Collateral damage to the ureter and Nitinol stone baskets during thulium fiber laser lithotripsy

被引:33
作者
Wilson, Christopher R. [1 ]
Hardy, Luke A. [1 ]
Irby, Pierce B. [2 ]
Fried, Nathaniel M. [1 ,2 ,3 ]
机构
[1] Univ N Carolina, Dept Phys & Opt Sci, Charlotte, NC USA
[2] Carolinas Med Ctr, McKay Dept Urol, Charlotte, NC 28203 USA
[3] Johns Hopkins Med Inst, Dept Urol, Baltimore, MD 21205 USA
关键词
ablation; basket; holmium; kidney; laser; lithotripsy; stones; thulium; ureter; YAG LASER; IN-VITRO; TEMPERATURE-DEPENDENCE; PULSE-WIDTH; HOLMIUM; RETROPULSION; ABLATION; ABSORPTION; CALCULI; WATER;
D O I
10.1002/lsm.22348
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
BackgroundThe experimental Thulium fiber laser (TFL) is currently being studied as a potential alternative lithotripter to the clinical gold standard Holmium:YAG laser. Safety studies characterizing undesirable Holmium:YAG laser-induced damage to ureter tissue and stone baskets have been previously reported. Similarly, this study characterizes TFL induced ureter and stone basket damage. MethodsA TFL beam with energy of 35mJ per pulse, pulse duration of 500 mu s, and variable pulse rates of 50-500Hz, was delivered through 100-mu m-core optical fibers, to either porcine ureter wall, in vitro, or a standard 1.9-Fr Nitinol stone basket wire. Ureter perforation times were measured and gross, histological, and optical coherence tomography images of the ablation area were acquired. Stone basket damage was graded as a function of pulse rate, number of pulses, and working distance. ResultsTFL operation at 150, 300, and 500Hz produced mean ureter perforation times of 7.9, 3.8, and 1.8seconds, respectively. Collateral damage widths averaged 510, 370, and 310 mu m. Nitinol wire damage decreased with working distance and was non-existent at distances greater than 1.0mm. In contact mode, 500 pulses delivered at pulse rates 300Hz (1.5seconds) were sufficient to cut Nitinol wires. ConclusionsThe TFL, operated in low pulse energy and high pulse rate mode, may provide a greater safety margin than the standard Holmium:YAG laser for lithotripsy, as evidenced by longer TFL ureter perforation times and shorter non-contact working distances for stone basket damage than previously reported with Holmium:YAG laser. Lasers Surg. Med. 47:403-410, 2015. Lasers Surg. Med. 47:???-???, 2015. (c) 2015 Wiley Periodicals, Inc.
引用
收藏
页码:403 / 410
页数:8
相关论文
共 34 条
  • [1] Adverse Events Resulting from Lasers Used in Urology
    Althunayan, Abdulaziz M.
    Elkoushy, Mohamed A.
    Elhilali, Mostafa M.
    Andonian, Sero
    [J]. JOURNAL OF ENDOUROLOGY, 2014, 28 (02) : 256 - 260
  • [2] ACOUSTIC TRANSIENT GENERATION BY HOLMIUM-LASER-INDUCED CAVITATION BUBBLES
    ASSHAUER, T
    RINK, K
    DELACRETAZ, G
    [J]. JOURNAL OF APPLIED PHYSICS, 1994, 76 (09) : 5007 - 5013
  • [3] Impact of Collateral Damage to Endourologic Tools During Laser Lithotripsy-In Vitro Comparison of Three Different Clinical Laser Systems
    Bader, Markus J.
    Gratzke, Christian
    Hecht, Volkmar
    Schlenker, Boris
    Seitz, Michael
    Reich, Oliver
    Stief, Christian G.
    Sroka, Ronald
    [J]. JOURNAL OF ENDOUROLOGY, 2011, 25 (04) : 667 - 672
  • [4] Thulium fiber laser ablation of kidney stones using a 50-μm-core silica optical fiber
    Blackmon, Richard L.
    Hutchens, Thomas C.
    Hardy, Luke A.
    Wilson, Christopher R.
    Irby, Pierce B.
    Fried, Nathaniel M.
    [J]. OPTICAL ENGINEERING, 2015, 54 (01)
  • [5] Fiber-optic manipulation of urinary stone phantoms using holmium:YAG and thulium fiber lasers
    Blackmon, Richard L.
    Case, Jason R.
    Trammell, Susan R.
    Irby, Pierce B.
    Fried, Nathaniel M.
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (02)
  • [6] Thulium Fiber Laser Lithotripsy Using Tapered Fibers
    Blackmon, Richard L.
    Irby, Pierce B.
    Fried, Nathaniel M.
    [J]. LASERS IN SURGERY AND MEDICINE, 2010, 42 (01) : 45 - 50
  • [7] Analysis of cavitation dynamics during pulsed laser tissue ablation by optical on-line monitoring
    Brinkmann, R
    Hansen, C
    Mohrenstecher, D
    Scheu, M
    Birngruber, R
    [J]. IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 1996, 2 (04) : 826 - 835
  • [8] Chan KF, 1999, LASER SURG MED, V25, P22, DOI 10.1002/(SICI)1096-9101(1999)25:1<22::AID-LSM4>3.0.CO
  • [9] 2-6
  • [10] Damage of Stone Baskets by Endourologic Lithotripters: A Laboratory Study of 5 Lithotripters and 4 Basket Types
    Cordes, Jens
    Nguyen, Felix
    Lange, Birgit
    Brinkmann, Ralf
    Jocham, Dieter
    [J]. ADVANCES IN UROLOGY, 2013, 2013