Corneal Topographic Astigmatism Based on Total Corneal Power Data (CorT Total): A Benchmark for Total Corneal Astigmatism

被引:6
作者
Alpins, Noel [1 ,2 ]
Ong, James K. Y. [3 ]
Randleman, J. Bradley [4 ]
Nevyas-Wallace, Anita [5 ]
Stamatelatos, George [1 ]
机构
[1] NewVis Clin, Melbourne, Vic, Australia
[2] Univ Melbourne, Dept Ophthalmol, Melbourne, Vic, Australia
[3] ASSORT Pty Ltd, Melbourne, Vic, Australia
[4] Cleveland Clin Fdn, Cole Eye Inst, 9500 Euclid Ave, Cleveland, OH 44195 USA
[5] Nevyas Eye Associates, Delaware Valley Laser Surg Inst, Philadelphia, PA USA
关键词
corneal topographic astigmatism (CorT); corneal tomography; total corneal power; IN-SITU KERATOMILEUSIS; LIGHT-REFLEX; REFRACTIVE ASTIGMATISM; ORBSCAN-II; SURGERY; CENTRATION; AGREEMENT; ABLATION; OUTCOMES; VERTEX;
D O I
10.1097/ICO.0000000000002162
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate how closely manufacturer-provided measures of total corneal astigmatism correspond with the manifest refractive cylinder, as compared to a benchmark of corneal topographic astigmatism calculated on the basis of measured total corneal power (TCP) data (CorT Total). Methods: The SD of the ocular residual astigmatism magnitude (ORAsd) was evaluated for normal virgin eyes based on an optimized benchmark CorT Total and the various measures of total corneal astigmatism provided by 3 different Scheimpflug tomographers. Results: The CorT Total corresponded with the manifest refractive cylinder at least as well as all the measures of total corneal astigmatism provided by the tomographers [Sirius CorT Total ORAsd: 0.320D (standard error [SE] 0.017D), Sirius TCP 4 mm ORAsd: 0.324D (SE 0.017D); Pentacam CorT Total ORAsd: 0.338D (SE 0.027D), Pentacam total corneal refractive power apex zone 4 mm ORAsd: 0.337D (SE 0.029D); Galilei CorT Total ORAsd: 0.472D (SE 0.068D), and Galilei TCP2 ORAsd: 0.536D (SE 0.124D)]. The difference between CorT Total and best measure on each tomographer was not statistically significant (Sirius TCP 4 mm: P = 0.24, Pentacam total corneal refractive power apex zone 4 mm: P = 0.64, Galilei TCP2: P = 0.24). Most of the manufacturer-provided measures did not correspond closely with the manifest refractive cylinder. When there were multiple measures of total corneal astigmatism, those derived from a zone with a diameter of 4.0 mm corresponded best with the manifest refractive cylinder. Conclusions: The CorT Total is a reliable benchmark measure that can be used to assess how well other measures of total corneal astigmatism correspond with the manifest refractive cylinder.
引用
收藏
页码:431 / 436
页数:6
相关论文
共 28 条
[1]   New method of targeting vectors to treat astigmatism [J].
Alpins, NA .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1997, 23 (01) :65-75
[2]   Corneal Topographic Astigmatism (CorT) to Quantify Total Corneal Astigmatism [J].
Alpins, Noel ;
Ong, James K. Y. ;
Stamatelatos, George .
JOURNAL OF REFRACTIVE SURGERY, 2015, 31 (03) :182-U110
[3]   New method of quantifying corneal topographic astigmatism that corresponds with manifest refractive cylinder [J].
Alpins, Noel ;
Ong, James K. Y. ;
Stamatelatos, George .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (11) :1978-1988
[4]  
[Anonymous], 1997, Bootstrap methods and their applications
[5]   Clinical Outcomes of Corneal Vertex Versus Central Pupil References with Aberration-Free Ablation Strategies and LASIK [J].
Arbelaez, Maria Clara ;
Vidal, Camila ;
Arba-Mosquera, Samuel .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (12) :5287-5294
[6]   ORTHOGONAL AND NONORTHOGONAL METHODS FOR PARTITIONING REGRESSION VARIANCE [J].
CREAGER, JA .
AMERICAN EDUCATIONAL RESEARCH JOURNAL, 1971, 8 (04) :671-676
[7]   Refractive cylinder outcomes after calculating toric intraocular lens cylinder power using total corneal refractive power [J].
Davison, James A. ;
Potvin, Richard .
CLINICAL OPHTHALMOLOGY, 2015, 9 :1511-1517
[8]   Corneal changes after laser refractive surgery for myopia: Comparison of Orbscan II and Pentacam findings [J].
Hashemi, Hassan ;
Mehravaran, Shiva .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (05) :841-847
[9]   Repeatability, reproducibility, and agreement characteristics of rotating Scheimpflug photography and scanning-slit corneal topography for corneal power measurement [J].
Kawamorita, Takushi ;
Uozato, Hiroshi ;
Kamiya, Kazutaka ;
Bax, Leon ;
Tsutsui, Kenta ;
Aizawa, Daisuke ;
Shimizu, Kimiya .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (01) :127-133
[10]  
Kermani Omid, 2009, J Refract Surg, V25, pS98, DOI 10.3928/1081597X-20090115-04