Evaluation of Pentacam-Scheimpflug imaging of anterior segment parameters in patients with pseudoexfoliation syndrome and pseudoexfoliative glaucoma

被引:31
作者
Doganay, Selim [1 ]
Tasar, Ahmet
Cankaya, Cem
Firat, Penpe Gul
Yologlu, Saim [2 ]
机构
[1] Inonu Univ, Sch Med, Turgut Ozal Med Ctr, Dept Ophthalmol, TR-44280 Malatya, Turkey
[2] Inonu Univ, Sch Med, Dept Biostat, TR-44280 Malatya, Turkey
关键词
anterior chamber angle; anterior chamber depth; central corneal thickness; corneal volume; glaucoma; pseudoexfoliation; pupil; Scheimpflug imaging system; OPTICAL COHERENCE TOMOGRAPHY; OPEN-ANGLE GLAUCOMA; INTRAOCULAR-LENS IMPLANTATION; CORNEAL THICKNESS; EXFOLIATION SYNDROME; CHAMBER DEPTH; ULTRASOUND BIOMICROSCOPY; CATARACT-SURGERY; CLOSURE GLAUCOMA; EYES;
D O I
10.1111/j.1444-0938.2011.00691.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: The aim was to evaluate anterior segment parameters in patients with pseudoexfoliation syndrome (PXS) or pseudoexfoliative glaucoma (PXG) with the Pentacam-Scheimpflug imaging system. Methods: Eighty eyes of 53 patients with PXS (Group 1), 80 eyes of 57 patients with PXG (Group 2) and 80 eyes of 45 control cases (Group 3) were included in the study. Anterior chamber depth, volume (ACV), angle (ACA) width, central corneal thickness (CCT), central 3.0, 5.0 and 7.0 mm corneal volumes and pupil diameters were compared between groups. Results: Although anterior chamber depths in the PXG group were significantly lower than the control group (p < 0.05), there was no statistically significant difference between the PXS group and the control group in means of anterior chamber depth values (p > 0.05). There were no statistically significant differences among PXS, PXG and the control group in mean values of ACV, ACA width, CCT, pupil diameters and central 3.0, 5.0 and 7.0 mm corneal volume (p > 0.05). Conclusions: The anterior chamber depths of PXG patients were lower than those of healthy individuals. Although the difference in anterior chamber depth between PXG patients and normal patients was statistically significant, this finding is unlikely to be of clinical significance. The anterior chamber depths of PXS patients were similar to those of healthy individuals. There were no significant differences in the means of ACV, ACA width, CCT, pupil diameter and corneal volume values on central 3.0, 5.0 and 7.0 mm among patients with PXS, PXG and healthy individuals.
引用
收藏
页码:218 / 222
页数:5
相关论文
共 38 条
  • [1] Pseudoexfoliation in the Reykjavik Eye Study: prevalence and related ophthalmological variables
    Arnarsson, Arsaell
    Damji, Karim F.
    Sverrisson, Thordur
    Sasaki, Hiroshi
    Jonasson, Fridbert
    [J]. ACTA OPHTHALMOLOGICA SCANDINAVICA, 2007, 85 (08): : 822 - 827
  • [2] A HISTOPATHOLOGIC STUDY OF IRIS CHANGES IN PSEUDOEXFOLIATION SYNDROME
    ASANO, N
    SCHLOTZERSCHREHARDT, U
    NAUMANN, GOH
    [J]. OPHTHALMOLOGY, 1995, 102 (09) : 1279 - 1290
  • [3] Central corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetry
    Barkana, Y
    Gerber, Y
    Elbaz, U
    Schwartz, S
    Ken-Dror, G
    Avni, I
    Zadok, D
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (09) : 1729 - 1735
  • [4] ANTERIOR-CHAMBER DEPTH IN EYES WITH PSEUDOEXFOLIATION
    BARTHOLOMEW, RS
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 1980, 64 (05) : 322 - 323
  • [5] Central corneal thickness determined with optical coherence tomography in various types of glaucoma
    Bechmann, M
    Thiel, MJ
    Roesen, B
    Ullrich, S
    Ulbig, MW
    Ludwig, K
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2000, 84 (11) : 1233 - 1237
  • [6] Comparison of anterior segment optical coherence tomography and ultrasound biomicroscopy for assessment of the anterior segment
    Dada, Tanuj
    Sihota, Ramanjit
    Gadia, Ritu
    Aggarwal, Anand
    Mandal, Subrata
    Gupta, Viney
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (05) : 837 - 840
  • [7] Anterior segment optical coherence tomography for evaluation of changes in anterior chamber angle and depth after intraocular lens implantation in eyes with glaucoma
    Dawczynski, J.
    Koenigsdoerffer, E.
    Augsten, R.
    Strobel, J.
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2007, 17 (03) : 363 - 367
  • [8] Gohdo T, 1997, BRIT J OPHTHALMOL, V81, P706
  • [9] HAHNENBERGER R, 1984, ACTA OPHTHALMOL, V62, P135
  • [10] Morphological study of corneal endothelium and corneal thickness in pseudoexfoliation syndrome
    Inoue, K
    Okugawa, K
    Oshika, T
    Amano, S
    [J]. JAPANESE JOURNAL OF OPHTHALMOLOGY, 2003, 47 (03) : 235 - 239