A comparative study of the reproducibility of landmark identification on posteroanterior and anteroposterior cephalograms generated from cone-beam computed tomography scans

被引:7
|
作者
Na, Eui-Ri [1 ]
Aljawad, Hussein [2 ]
Lee, Kyung-Min [2 ]
Hwang, Hyeon-Shik [2 ]
机构
[1] Chonnam Natl Univ, Sch Dent, Dept Periodontol, Gwangju, South Korea
[2] Chonnam Natl Univ, Sch Dent, Dept Orthodont, 33 Yongbong Ro, Gwangju 61186, South Korea
基金
新加坡国家研究基金会;
关键词
Posteroanterior cephalogram; Anteroposterior cephalogram; cone-beam computed tomography; ACCURACY; RADIOGRAPHS;
D O I
10.4041/kjod.2019.49.1.41
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: This in-vivo study aimed to compare landmark identification errors in anteroposterior (AP) and posteroanterior (PA) cephalograms generated from cone-beam computed tomography (CBCT) scan data in order to examine the feasibility of using AP cephalograms in clinical settings. Methods: AP and PA cephalograms were generated from CBCT scans obtained from 25 adults. Four experienced and four inexperienced examiners were selected depending on their experience levels in analyzing frontal cephalograms. They identified six cephalometric landmarks on AP and PA cephalograms. The errors incurred in positioning the cephalometric landmarks on the AP and PA cephalograms were calculated by using the straight-line distance and the horizontal and vertical components as parameters. Results: Comparison of the landmark identification errors in CBCT-generated frontal cephalograms revealed that landmark-dependent differences were greater than experience-or projection-dependent differences. Comparisons of landmark identification errors in the horizontal and vertical directions revealed larger errors in identification of the crista galli and anterior nasal spine in the vertical direction and the menton in the horizontal direction, in comparison with the other landmarks. Comparison of landmark identification errors between the AP and PA projections in CBCT-generated images revealed a slightly higher error rate in the AP projections, with no inter-examiner differences. Statistical testing of the differences in landmark identification errors between AP and PA cephalograms showed no statistically significant differences for all landmarks. Conclusions: The reproducibility of CBCT-generated AP cephalograms is comparable to that of PA cephalograms; therefore, AP cephalograms can be generated reliably from CBCT scan data in clinical settings.
引用
收藏
页码:41 / 48
页数:8
相关论文
共 50 条
  • [1] Landmark identification errors on cone-beam computed tomography-derived cephalograms and conventional digital cephalograms
    Chang, Zwei-Chieng
    Hu, Fu-Chang
    Lai, Eddie
    Yao, Chung-Chen
    Chen, Mu-Hsiung
    Chen, Yi-Jane
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2011, 140 (06) : E289 - E297
  • [2] Accuracy and Landmark Error Calculation Using Cone-Beam Computed Tomography-Generated Cephalograms
    Grauer, Dan
    Cevidanes, Lucia S. H.
    Styner, Martin A.
    Heulfe, Inam
    Harmon, Eric T.
    Zhu, Hongtu
    Proffit, William R.
    ANGLE ORTHODONTIST, 2010, 80 (02) : 286 - 294
  • [3] Use of Reference Ear Plug to improve accuracy of lateral cephalograms generated from cone-beam computed tomography scans
    Hwang, Hyeon-Shik
    Lee, Kyung-Min
    Uhm, Gi-Soo
    Cho, Jin-Hyoung
    McNamara, James A., Jr.
    KOREAN JOURNAL OF ORTHODONTICS, 2013, 43 (02) : 54 - 61
  • [4] Accuracy of integration of dental cast and cephalograms compared with cone-beam computed tomography: a comparative study
    Dai, Fanfan
    Chen, Si
    Feng, Tingting
    Lu, Wenhsuan
    Chen, Gui
    Jiang, Jiuhui
    Jiang, Ruoping
    Lin, Jiuxiang
    Han, Bing
    Xu, Tianmin
    ODONTOLOGY, 2023, 111 (01) : 238 - 247
  • [5] Automated landmark identification on cone-beam computed tomography: Accuracy and reliability
    Ghowsi, Ali
    Hatcher, David
    Suh, Heeyeon
    Wile, David
    Castro, Wesley
    Krueger, Jan
    Park, Joorok
    Oh, Heesoo
    ANGLE ORTHODONTIST, 2022, 92 (05) : 642 - 654
  • [6] Effect of Experience in Landmark Identification on 2D Lateral Cephalograms on Performance of Dental Students Concerning Landmark Identification on 3D Cone Beam Computed Tomography Scans
    Golshah, Amin
    Khavid, Atefeh
    Nikkerdar, Nafiseh
    Godiny, Mostafa
    Imani, Mohammad Moslem
    Mozafari, Neda
    PESQUISA BRASILEIRA EM ODONTOPEDIATRIA E CLINICA INTEGRADA, 2020, 20 : 1 - 10
  • [7] The reliability of cone-beam computed tomography (CBCT) - Generated frontal cephalogramsq
    Kim, So-Jin
    Park, Soo-Byung
    Kim, Yong-Il
    Cho, Bong-Hae
    Hwang, Dae-Seok
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2012, 40 (08) : E331 - E336
  • [8] Comparative study of jaws with multislice computed tomography and cone-beam computed tomography
    Carrafiello, G.
    Dizonno, M.
    Colli, V.
    Strocchi, S.
    Taubert, S. Pozzi
    Leonardi, A.
    Giorgianni, A.
    Barresi, M.
    Macchi, A.
    Bracchi, E.
    Conte, L.
    Fugazzola, C.
    RADIOLOGIA MEDICA, 2010, 115 (04): : 600 - 611
  • [9] Are three-dimensional airway evaluations obtained through computed and cone-beam computed tomography scans predictable from lateral cephalograms? A systematic review of evidence
    Eslami, Ehsan
    Katz, Eliot S.
    Baghdady, Mariam
    Abramovitch, Kenneth
    Masoud, Mohamed I.
    ANGLE ORTHODONTIST, 2017, 87 (01) : 159 - 167
  • [10] Comparison of transverse analysis between posteroanterior cephalogram and cone-beam computed tomography
    Lee, Kyung-Min
    Hwang, Hyeon-Shik
    Cho, Jin-Hyoung
    ANGLE ORTHODONTIST, 2014, 84 (04) : 715 - 719