:27
相关论文
共 50 条
  • [31] Techniques for depth heterogeneity identification in X-ray fluorescence
    Trojek, T.
    Cechak, T.
    Mtisilek, L.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 263 (01): : 76 - 78
  • [32] Preliminary study on the chemical mapping of individual fluid inclusion by synchrotron X-ray fluorescence microprobe
    Hayashi, K
    Iida, A
    RESOURCE GEOLOGY, 2001, 51 (03) : 259 - 262
  • [33] Correlative organelle fluorescence microscopy and synchrotron X-ray chemical element imaging in single cells
    Roudeau, Stephane
    Carmona, Asuncion
    Perrin, Laura
    Ortega, Richard
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (27) : 6979 - 6991
  • [34] Correlative organelle fluorescence microscopy and synchrotron X-ray chemical element imaging in single cells
    Stéphane Roudeau
    Asuncion Carmona
    Laura Perrin
    Richard Ortega
    Analytical and Bioanalytical Chemistry, 2014, 406 : 6979 - 6991
  • [35] Using x-ray analogs of elements to be determined in the x-ray fluorescence analysis of liquid samples
    M. N. Filippov
    A. A. Mukhanova
    T. A. Kupriyanova
    O. I. Lyamina
    Journal of Analytical Chemistry, 2008, 63 : 756 - 761
  • [36] Using x-ray analogs of elements to be determined in the x-ray fluorescence analysis of liquid samples
    Filippov, M. N.
    Mukhanova, A. A.
    Kupriyanova, T. A.
    Lyamina, O. I.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2008, 63 (08) : 756 - 761
  • [37] SCANNING X-RAY FLUORESCENCE MICROPROBE WITH SYNCHROTRON RADIATION.
    Gohshi, Yohichi
    Aoki, Sadao
    Iida, Atsuo
    Hayakawa, Shinjiro
    Yamaji, Hironao
    Sakurai, Kenji
    Japanese Journal of Applied Physics, Part 2: Letters, 1987, 26 (08): : 1260 - 1262
  • [38] Synchrotron x-ray fluorescence analysis of gas bubbles in glass
    Romano, C
    Dingwell, DB
    Lechtenberg, F
    PHYSICS AND CHEMISTRY OF GLASSES, 1998, 39 (03): : 181 - 183
  • [39] Scanning Synchrotron X-Ray Fluorescence Microanalysis for Tephrochronological Studies
    Darin, A. V.
    Darin, F. A.
    Sorokoletov, D. S.
    Rakshun, Ya. V.
    Rogozin, D. Yu.
    JOURNAL OF SURFACE INVESTIGATION, 2023, 17 (06): : 1253 - 1257
  • [40] Forensic application of synchrotron radiation X-ray fluorescence analysis
    Nakai, I
    Terada, Y
    Ninomiya, T
    16TH MEETING OF THE INTERNATIONAL ASSOCIATION OF FORENSIC SCIENCES, 2002, : 29 - 34