Design of High-sensitivity π-PS-LPFG sensor based on SDOR for simultaneous measurement of SRI and temperature

被引:3
|
作者
Jiang, Huiping [1 ]
Gu, Zhengtian [1 ,2 ]
Zhou, Yuan [1 ]
Wu, Jinyi [1 ]
Li, Zhengyuan [1 ]
Yan, Yuxuan [1 ]
机构
[1] Univ Shanghai Sci & Technol, Coll Sci, Lab Photo Elect Funct Films, 516 Jun Gong Rd, Shanghai 200093, Peoples R China
[2] Univ Shanghai Sci & Technol, Coll Sci, Sch Opt Elect & Comp Engn, POB 249,516 Jun Gong Rd, Shanghai 200093, Peoples R China
来源
OPTIK | 2022年 / 251卷
关键词
Fiber optics; High sensitivity; pi-phase-shifted; Slight deviation of resonance; Multi-parameter measurement; PERIOD FIBER GRATINGS; REFRACTIVE-INDEX; TURNING-POINT; MODE;
D O I
10.1016/j.ijleo.2021.168349
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In this paper, a pi-phase-shifted long-period fiber grating (pi-PS-LPFG) sensor structure operating near phase-match turning point (PMTP) is proposed, which is able to simultaneously detect surrounding refractive index (SRI) and temperature. First, the parameters of film, grating period and grating length are designed by theoretical simulations. Then, a pi-phase-shift is introduced to make the single peak of the 25th cladding mode disappear, and two loss peaks are formed in both sides of the original single peak. When the external environment changes, the distance between the center wavelengths of the two loss peaks changes, while a single peak is formed again at the wavelength of the original 25th cladding mode with the change of intensity. Finally, the wavelength spacing of dual-peak and the intensity of the 25th cladding mode resonance peak with SRI and temperature are analyzed, and the results show a good fitting. The simulation results show that the SRI sensitivities based on wavelength modulation and intensity modulation are 9093.3 nm/RIU and -2870 dB/RIU respectively, and the temperature sensitivities based on wavelength modulation and intensity modulation are -0.3 nm/celcius and 0.217 dB/celcius respectively. Compared with other wavelength and intensity modulation based dual-parameter LPFG sensors, the SRI and temperature sensitivities of our proposed sensor structure are at least 10 times and 2 times higher than that of those LPFG sensors that have been reported. Its low fabrication cost, simple configuration, good fitting and high sensitivity make this sensor have potential applications in multi-parameter measurement.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] High-sensitivity fiber bragg grating temperature sensor at high temperature
    Li, Kuo
    Zhou, Zhenan
    Liu, Aichun
    Wang, Xiuying
    Guangxue Xuebao/Acta Optica Sinica, 2009, 29 (01): : 249 - 251
  • [32] The design of strain sensitising of high-sensitivity SAW sensor based on FBG
    Zhang W.
    International Journal of Information and Communication Technology, 2018, 12 (1-2) : 175 - 185
  • [33] Design of High-Sensitivity Microfluidic Sensor Based on CSRR With Interdigital Structure
    Jiang, Shuren
    Liu, Guohua
    Wang, Mingyang
    Wu, Yuezhi
    Zhou, Jianwei
    IEEE SENSORS JOURNAL, 2023, 23 (16) : 17901 - 17909
  • [34] High Torsion Sensitivity Sensor Based on LPFG With Unique Geometric Structure
    Lu, Chupeng
    Jin, Xiren
    Wang, Shengjia
    Xiang, Zihang
    Sun, Cuiting
    Chen, Xudong
    Ma, Yiwei
    Zhu, Qingzhu
    Tong, Chengguo
    Geng, Tao
    Sun, Weimin
    Yuan, Libo
    IEEE SENSORS JOURNAL, 2021, 21 (05) : 6217 - 6223
  • [35] Fiber Optic Sensor for High-Sensitivity Salinity Measurement
    Rafael Guzman-Sepulveda, Jose
    Ivan Ruiz-Perez, Victor
    Torres-Cisneros, Miguel
    Javier Sanchez-Mondragon, Jose
    Alberto May-Arrioja, Daniel
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2013, 25 (23) : 2323 - 2326
  • [36] Simultaneous measurement of temperature and strain using an integrated LPFG/EFPI fiber-optic sensor
    Jiang, Jian
    Rao, Yunjiang
    Niu, Yongchang
    Wang, Yiping
    Liao, Tiankui
    Guangzi Xuebao/Acta Photonica Sinica, 2003, 32 (09):
  • [37] MMG measurement: A high-sensitivity microphone-based sensor for clinical use
    Courteville, A
    Gharbi, T
    Cornu, JY
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1998, 45 (02) : 145 - 150
  • [38] Development of a high-sensitivity strain measurement system based on a SH SAW sensor
    Oh, Haekwan
    Lee, Keekeun
    Eun, Kyoungtae
    Choa, Sung-Hoon
    Yang, Sang Sik
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2012, 22 (02)
  • [39] Ultracompact Multiaxis Force Sensor Based on Sensitivity Amplification Mechanism for High-Sensitivity and Capacity Measurement
    Lee, Seran
    Jung, Dawoon
    Hwang, Jinhak
    Kim, Uikyum
    IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2025,
  • [40] Cascaded FPI/LPFG interferometer for high-precision simultaneous measurement of strain and temperature
    Chen, Mao-qing
    Zhao, Yong
    Wei, He-ming
    Krishnaswamy, Sridhar
    OPTICAL FIBER TECHNOLOGY, 2019, 53