Sternal reconstruction with titanium plates in complicated sternal dehiscence

被引:74
|
作者
Voss, Bernhard [1 ]
Bauernschmitt, Robert [1 ]
Will, Albrecht [2 ]
Krane, Markus [1 ]
Kroess, Ruth [1 ]
Brockmann, Gernot [1 ]
Libera, Paul [1 ]
Lange, Ruediger [1 ]
机构
[1] Clin Tech Univ, Dept Cardiovasc Surg, German Heart Ctr, D-80636 Munich, Germany
[2] Clin Tech Univ, German Heart Ctr, Dept Radiol, D-80636 Munich, Germany
关键词
sternal dehiscence; rigid plate fixation; osteosynthesis;
D O I
10.1016/j.ejcts.2008.03.030
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Sternal dehiscence after median sternotomy can be a challenging problem in case of multiple fractures or infection. The use of titanium plates is a promising approach for sternal reconstruction. Methods: Titanium plate fixation was used in 15 patients (67 +/- 5.9 years, 171 +/- 8.2 cm, 93.6 +/- 14.9 kg, body mass index 32 +/- 5 kg/m(2)) with unstable thorax after failed attempts of sternal closure and patients in whom failure of conventional rewiring would be expected due to one or more serious risk factors (e.g. multiple fractures or loss of sternum, excessive overweight). In six patients, one of whom had an infection, the Synthes(TM) Titanium Sternal Fixation System was used as transverse plate fixation (series 1). In nine other patients, longitudinal titanium plating of the sternum was performed with 2.4 mm Synthes locking reconstruction plates, which were cross-connected by wires (series 2). In six of these patients the cross-connection was reinforced by additional short transverse plates. In series 2, sternal instability was complicated by multiple fragments of sternum (n = 8) and/or infection (n = 3). In case of infection, initial debridement was performed with consecutive antibiotic and topical negative pressure therapy (median 13 days). Clinical examination was done 3-12 months postoperatively. Results: Mean operation time was 133 +/- 21 min (series 1) and 110 +/- 12 min (series 2). Transverse plating required more extensive mobilization of pectoral muscle. All patients had an uneventful early postoperative course and were extubated 5.1 +/- 5.9 h (median 4 h) after surgery. Postoperatively, all patients had a stable thorax, but in the tong-term three patients from series 1 complained of plate-related pain during breathing, with the subsequent need of plate removal. One multi morbid patient from series 1 died on the 31st postoperative day. The cause of death was not related to the sternal plate refixation. Conclusion: Titanium plate fixation is an effective method to stabilize complicated sternal dehiscence. The longitudinal plating technique is easier to apply and seems to be associated with fewer complications. (C) 2008 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:139 / 145
页数:7
相关论文
共 50 条
  • [41] Failure analysis of explanted sternal wires
    Shih, CM
    Su, YY
    Lin, SJ
    Shih, CC
    BIOMATERIALS, 2005, 26 (14) : 2053 - 2059
  • [42] The Impact of Gender and Age in Obese Patients on Sternal Instability and Deep-Sternal-Wound-Healing Disorders after Median Sternotomy
    Braun, Christian
    Schroeter, Filip
    Laux, Magdalena Lydia
    Kuehnel, Ralf-Uwe
    Ostovar, Roya
    Hartrumpf, Martin
    Necaev, Anna-Maria
    Sido, Viyan
    Albes, Johannes Maximilian
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (13)
  • [43] Sternal wound complications - Incidence, microbiology and risk factors'
    Stahle, E
    Tammelin, A
    Bergstrom, R
    Hambreus, A
    Nystrom, SO
    Hansson, HE
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1997, 11 (06) : 1146 - 1153
  • [44] The Importance of Early Flap Coverage in Deep Sternal Wounds
    Lo, Steven
    Hutson, Kristian
    Hallam, Marc-James
    Soldin, Mark
    ANNALS OF PLASTIC SURGERY, 2014, 73 (05) : 588 - 590
  • [45] Failure analysis of the fractured wires in sternal perichronal loops
    Chao, Jesus
    Voces, Roberto
    Pena, Carmen
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2011, 4 (07) : 1004 - 1010
  • [46] A Novel Sternal Closure Technique With Implants Suitable for Complex Dehiscences
    de Bucourt, Maximilian
    Swierzy, Marc
    Ismail, Mahmoud
    Gregor, Jan
    Webler, Markus
    Rueckert, Jens-Carsten
    SURGICAL INNOVATION, 2010, 17 (04) : 353 - 355
  • [47] Prospective evaluation of a new sternal closure method with thermoreactive clips
    Negri, A
    Manfredi, J
    Terrini, A
    Rodella, G
    Bisleri, G
    El Quarra, S
    Muneretto, C
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2002, 22 (04) : 571 - 575
  • [48] Current treatment and outcomes of traumatic sternal fracturesa systematic review
    Klei, Dorine S.
    de Jong, Mirjam B.
    Oner, F. Cumhur
    Leenen, Luke P. H.
    van Wessem, Karlijn J. P.
    INTERNATIONAL ORTHOPAEDICS, 2019, 43 (06) : 1455 - 1464
  • [49] Surgical management of traumatic isolated sternal fracture and manubriosternal dislocation
    Divisi, Duilio
    Di Leonardo, Gabriella
    Crisci, Roberto
    JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2013, 75 (05) : 824 - 829
  • [50] Comparison of postoperative exercise capacity of patients who underwent sternal closure with SternaLock Blu and those with traditional sternal wire closure following cardiovascular surgery via sternotomy
    Tamura, Kiyoshi
    Sakurai, Shogo
    INDIAN JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2023, 39 (05) : 471 - 475