Biomarker reproducibility in exhaled breath condensate collected with different condensers

被引:55
|
作者
Rosias, P. P. [1 ]
Robroeks, C. M. [1 ]
Kester, A. [3 ]
den Hartog, G. J.
Wodzig, W. K. [2 ]
Rilkers, G. T. [5 ]
Zimmermann, L. J. [4 ]
van Schayck, C. P.
Joebsis, Q. [1 ]
Dompeling, E. [1 ]
机构
[1] Univ Hosp Maastricht, Caphri Res Inst, Dept Pediat Pulm, NL-6202 AZ Maastricht, Netherlands
[2] Univ Hosp Maastricht, NL-6202 AZ Maastricht, Netherlands
[3] Univ Hosp Maastricht, Caphri Res Inst, Dept Methodol & Stat, NL-6202 AZ Maastricht, Netherlands
[4] Univ Hosp Maastricht, Caphri Res Inst, Dept Gen Practice, NL-6202 AZ Maastricht, Netherlands
[5] Univ Utrecht, Wilhelmina Childrens Hosp, Med Ctr, Dept Immunol, Utrecht, Netherlands
关键词
condenser; cytokines; exhaled breath condensates; hydrogen peroxide; 8-isoprostane; multiplex array;
D O I
10.1183/09031936.00073207
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Optimal collection and analysis of exhaled breath condensate (EBC) are prerequisites for standardisation and reproducibility of assessments. The present study aimed to assess reproducibility of EBC volume, hydrogen peroxide (H2O2), 8-isoprostane and cytokine measurements using different condensers, including a newly developed glass condenser. At four points in time, 30 healthy subjects performed sequential EBC collections randomly using the following four condensers: glass, silicone, EcoScreen (R) (Erich Jaeger GmbH, Hoechberg, Germany) and an optimised glass condenser. In small EBC samples, H2O2 was measured by spectrophotometer, 8-isoprostane by enzyme immunoassay, and cytokines by multiplexed xMAP (R) technology (Luminex Corporation, Austin, TX, USA). The optimised glass condenser yielded significantly more EBC volume (median 2,025 mu L, interquartile range 1,600-2,525). The reproducibility of EBC volume, yielded by the new glass condenser, was comparable with EcoScreer (R) (19-20 coefficients of variation (CV)%), but was significantly better compared with silicone and glass (29-37 CV%). The new condenser was associated with significantly more detections of H2O2, 8-isoprostane, interieukin-2, -4, -5 and -13, and tumour necrosis factor-a. Isoprostane concentrations were significantly higher using the new condenser, whereas H2O2 and cytokine concentrations were not. Reproducibility of biomarkers was equally variable for all condenser types. In conclusion, significantly more exhaled breath condensate volume and biomarker detections were found using the optimised glass condenser, including higher 8-isoprostane levels. However, biomarker reproducibility in exhaled breath condensate in healthy adults was not influenced by the type of condenser.
引用
收藏
页码:934 / 942
页数:9
相关论文
共 50 条
  • [41] Markers of inflammation in exhaled breath condensate of young healthy smokers
    Garey, KW
    Nenhauser, MM
    Robbins, RA
    Danziger, LH
    Rubinstein, I
    CHEST, 2004, 125 (01) : 22 - 26
  • [42] Asymmetric Dimethylarginine in Exhaled Breath Condensate and Serum of Children With Asthma
    Carraro, Silvia
    Giordano, Giuseppe
    Piacentini, Giorgio
    Kantar, Ahmad
    Moser, Serena
    Cesca, Laura
    Berardi, Mariangela
    Di Gangi, Iole M.
    Baraldi, Eugenio
    CHEST, 2013, 144 (02) : 405 - 410
  • [43] Comparison of exhaled breath condensate from nasal and oral collection
    Latzin, P
    Beck, J
    Bartenstein, A
    Griese, M
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2003, 8 (11) : 505 - 510
  • [44] The application of exhaled breath gas and exhaled breath condensate analysis in the investigation of the lower respiratory tract in veterinary medicine: A review
    Cathcart, M. P.
    Love, S.
    Hughes, K. J.
    VETERINARY JOURNAL, 2012, 191 (03) : 282 - 291
  • [45] Exhaled Breath Condensate: A Promising Source for Biomarkers of Lung Disease
    Liang, Yan
    Yeligar, Samantha M.
    Brown, Lou Ann S.
    SCIENTIFIC WORLD JOURNAL, 2012,
  • [46] Eicosanoids in exhaled breath condensate and BAL fluid of patients with sarcoidosis
    Piotrowski, Wojciech J.
    Antczak, Adam
    Marczak, Jerzy
    Nawrocka, Agnieszka
    Kurmanowska, Zofia
    Gorski, Pawel
    CHEST, 2007, 132 (02) : 589 - 596
  • [47] The analysis of volatile organic compounds in exhaled breath and biomarkers in exhaled breath condensate in children - clinical tools or scientific toys?
    van Mastrigt, E.
    de Jongste, J. C.
    Pijnenburg, M. W.
    CLINICAL AND EXPERIMENTAL ALLERGY, 2015, 45 (07) : 1170 - 1188
  • [48] Exhaled breath condensate cytokine level as a diagnostic tool for obstructive sleep apnea syndrome
    Li, Yongxia
    Chongsuvivatwong, Virasakdi
    Geater, Alan
    Liu, Ao
    SLEEP MEDICINE, 2009, 10 (01) : 95 - 103
  • [49] Feasibility of a new method to collect exhaled breath condensate in pre-school children
    Rosias, Philippe P. R.
    Robroeks, Charlotte M.
    van de Kant, Kim D.
    Rijkers, Ger T.
    Zimmermann, Luc J.
    van Schayck, Constant P.
    Heynens, Jan W.
    Jobsis, Quirijn
    Dompeling, Edward
    PEDIATRIC ALLERGY AND IMMUNOLOGY, 2010, 21 (01) : E235 - E244
  • [50] Biomarkers in the exhaled breath condensate of healthy adults: Mapping the path towards reference values
    Koutsokera, Angela
    Loukides, Stelios
    Gourgoulianis, Konstantinos I.
    Kostikas, Konstantinos
    CURRENT MEDICINAL CHEMISTRY, 2008, 15 (06) : 620 - 630