Determination of glucose concentration in tissue-like material using spatially resolved steady-state diffuse reflectance spectroscopy

被引:2
|
作者
Hjalmarsson, Paer [1 ]
Thennadil, Suresh N. [1 ]
机构
[1] Newcastle Univ, Sch Chem Engn Chem Engn & Adv Mat, Newcastle Upon Tyne NE1 7RU, Tyne & Wear, England
关键词
spatially resolved spectroscopy; optical properties; (NIR) Spectroscopy; non-invasive measurements; glucose sensing; OPTICAL-PROPERTIES; NONINVASIVE DETERMINATION; DIABETIC-PATIENTS; SCATTERING; LIGHT; SKIN;
D O I
10.1117/12.762279
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An important parameter in medical diagnostic and one of the most frequently determined analyte in the hospitals is blood glucose. Fast and accurate methods of measuring blood glucose concentrations could therefore be significant. We will in this paper investigate the feasibility of using a spatially resolved steady-state diffuse reflectance spectroscopy in the wavelength region 1000-1700mn, where glucose has two absorption peaks at around 1250nm and 1600nm, to quickly determine the concentration of glucose in tissue-like material. This method could later be transferred to estimate the amount of glucose in blood both in vivo e.g. the forearm and in vitro e.g. on blood samples. The novel spatially resolved system that is used for this study is based around a 2D InGaAs detector and a fibre probe with 10 fibres, one as a source and 9 to collect the diffuse reflected light at distances between 0.3-2.7mm from the source. An inversion method using Monte Carlo generated diffuse reflectance profiles is used to estimate the absolute absorption coefficient (mu(a)) and reduced scattering coefficient (mu(s)') which could be used to estimate the glucose concentration in the tissue-like phantoms. The method was investigated by performing spatially resolved measurements on turbid gelatin phantoms containing mixtures of water and D2O as absorbers, Intralipid as a scatterer and glucose. The phantoms were made with four different glucose concentrations spanning the range of 0-5000 mg/dl.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] CHARACTERIZATION OF PLASMA-MODIFIED FLUOROPOLYMER SURFACES USING STEADY-STATE AND TIME-RESOLVED FLUORESCENCE SPECTROSCOPY
    LI, M
    PACHOLSKI, ML
    BRIGHT, FV
    APPLIED SPECTROSCOPY, 1994, 48 (05) : 630 - 637
  • [42] A Monte Carlo-based model for steady-state diffuse reflectance spectrometry in human skin: estimation of carbon monoxide concentration in livor mortis
    Bohnert, M
    Walther, R
    Roths, T
    Honerkamp, J
    INTERNATIONAL JOURNAL OF LEGAL MEDICINE, 2005, 119 (06) : 355 - 362
  • [43] A Monte Carlo-based model for steady-state diffuse reflectance spectrometry in human skin: estimation of carbon monoxide concentration in livor mortis
    M. Bohnert
    R. Walther
    T. Roths
    J. Honerkamp
    International Journal of Legal Medicine, 2005, 119 : 355 - 362
  • [44] Quantification of the optical properties of two-layered turbid media by simultaneously analyzing the spectral and spatial information of steady-state diffuse reflectance spectroscopy
    Tseng, Te-Yu
    Chen, Chun-Yu
    Li, Yi-Shan
    Sung, Kung-Bin
    BIOMEDICAL OPTICS EXPRESS, 2011, 2 (04): : 901 - 914
  • [45] Assessment of the optical properties of peaches with fungal infection using spatially-resolved diffuse reflectance technique and their relationships with tissue structural and biochemical properties
    Sun, Ye
    Lu, Renfu
    Pan, Leiqing
    Wang, Xiaochan
    Tu, Kang
    FOOD CHEMISTRY, 2020, 321
  • [46] Non-Invasive, Spatially Resolved Determination of Tissue Properties of the Crystalline Lens with regard to Rheology, Refractive Index, Density and Protein Concentration by using Brillouin Spectroscopy
    Reiss, S.
    Stachs, O.
    Guthoff, R.
    Stolz, H.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2011, 228 (12) : 1079 - 1085
  • [47] Comparative study of optical properties estimation on liquid optical phantoms using spatially-resolved diffuse reflectance spectroscopy and double integrating spheres methods
    Colas, Victor
    Amouroux, Marine
    Daul, Christian
    Perrin-Mozet, Clarice
    Blondel, Walter
    TISSUE OPTICS AND PHOTONICS II, 2022, 12147
  • [48] Quantitative spatially resolved measurement of tissue chromophore concentrations using photoacoustic spectroscopy: application to the measurement of blood oxygenation and haemoglobin concentration
    Laufer, Jan
    Delpy, Dave
    Elwell, Clare
    Beard, Paul
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (01): : 141 - 168
  • [49] Activation mechanism of soluble guanylate cyclase investigated by using steady-state and time-resolved resonance Raman spectroscopy.
    Schelvis, JPM
    Zhao, YD
    Brandish, P
    Kim, SY
    Denninger, J
    Marletta, MA
    Babcock, GT
    BIOPHYSICAL JOURNAL, 2000, 78 (01) : 284A - 284A
  • [50] Monitoring Local Unfolding of Bovine Serum Albumin During Denaturation Using Steady-State and Time-Resolved Fluorescence Spectroscopy
    Denisio M. Togashi
    Alan G. Ryder
    Domhnall O’Shaughnessy
    Journal of Fluorescence, 2010, 20 : 441 - 452