Sternal reconstruction with titanium plates in complicated sternal dehiscence

被引:74
|
作者
Voss, Bernhard [1 ]
Bauernschmitt, Robert [1 ]
Will, Albrecht [2 ]
Krane, Markus [1 ]
Kroess, Ruth [1 ]
Brockmann, Gernot [1 ]
Libera, Paul [1 ]
Lange, Ruediger [1 ]
机构
[1] Clin Tech Univ, Dept Cardiovasc Surg, German Heart Ctr, D-80636 Munich, Germany
[2] Clin Tech Univ, German Heart Ctr, Dept Radiol, D-80636 Munich, Germany
关键词
sternal dehiscence; rigid plate fixation; osteosynthesis;
D O I
10.1016/j.ejcts.2008.03.030
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Sternal dehiscence after median sternotomy can be a challenging problem in case of multiple fractures or infection. The use of titanium plates is a promising approach for sternal reconstruction. Methods: Titanium plate fixation was used in 15 patients (67 +/- 5.9 years, 171 +/- 8.2 cm, 93.6 +/- 14.9 kg, body mass index 32 +/- 5 kg/m(2)) with unstable thorax after failed attempts of sternal closure and patients in whom failure of conventional rewiring would be expected due to one or more serious risk factors (e.g. multiple fractures or loss of sternum, excessive overweight). In six patients, one of whom had an infection, the Synthes(TM) Titanium Sternal Fixation System was used as transverse plate fixation (series 1). In nine other patients, longitudinal titanium plating of the sternum was performed with 2.4 mm Synthes locking reconstruction plates, which were cross-connected by wires (series 2). In six of these patients the cross-connection was reinforced by additional short transverse plates. In series 2, sternal instability was complicated by multiple fragments of sternum (n = 8) and/or infection (n = 3). In case of infection, initial debridement was performed with consecutive antibiotic and topical negative pressure therapy (median 13 days). Clinical examination was done 3-12 months postoperatively. Results: Mean operation time was 133 +/- 21 min (series 1) and 110 +/- 12 min (series 2). Transverse plating required more extensive mobilization of pectoral muscle. All patients had an uneventful early postoperative course and were extubated 5.1 +/- 5.9 h (median 4 h) after surgery. Postoperatively, all patients had a stable thorax, but in the tong-term three patients from series 1 complained of plate-related pain during breathing, with the subsequent need of plate removal. One multi morbid patient from series 1 died on the 31st postoperative day. The cause of death was not related to the sternal plate refixation. Conclusion: Titanium plate fixation is an effective method to stabilize complicated sternal dehiscence. The longitudinal plating technique is easier to apply and seems to be associated with fewer complications. (C) 2008 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:139 / 145
页数:7
相关论文
共 50 条
  • [31] Is Allogeneic Blood Transfusion a Risk Factor for Sternal Dehiscence Following Cardiac Surgery? A Prospective Observational Study
    Vymazal, Tomas
    Horacek, Michal
    Durpekt, Radim
    Hladikova, Marie
    Cvachovec, Karel
    INTERNATIONAL HEART JOURNAL, 2009, 50 (05) : 601 - 607
  • [32] Comparison of figure of eight and traditional simple wire closure method to prevent dehiscence after sternal closure
    Asghar, Aleezay
    Talha, Khawaja Muhammad
    Amanullah, Muneer
    Shahabuddin, Syed
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2020, 70 (11) : 2001 - 2006
  • [33] Outcomes in the management of sternal dehiscence by plastic surgery - A ten-year review in one university center
    Landes, Genevieve
    Harris, Patrick G.
    Sampalis, John S.
    Brutus, Jean-Paul
    Cordoba, Carlos
    Ciaburro, Hugo
    Bernier, Christina
    Nikolis, Andreas
    ANNALS OF PLASTIC SURGERY, 2007, 59 (06) : 659 - 666
  • [34] The role of the unilateral pectoralis major muscle flap in the treatment of deep sternal wound infection and dehiscence COMMENT
    Coltro, Pedro S.
    Farina Junior, Jayme A.
    JOURNAL OF CARDIAC SURGERY, 2022, 37 (08) : 2315 - 2316
  • [35] Potential risk of sternal wires
    Shih, CC
    Shih, CM
    Su, YY
    Lin, SJ
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2004, 25 (05) : 812 - 818
  • [36] Broken and scattered sternal wires
    Alihanoglu, Yusuf Izzettin
    Kilic, Ismail Dogu
    Yildiz, Bekir Serhat
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2013, 44 (05) : E344 - E344
  • [37] Does Elective Sternal Plating Combined with Steel Wire Reduce Sternal Complication Rates in Patients with Obesity?
    Celik, Ersin
    Cora, Ahmet Rifki
    BRAZILIAN JOURNAL OF CARDIOVASCULAR SURGERY, 2023, 38 (03) : 367 - 374
  • [38] Prevention of sternal dehiscence with the Sternum External Fixation (Stern-E-Fix) corset – a randomized trial in 750 patients
    Lachmandath S Tewarie
    Ares K Menon
    Nima Hatam
    Andrea Amerini
    Ajay K Moza
    Rüdiger Autschbach
    Andreas Goetzenich
    Journal of Cardiothoracic Surgery, 7
  • [39] Prevention of sternal dehiscence with the Sternum External Fixation (Stern-E-Fix) corset - a randomized trial in 750 patients
    Tewarie, Lachmandath S.
    Menon, Ares K.
    Hatam, Nima
    Amerini, Andrea
    Moza, Ajay K.
    Autschbach, Ruediger
    Goetzenich, Andreas
    JOURNAL OF CARDIOTHORACIC SURGERY, 2012, 7 : 85
  • [40] Surgical fixation of sternal fractures: locked plate fixation by low-profile titanium plates-surgical safety through depth limited drilling
    Schulz-Drost, Stefan
    Mauerer, Andreas
    Grupp, Sina
    Hennig, Friedrich F.
    Blanke, Matthias
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (01) : 133 - 139