A comparative study of the reproducibility of landmark identification on posteroanterior and anteroposterior cephalograms generated from cone-beam computed tomography scans

被引:7
作者
Na, Eui-Ri [1 ]
Aljawad, Hussein [2 ]
Lee, Kyung-Min [2 ]
Hwang, Hyeon-Shik [2 ]
机构
[1] Chonnam Natl Univ, Sch Dent, Dept Periodontol, Gwangju, South Korea
[2] Chonnam Natl Univ, Sch Dent, Dept Orthodont, 33 Yongbong Ro, Gwangju 61186, South Korea
基金
新加坡国家研究基金会;
关键词
Posteroanterior cephalogram; Anteroposterior cephalogram; cone-beam computed tomography; ACCURACY; RADIOGRAPHS;
D O I
10.4041/kjod.2019.49.1.41
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: This in-vivo study aimed to compare landmark identification errors in anteroposterior (AP) and posteroanterior (PA) cephalograms generated from cone-beam computed tomography (CBCT) scan data in order to examine the feasibility of using AP cephalograms in clinical settings. Methods: AP and PA cephalograms were generated from CBCT scans obtained from 25 adults. Four experienced and four inexperienced examiners were selected depending on their experience levels in analyzing frontal cephalograms. They identified six cephalometric landmarks on AP and PA cephalograms. The errors incurred in positioning the cephalometric landmarks on the AP and PA cephalograms were calculated by using the straight-line distance and the horizontal and vertical components as parameters. Results: Comparison of the landmark identification errors in CBCT-generated frontal cephalograms revealed that landmark-dependent differences were greater than experience-or projection-dependent differences. Comparisons of landmark identification errors in the horizontal and vertical directions revealed larger errors in identification of the crista galli and anterior nasal spine in the vertical direction and the menton in the horizontal direction, in comparison with the other landmarks. Comparison of landmark identification errors between the AP and PA projections in CBCT-generated images revealed a slightly higher error rate in the AP projections, with no inter-examiner differences. Statistical testing of the differences in landmark identification errors between AP and PA cephalograms showed no statistically significant differences for all landmarks. Conclusions: The reproducibility of CBCT-generated AP cephalograms is comparable to that of PA cephalograms; therefore, AP cephalograms can be generated reliably from CBCT scan data in clinical settings.
引用
收藏
页码:41 / 48
页数:8
相关论文
共 50 条
  • [31] Comparative study of cranial measurements between sexes from Brazil and The Netherlands: A cone-beam computed tomography study
    Gamba, Thiago Oliveira
    Oliveira, Matheus L.
    Flores, Isadora Luana
    Da Silveira, Heraldo Luis Dias
    Sanderink, Gerard C. H.
    Berkhout, W. Erwin R.
    JOURNAL OF ANATOMY, 2023, 243 (02) : 334 - 341
  • [32] Variation in Mesiodistal Root Angulation of Panoramic Images Generated from Cone-beam Computed Tomography
    Liu, Si Qi
    Wen, Fu Jia
    Chen, Hua
    Liu, Yi
    CHINESE JOURNAL OF DENTAL RESEARCH, 2013, 16 (02) : 101 - 110
  • [33] Cone-beam Computed Tomography of the Paranasal Sinuses: Comparison Study with Multidetector Computed Tomography
    Kei, P. L.
    Tan, J. S. P.
    Leong, J. L.
    Kwok, Y. M.
    Lim, W. E. H.
    Chan, L. L.
    HONG KONG JOURNAL OF RADIOLOGY, 2013, 16 (02): : 110 - 116
  • [34] Evaluation of artificial intelligence for detecting periapical pathosis on cone-beam computed tomography scans
    Orhan, K.
    Bayrakdar, I. S.
    Ezhov, M.
    Kravtsov, A.
    Ozyurek, T.
    INTERNATIONAL ENDODONTIC JOURNAL, 2020, 53 (05) : 680 - 689
  • [35] Endodontic Outcome Predictors Identified with Periapical Radiographs and Cone-beam Computed Tomography Scans
    Liang, Yu-Hong
    Li, Gang
    Wesselink, Paul R.
    Wu, Min-Kai
    JOURNAL OF ENDODONTICS, 2011, 37 (03) : 326 - 331
  • [36] The Cameriere method using cone-beam computed tomography (CBCT) scans for dental age estimation in children
    Rozylo-Kalinowska, Ingrid
    Kalinowski, Pawel
    Krasicka, Evelina
    Galic, Ivan
    Mehdi, Fuad
    Cameriere, Roberto
    AUSTRALIAN JOURNAL OF FORENSIC SCIENCES, 2022, 54 (03) : 311 - 325
  • [37] A Comparative Investigation of Cone-beam Computed Tomography and Periapical Radiography in the Diagnosis of a Healthy Periapex
    Pope, Oliver
    Sathorn, Chankhrit
    Parashos, Peter
    JOURNAL OF ENDODONTICS, 2014, 40 (03) : 360 - 365
  • [38] Reliability and reproducibility of linear mandible measurements with the use of a cone-beam computed tomography and two object inclinations
    Tomasi, C.
    Bressan, E.
    Corazza, B.
    Mazzoleni, S.
    Stellini, E.
    Lith, A.
    DENTOMAXILLOFACIAL RADIOLOGY, 2011, 40 (04) : 244 - 250
  • [39] Prevalence of Artifacts in Cone-Beam Computed Tomography: A Retrospective Study
    Mahesh, K. P.
    Deshpande, Prasannasrinivas
    Viveka, S.
    JOURNAL OF INDIAN ACADEMY OF ORAL MEDICINE AND RADIOLOGY, 2022, 34 (04) : 428 - 431
  • [40] Cone-Beam Computed Tomography Study of Mandibular Condylar Morphology
    Yalcin, Eda Didem
    Ararat, Emine
    JOURNAL OF CRANIOFACIAL SURGERY, 2019, 30 (08) : 2621 - 2624