Reduced susceptibility effects in perfusion fMRI with single-shot spin-echo EPI acquisitions at 1.5 Tesla

被引:62
|
作者
Wang, JJ [1 ]
Li, L
Roc, AC
Alsop, DC
Tang, K
Butler, NS
Schnall, MD
Detre, JA
机构
[1] Univ Penn, Dept Radiol, Metab Magnet Resonance Res & Comp Ctr, Philadelphia, PA 19104 USA
[2] Univ Penn, Dept Neurol, Philadelphia, PA 19104 USA
[3] Harvard Univ, Sch Med, Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02115 USA
关键词
arterial spin label; susceptibility artifacts; spin-echo EPI; perfusion fMRI;
D O I
10.1016/S0730-725X(03)00210-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Arterial spin labeling (ASL) perfusion contrast is not based on susceptibility effects and can therefore be used to study brain function in regions of high static inhornogeneity. As a proof of concept, single-shot spin-echo echo-planar imaging (EPI) acquisition was carried out with a multislice continuous ASL (CASL) method at 1.5T. A bilateral finger tapping paradigm was used in the presence of an exogenously induced susceptibility artifact over left motor cortex. The spin-echo CASL technique was compared with a regular gradient-echo EPI sequence with the same slice thickness, as well as other imaging methods using thin slices and spin-echo acquisitions. The results demonstrate improved functional sensitivity and efficiency of the spin-echo CASL approach as compared with gradient-echo EPI techniques, and a trend of improved sensitivity as compared with spin-echo EPI approach in the brain regions affected by the susceptibility artifact. ASL images, either with or without subtraction of the control, provide a robust alternative to blood oxygenation level dependant (BOLD) methods for activation imaging in regions of high static field inhomogeneity. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 50 条
  • [1] Cardiac MR elastography using reduced-FOV, single-shot, spin-echo EPI
    Sui, Yi
    Arunachalam, Shivaram P.
    Arani, Arvin
    Trzasko, Joshua D.
    Young, Phillip M.
    Glockner, James F.
    Glaser, Kevin J.
    Lake, David S.
    McGee, Kiaran P.
    Manduca, Armando
    Rossman, Phillip J.
    Ehman, Richard L.
    Araoz, Philip A.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (01) : 231 - 238
  • [2] Ultrafast bold fMRI using single-shot spin-echo echo planar imaging
    Boujraf, Said
    Summers, Paul
    Belahsen, Faouzi
    Pruessmann, Klaas
    Kollias, Spyros
    JOURNAL OF MEDICAL PHYSICS, 2009, 34 (01) : 37 - 42
  • [3] Myocardial perfusion with ultra fast spin-echo single-shot echo-planar-imaging
    Pedro Ferreira
    Peter Gatehouse
    David Firmin
    Journal of Cardiovascular Magnetic Resonance, 12 (Suppl 1)
  • [4] Perfusion imaging of the human brain at 1.5 T using a single-shot EPI spin tagging approach
    Clinical Brain Disorders Branch, NIMH, NIH, Bethesda, MD, United States
    不详
    不详
    不详
    不详
    MAGN. RESON. MED., 2 (219-224):
  • [5] Single-shot fast spin-echo diffusion tensor imaging of the lumbar spine at 1.5 and 3 T
    Carballido-Gamio, Julio
    Xu, Duan
    Newitt, David
    Han, Eric T.
    Vigneron, Daniel B.
    Majumdar, Sharmila
    MAGNETIC RESONANCE IMAGING, 2007, 25 (05) : 665 - 670
  • [6] SINGLE-SHOT LOCALIZED ECHO-PLANAR IMAGING (STEAM EPI) AT 4.7 TESLA
    TURNER, R
    VONKIENLIN, M
    MOONEN, CTW
    VANZIJL, PCM
    MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (02) : 401 - 408
  • [7] Perfusion imaging of the human brain at 1.5T using a single-shot EPI spin tagging approach
    Ye, FQ
    Pekar, JJ
    Jezzard, P
    Duyn, T
    Frank, JA
    McLaughlin, AC
    MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (02) : 219 - 224
  • [8] Comparison of single-shot east spin-echo and conventional spin-echo sequences for MR imaging of the heart: Initial experience
    Vignaux, OB
    Augui, J
    Coste, J
    Argaud, C
    Le Roux, P
    Carlier, PG
    Duboc, D
    Legmann, P
    RADIOLOGY, 2001, 219 (02) : 545 - 550
  • [9] Pancreatic cysts: Depiction on single-shot fast spin-echo MR images
    Zhang, XM
    Mitchell, DG
    Dohke, M
    Holland, GA
    Parker, L
    RADIOLOGY, 2002, 223 (02) : 547 - 553
  • [10] Single-shot fast spin-echo MR imaging of the fetus: A pictorial essay
    Huppert, BJ
    Brandt, KR
    Ramin, KD
    King, BF
    RADIOGRAPHICS, 1999, 19 : S215 - S227