The volume effect of the stomach on intestinal activity on same-day exercise-rest Tc-99m tetrofosmin myocardial imaging

被引:28
作者
Boz, A [1 ]
Yildiz, A [1 ]
Güngör, F [1 ]
Karayalçin, B [1 ]
Erkiliç, M [1 ]
机构
[1] Akdeniz Univ, Fac Med, Dept Nucl Med, Antalya, Turkey
关键词
artifacts; inferior wail; meal; myocardium; SPECT; tetrofosmin;
D O I
10.1097/00003072-200107000-00010
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of this study was to investigate quantitatively the volume effect of the stomach on the prevention of intestinal artifacts in the rest phase on same-day exercise-rest Tc-99m tetrofosmin myocardial perfusion scintigraphy. Materials and Methods: The study was performed in 81 consecutive patients (43 men, 38 women; mean age, 57 +/- 9 years) who were referred for routine Tc-99m tetrofosmin exercise-rest SPECT myocardial perfusion imaging with normal scintigrams or completely normal inferior wall perfusion on visual assessment of SPECT images. Group A (control group, n = 41) and group B in = 40) were given 200 mi milk to enhance the hepatobiliary clearance of tetrofosmin 30 minutes before the exercise SPECT acquisition study and just after the injection for the rest SPECT acquisition study. For the rest SPECT acquisition study, patients in group B were given, in addition to milk, a standard solid and fluid meal to enhance the volume of the stomach after the injection of Tc-99m tetrofosmin. In all patients, both exercise and rest SPECT acquisitions were started 45 minutes after the injection of Tc-99m tetrofosmin, Myocardial and abdominal activity were assessed on three separate views in the rest phase of the study, and the mean myocardium-to-abdomen count ratios were calculated, In addition, the presence of interfering intestinal activity was assessed visually on SPECT images, Infracardiac activity was described as absent when it was equal to lung background, Results: The myocardial-to-abdominal ratios were 1.38 +/- 0.05 and 1.95 +/- 0.04 in groups A and B, respectively (P < 0.0001). interfering intestinal activity with varying degrees of intensity was seen in 20 patients in group A (49%) and in 5 patients in group B (13%; P < 0.001), Conclusions: These results suggest that filling of the stomach with some fluid and solid food before rest acquisition on the same-day stress-rest protocol, because of its volume effect, may provide a high target-to-non-target ratio for myocardial imaging and thus may reduce the frequency of intestinal artifacts.
引用
收藏
页码:622 / 625
页数:4
相关论文
共 9 条
  • [1] Boz A, 1996, J NUCL MED, V37, P1916
  • [2] BRAAT SH, 1994, J NUCL MED, V35, P1581
  • [3] PROBLEMS OF DUODENOGASTRIC REFLUX IN TC-99M HEXA MIBI PLANAR, TOMOGRAPHIC AND BULLS EYE DISPLAY
    HASSAN, IM
    MOHAMMAD, MMJ
    CONSTANTINIDES, C
    NAIR, M
    BELANI, N
    ABDELDAYEM, HM
    [J]. CLINICAL NUCLEAR MEDICINE, 1989, 14 (04) : 286 - 289
  • [4] INVESTIGATION OF MEASURES TO REDUCE INTERFERING ABDOMINAL ACTIVITY ON REST MYOCARDIAL IMAGES WITH TC-99M SESTAMIBI
    HURWITZ, GA
    CLARK, EM
    SLOMKA, PJ
    SIDDIQ, SK
    [J]. CLINICAL NUCLEAR MEDICINE, 1993, 18 (09) : 735 - 741
  • [5] Kabasakal L, 1996, J NUCL MED, V37, P1285
  • [6] Early duodenogastric reflux in Tc-99m tetrofosmin myocardial scintigraphy:: A case report
    Karayalcin, B
    Boz, A
    Güngör, F
    [J]. CLINICAL NUCLEAR MEDICINE, 1998, 23 (12) : 844 - 845
  • [7] Frequency of extra-cardiac activity and its effect on Tc-99(m)-MIBI cardiac SPET interpretation
    Rehm, PK
    Atkins, FB
    Ziessman, HA
    Green, SE
    Akin, EA
    Fox, LM
    Hixson, DJ
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 1996, 17 (10) : 851 - 856
  • [8] Wackers Frans J. T., 1996, P443
  • [9] Metoclopramide has no effect on abdominal activity of sestamibi in myocardial SPET
    Weinmann, P
    Moretti, JL
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 1999, 20 (07) : 623 - 625