Corneal Topographic Astigmatism Based on Total Corneal Power Data (CorT Total): A Benchmark for Total Corneal Astigmatism

被引:5
作者
Alpins, Noel [1 ,2 ]
Ong, James K. Y. [3 ]
Randleman, J. Bradley [4 ]
Nevyas-Wallace, Anita [5 ]
Stamatelatos, George [1 ]
机构
[1] NewVis Clin, Melbourne, Vic, Australia
[2] Univ Melbourne, Dept Ophthalmol, Melbourne, Vic, Australia
[3] ASSORT Pty Ltd, Melbourne, Vic, Australia
[4] Cleveland Clin Fdn, Cole Eye Inst, 9500 Euclid Ave, Cleveland, OH 44195 USA
[5] Nevyas Eye Associates, Delaware Valley Laser Surg Inst, Philadelphia, PA USA
关键词
corneal topographic astigmatism (CorT); corneal tomography; total corneal power; IN-SITU KERATOMILEUSIS; LIGHT-REFLEX; REFRACTIVE ASTIGMATISM; ORBSCAN-II; SURGERY; CENTRATION; AGREEMENT; ABLATION; OUTCOMES; VERTEX;
D O I
10.1097/ICO.0000000000002162
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate how closely manufacturer-provided measures of total corneal astigmatism correspond with the manifest refractive cylinder, as compared to a benchmark of corneal topographic astigmatism calculated on the basis of measured total corneal power (TCP) data (CorT Total). Methods: The SD of the ocular residual astigmatism magnitude (ORAsd) was evaluated for normal virgin eyes based on an optimized benchmark CorT Total and the various measures of total corneal astigmatism provided by 3 different Scheimpflug tomographers. Results: The CorT Total corresponded with the manifest refractive cylinder at least as well as all the measures of total corneal astigmatism provided by the tomographers [Sirius CorT Total ORAsd: 0.320D (standard error [SE] 0.017D), Sirius TCP 4 mm ORAsd: 0.324D (SE 0.017D); Pentacam CorT Total ORAsd: 0.338D (SE 0.027D), Pentacam total corneal refractive power apex zone 4 mm ORAsd: 0.337D (SE 0.029D); Galilei CorT Total ORAsd: 0.472D (SE 0.068D), and Galilei TCP2 ORAsd: 0.536D (SE 0.124D)]. The difference between CorT Total and best measure on each tomographer was not statistically significant (Sirius TCP 4 mm: P = 0.24, Pentacam total corneal refractive power apex zone 4 mm: P = 0.64, Galilei TCP2: P = 0.24). Most of the manufacturer-provided measures did not correspond closely with the manifest refractive cylinder. When there were multiple measures of total corneal astigmatism, those derived from a zone with a diameter of 4.0 mm corresponded best with the manifest refractive cylinder. Conclusions: The CorT Total is a reliable benchmark measure that can be used to assess how well other measures of total corneal astigmatism correspond with the manifest refractive cylinder.
引用
收藏
页码:431 / 436
页数:6
相关论文
共 50 条
  • [31] New method of quantifying corneal topographic astigmatism that corresponds with manifest refractive cylinder
    Alpins, Noel
    Ong, James K. Y.
    Stamatelatos, George
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (11) : 1978 - 1988
  • [32] The Impact of Posterior Corneal Astigmatism on Surgically Induced Astigmatism in Cataract Surgery
    Liu, Wenjie
    Yang, Lichun
    Liu, Jiewei
    INTERNATIONAL JOURNAL OF GENERAL MEDICINE, 2022, 15 : 8417 - 8425
  • [33] Correcting astigmatism with toric intraocular lenses: Effect of posterior corneal astigmatism
    Koch, Douglas D.
    Jenkins, Richard B.
    Weikert, Mitchell P.
    Yeu, Elizabeth
    Wang, Li
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (12) : 1803 - 1809
  • [34] Corneal Astigmatism Stability in Descemet Membrane Endothelial Keratoplasty for Fuchs Corneal Dystrophy
    Yokogawa, Hideaki
    Sanchez, P. James
    Mayko, Zachary M.
    Straiko, Michael D.
    Terry, Mark A.
    CORNEA, 2016, 35 (07) : 932 - 937
  • [35] Relation of Corneal Astigmatism with Various Corneal Image Quality Parameters in a Large Cohort of Naive Corneas
    Yousif, Mohamed Omar
    Elkitkat, Rania Serag
    Alaarag, Noha Abdelsadek
    Shams, Abdelrhman
    Gharieb, Hesham Mohamed
    CLINICAL OPHTHALMOLOGY, 2020, 14 : 2203 - 2210
  • [36] Scleral Shape and Its Correlations With Corneal Astigmatism
    Consejo, Alejandra
    Rozema, Jos J.
    CORNEA, 2018, 37 (08) : 1047 - 1052
  • [37] The influence of corneal wound size on surgically induced corneal astigmatism after phacoemulsification
    Wei, Yi-Hsuan
    Chen, Wei-Li
    Su, Pei-Yuang
    Shen, Elizabeth P.
    Hu, Fung-Rong
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2012, 111 (05) : 284 - 289
  • [38] Correction of low corneal astigmatism in cataract surgery
    Leon, Pia
    Pastore, Marco Rocco
    Zanei, Andrea
    Umari, Ingrid
    Messai, Meriem
    Negro, Corrado
    Tognetto, Daniele
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2015, 8 (04) : 719 - 724
  • [39] Analysing the correlation between differential corneal thickness along principal meridians and corneal astigmatism: implications for whole-eye astigmatism
    Zhao, Dian
    Mei, Bo
    Zhu, Liting
    Wen, Long
    Zhou, Chunyang
    EYE, 2025, : 1465 - 1469
  • [40] Vecto-keratometry: determination of anterior corneal astigmatism in manual keratometers using power vectors
    Salvador-Roger, Raquel
    Vila-Andres, Rosa
    Mico, Vicente
    Esteve-Taboada, Jose J.
    EXPERT REVIEW OF MEDICAL DEVICES, 2023, 20 (06) : 517 - 524