Colour Doppler sonography of hepatic haemangiomas with arterioportal shunts

被引:16
|
作者
Lim, K. J. [1 ,2 ,3 ]
Kim, K. W. [1 ,2 ]
Jeong, W. K. [1 ,2 ,4 ]
Kim, S. Y. [1 ,2 ,5 ]
Jang, Y. J. [1 ,2 ,6 ]
Yang, S. [7 ]
Lee, J. J. [8 ]
机构
[1] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Radiol, Seoul 138736, South Korea
[2] Univ Ulsan, Coll Med, Asan Med Ctr, Res Inst Radiol, Seoul 138736, South Korea
[3] Hallym Univ, Kangdong Sacred Heart Hosp, Coll Med, Dept Radiol, Seoul, South Korea
[4] Hanyang Univ, Guri Hosp, Dept Radiol, Gyonggi Do, South Korea
[5] Seoul Natl Univ, Bundang Hosp, Dept Radiol, Gyeonggi Do, South Korea
[6] Kyungpook Natl Univ Hostpital, Dept Radiol, Taegu, South Korea
[7] Dan Kook Univ, Coll Med, Chungnam, South Korea
[8] Catholic Univ Korea, Dept Digital Media, Gyeonggi Do, South Korea
关键词
FOCAL NODULAR HYPERPLASIA; LIVER; CT; DIAGNOSIS; US;
D O I
10.1259/bjr/96605786
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To determine the frequency of intratumoural flow and peritumoural hepatofugal portal flow using colour Doppler sonography (CDS) on hepatic haemangiomas with arterioportal shunt (APS), and to investigate possible factors that may affect the capability of CDS to depict such findings. Methods: The study included 45 patients (35 men, 10 women; mean age, 56 years) with hepatic haemangiomas with APS on CT or MRI. Locating the tumour on greyscale sonography, the depth, size and echogenicity of the tumour were evaluated. CT or MR images were evaluated for fatty liver. CDS was performed to determine the presence of intratumoural flow and peritumoural hepatofugal portal flow. Differences in frequency of intratumoural flow and peritumoural hepatofugal portal flow according to the depth, size, echogenicity and fatty liver were evaluated by Student's t-test and Fisher's exact test. Results: On CDS, intratumoural flow and peritumoural hepatofugal portal flow were found in 66.7% and 60%, respectively. The tumour depth was the significant variable that affected the capability of CDS to depict such findings. The frequencies of intratumoural flow and peritumoural hepatofugal portal flow were as high as 88% and 80% for shallow (<= 30 mm) lesions, and they were 40% and 35% for deep (>30 mm) lesions (p=0.0012; p=0.0051). Conclusion: CDS can commonly depict intratumoural flow and peritumoural hepatofugal portal flow in patients with hepatic haemangiomas with APS. Therefore, CDS should be routinely performed when an incidental mass is encountered during the screening sonography, especially when the lesion is shallow.
引用
收藏
页码:142 / 146
页数:5
相关论文
共 50 条
  • [1] Hepatic arterioportal shunts: Dynamic CT and MR features
    Choi, BI
    Lee, KH
    Han, JK
    Lee, JM
    KOREAN JOURNAL OF RADIOLOGY, 2002, 3 (01) : 1 - 15
  • [2] Hereditary haemorrhagic teleangiectasia: hepatic lesions demonstrated with colour Doppler and power Doppler sonography
    Chou, YH
    Tiu, CM
    Hsu, CC
    Chiou, HJ
    Hsieh, SL
    Teng, MMH
    Yu, C
    EUROPEAN JOURNAL OF RADIOLOGY, 2000, 34 (01) : 52 - 56
  • [3] CT and MRI imaging and interpretation of hepatic arterioportal shunts
    Wang, Qiushi
    Koniaris, Leonidas G.
    Milgrom, Daniel P.
    Patel, Aash
    Hu, Maoqing
    Cui, Enming
    Deng, Yu
    Akisik, Fatih
    TRANSLATIONAL GASTROENTEROLOGY AND HEPATOLOGY, 2019, 4
  • [4] Colour Doppler sonography in breast tumours: an update
    Delorme, S
    Zuna, I
    Huber, S
    Albert, B
    Bahner, ML
    Junkermann, H
    van Kaick, G
    EUROPEAN RADIOLOGY, 1998, 8 (02) : 189 - 193
  • [5] Colour Doppler sonography in breast tumours: an update
    S. Delorme
    I. Zuna
    S. Huber
    B. Albert
    M. L. Bahner
    H. Junkermann
    G. van Kaick
    European Radiology, 1998, 8 : 189 - 193
  • [6] Colour Doppler ultrasound imaging findings in paediatric periocular and orbital haemangiomas
    Spierer, Oriel
    Neudorfer, Meira
    Leibovitch, Igal
    Stolovitch, Chaim
    Kessler, Ada
    ACTA OPHTHALMOLOGICA, 2012, 90 (08) : 727 - 732
  • [7] Color Doppler Sonography of Intrahepatic Vascular Shunts
    Bertolotto, Michele
    Martinoli, Carlo
    Migaleddu, Vincenzo
    Cernic, Stefano
    Zappetti, Roberta
    JOURNAL OF CLINICAL ULTRASOUND, 2008, 36 (09) : 527 - 538
  • [8] Clinical characteristics of hepatic Arterioportal shunts associated with hepatocellular carcinoma
    Wu, Huiyong
    Zhao, Wei
    Zhang, Jianbo
    Han, Jianjun
    Liu, Shuguang
    BMC GASTROENTEROLOGY, 2018, 18
  • [9] Color Doppler sonography in the diagnosis of neonatal intrahepatic portosystemic shunts
    Valls, E
    Ceres, L
    Urbaneja, A
    Muñoz, R
    Alonso, I
    JOURNAL OF CLINICAL ULTRASOUND, 2000, 28 (01) : 42 - 46
  • [10] Congenital hepatic shunts
    Gallego, C
    Miralles, M
    Marín, C
    Muyor, P
    González, G
    García-Hidalgo, E
    RADIOGRAPHICS, 2004, 24 (03) : 755 - 772