Biomarker reproducibility in exhaled breath condensate collected with different condensers

被引:55
|
作者
Rosias, P. P. [1 ]
Robroeks, C. M. [1 ]
Kester, A. [3 ]
den Hartog, G. J.
Wodzig, W. K. [2 ]
Rilkers, G. T. [5 ]
Zimmermann, L. J. [4 ]
van Schayck, C. P.
Joebsis, Q. [1 ]
Dompeling, E. [1 ]
机构
[1] Univ Hosp Maastricht, Caphri Res Inst, Dept Pediat Pulm, NL-6202 AZ Maastricht, Netherlands
[2] Univ Hosp Maastricht, NL-6202 AZ Maastricht, Netherlands
[3] Univ Hosp Maastricht, Caphri Res Inst, Dept Methodol & Stat, NL-6202 AZ Maastricht, Netherlands
[4] Univ Hosp Maastricht, Caphri Res Inst, Dept Gen Practice, NL-6202 AZ Maastricht, Netherlands
[5] Univ Utrecht, Wilhelmina Childrens Hosp, Med Ctr, Dept Immunol, Utrecht, Netherlands
关键词
condenser; cytokines; exhaled breath condensates; hydrogen peroxide; 8-isoprostane; multiplex array;
D O I
10.1183/09031936.00073207
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Optimal collection and analysis of exhaled breath condensate (EBC) are prerequisites for standardisation and reproducibility of assessments. The present study aimed to assess reproducibility of EBC volume, hydrogen peroxide (H2O2), 8-isoprostane and cytokine measurements using different condensers, including a newly developed glass condenser. At four points in time, 30 healthy subjects performed sequential EBC collections randomly using the following four condensers: glass, silicone, EcoScreen (R) (Erich Jaeger GmbH, Hoechberg, Germany) and an optimised glass condenser. In small EBC samples, H2O2 was measured by spectrophotometer, 8-isoprostane by enzyme immunoassay, and cytokines by multiplexed xMAP (R) technology (Luminex Corporation, Austin, TX, USA). The optimised glass condenser yielded significantly more EBC volume (median 2,025 mu L, interquartile range 1,600-2,525). The reproducibility of EBC volume, yielded by the new glass condenser, was comparable with EcoScreer (R) (19-20 coefficients of variation (CV)%), but was significantly better compared with silicone and glass (29-37 CV%). The new condenser was associated with significantly more detections of H2O2, 8-isoprostane, interieukin-2, -4, -5 and -13, and tumour necrosis factor-a. Isoprostane concentrations were significantly higher using the new condenser, whereas H2O2 and cytokine concentrations were not. Reproducibility of biomarkers was equally variable for all condenser types. In conclusion, significantly more exhaled breath condensate volume and biomarker detections were found using the optimised glass condenser, including higher 8-isoprostane levels. However, biomarker reproducibility in exhaled breath condensate in healthy adults was not influenced by the type of condenser.
引用
收藏
页码:934 / 942
页数:9
相关论文
共 50 条
  • [21] Exhaled breath condensate analysis in horses: A scoping review
    Santi, Thasla de Freitas
    Barbosa, Bianca
    Weber, Saulo Henrique
    Michelotto, Pedro Vicente
    RESEARCH IN VETERINARY SCIENCE, 2024, 168
  • [22] Exhaled breath condensate collection in the mechanically ventilated patient
    Carter, Stewart R.
    Davis, Christopher S.
    Kovacs, Elizabeth J.
    RESPIRATORY MEDICINE, 2012, 106 (05) : 601 - 613
  • [23] A smart mask for exhaled breath condensate harvesting and analysis
    Heng, Wenzheng
    Yin, Shukun
    Min, Jihong
    Wang, Canran
    Han, Hong
    Sani, Ehsan Shirzaei
    Li, Jiahong
    Song, Yu
    Rossiter, Harry B.
    Gao, Wei
    SCIENCE, 2024, 385 (6712) : 954 - 961
  • [24] Induced Sputum, Exhaled NO, and Breath Condensate in Occupational Medicine
    Cherot-Kornobis, Nathalie
    Hulo, Sebastien
    de Broucker, Virginie
    Hassoun, Sidi
    Lepage, Nadege
    Edme, Jean Louis
    Sobaszek, Annie
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 2012, 54 (08) : 922 - 927
  • [25] Correlation between eicosanoids in bronchoalveolar lavage fluid and in exhaled breath condensate
    Antczak, Adam
    Piotrowski, Wojciech
    Marczak, Jerzy
    Ciebiada, Maciej
    Gorski, Pawel
    Barnes, Peter J.
    DISEASE MARKERS, 2011, 30 (05) : 213 - 220
  • [26] Optimising hydrogen peroxide measurement in exhaled breath condensate
    Brooks, Wendy M.
    Lash, Heath
    Kettle, Anthony J.
    Epton, Michael J.
    REDOX REPORT, 2006, 11 (02) : 78 - 84
  • [27] Exhaled breath condensate (EBC) biomarkers in pulmonary fibrosis
    Chow, Sharron
    Thomas, Paul S.
    Malouf, Monique
    Yates, Deborah H.
    JOURNAL OF BREATH RESEARCH, 2012, 6 (01)
  • [28] Hydrogen peroxide in exhaled breath condensate: A clinical study
    Nagaraja, C.
    Shashibhushan, B. L.
    Sagar
    Asif, Mohamed
    Manjunath, P. H.
    LUNG INDIA, 2012, 29 (02) : 123 - 127
  • [29] Cysteinyl leukotrienes in exhaled breath condensate of smoking asthmatics
    Celik, Deniz
    Doruk, Sibel
    Koseoglu, Handan Inonu
    Sahin, Semsettin
    Celikel, Serhat
    Erkorkmaz, Unal
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2013, 51 (05) : 1069 - 1073
  • [30] Collecting exhaled breath condensate (EBC) with two condensers in series: A promising technique for studying the mechanisms of EBC formation, and the volatility of selected biomarkers
    Corradi, Massimo
    Goldoni, Matteo
    Caglieri, Andrea
    Folesani, Giuseppina
    Poli, Diana
    Corti, Marina
    Mutti, Antonio
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2008, 21 (01) : 35 - 44