Risk Factors and Outcomes Associated with Intraoperative Fractures during Short-Stem Total Hip Arthroplasty for Osteonecrosis of the Femoral Head

被引:6
|
作者
Malhotra, Rajesh [1 ]
Gupta, Saurabh [1 ]
Gupta, Vivek [2 ]
Manhas, Vikrant [1 ]
机构
[1] All India Inst Med Sci AIIMS, Dept Orthoped, Teaching Block, New Delhi 110029, India
[2] All India Inst Med Sci AIIMS, Dept Community Ophthalmol, New Delhi, India
关键词
Hip; Osteonecrosis; Femur head necrosis; Arthroplasty; Short stem arthroplasty; PROPHYLACTIC CERCLAGE; FOLLOW-UP; REPLACEMENT; CEMENTLESS; FEMUR; WIRES;
D O I
10.4055/cios21041
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Young age in osteonecrosis of the femoral head (ONFH) demands bone-preserving, short-stem arthroplasty. Several designs including neck-preserving stems and neck-resecting, shortened, standard stems are classified as short stems. There is a paucity of literature investigating risk factors and outcomes of intraoperative complications of neck preserving, short-stem arthroplasty in ONFH. Methods: A total of 107 hips operated with METHA short-stem arthroplasty for ONFH were retrospectively evaluated. The mean age of patients was 43.7 years (range, 27-60 years). Nine patients had an intraoperative fracture. Seven hips received prophylactic cerclage wiring for poor bone quality. Patients were invited for clinical and radiological evaluation at the latest follow-up. Results: The mean follow-up of patients was 47.2 months. Significant association with intraoperative fractures and the need for prophylactic cerclage wiring were found in steroids-, alcohol-, and chronic renal failure-induced ONFH. However, patient sex, body mass index, traumatic/idiopathic ONFH, previous implant in situ, prosthesis size, and single-sitting bilateral total hip replacement (THA) were not the risk factors. All hips showed signs of osteointegration at final follow-up. No revision was done during the study period for any cause. Conclusions: METHA short-stem THA offers excellent functional and radiological outcomes in ONFH. However, precaution must be exercised in patients with steroids-, alcohol-, and renal disorders-induced ONFN due to poor bone quality and higher chances of intraoperative fractures. Also, additional measures such as the use of a high-speed burr and prophylactic cerclage wiring in ONFH may allow predictable and safe use of short stems.
引用
收藏
页码:41 / 47
页数:7
相关论文
共 50 条
  • [31] Early Outcomes of Primary Total Hip Arthroplasty for Osteonecrosis of the Femoral Head in Patients with Human Immunodeficiency Virus in China
    Zhao Chang-Song
    Li Xin
    Zhang Qiang
    Sun Sheng
    Zhao Ru-Gang
    Cai Juan
    中华医学杂志英文版, 2015, 128 (15) : 2059 - 2064
  • [32] Noncemented Total Hip Arthroplasty for Osteonecrosis of the Femoral Head in Elderly Patients
    Wang, Ta-I
    Hung, Shih-Hsin
    Su, Yu-Ping
    Feng, Chi-Quang
    Chiu, Fang-Yao
    Liu, Chien-Lin
    ORTHOPEDICS, 2013, 36 (03) : E271 - E275
  • [33] An Analytical Approach to Study the Intraoperative Fractures of Femoral Shaft During Total Hip Arthroplasty
    Malekmotiei, Leila
    Farahmand, Farzam
    Shodja, Hossein M.
    Samadi-Dooki, Aref
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2013, 135 (04):
  • [34] Outcomes Following Intraoperative Calcar Fractures During Cementless Total Hip Arthroplasty
    Wilson, Eric J.
    Strait, Alexander, V
    Fricka, Kevin B.
    Hamilton, William G.
    Sershon, Robert A.
    JOURNAL OF ARTHROPLASTY, 2024, 39 (09) : S464 - S468
  • [35] Total hip arthroplasty with ultra-short uncemented stem in patients with osteonecrosis of the femoral head: mid-term results
    Necas, Libor
    Hrubina, Maros
    Melisik, Marian
    Cabala, Juraj
    Cibula, Zoltan
    Daniel, Matej
    HIP INTERNATIONAL, 2023, 33 (03) : 463 - 470
  • [36] Risk Factors for Periprosthetic Femoral Fractures After Cementless Total Hip Arthroplasty
    Li, Junwei
    Zhang, Min
    Yao, Jie
    Shao, Long
    Fang, Chaohua
    Cheng, Cheng-Kung
    JOURNAL OF ARTHROPLASTY, 2024, 39 (10) : 2547 - 2554
  • [37] Osteonecrosis of the femoral head treated with cementless total hip arthroplasty - A comparison with other diagnoses
    Chiu, KH
    Shen, WY
    Ko, CK
    Chan, KM
    JOURNAL OF ARTHROPLASTY, 1997, 12 (06) : 683 - 688
  • [38] Rectangular Taper Stem Designs Are Associated With a Higher Risk for Periprosthstic Femoral Fractures After Cementless Total Hip Arthroplasty
    Jeong, Sang-Jin
    Park, Chan-Woo
    Cho, Kyungjun
    Jeong, Jusam
    Lim, Seung-Jae
    Park, Youn-Soo
    JOURNAL OF ARTHROPLASTY, 2023, 38 (11) : 2379 - 2385
  • [39] Revision Hip Arthroplasty in Patients With a Previous Total Hip Replacement for Osteonecrosis of the Femoral Head
    Park, Youn-Soo
    Moon, Young-Wan
    Lee, Keun-Ho
    Lim, Seung-Jae
    ORTHOPEDICS, 2014, 37 (12) : E1058 - E1062
  • [40] Biomechanical reconstruction of the hip: comparison between modular short-stem hip arthroplasty and conventional total hip arthroplasty
    Schmidutz, Florian
    Beirer, Marc
    Weber, Patrick
    Mazoochian, Farhad
    Fottner, Andreas
    Jansson, Volkmar
    INTERNATIONAL ORTHOPAEDICS, 2012, 36 (07) : 1341 - 1347