iron coagulant;
chemical coagulation;
electrocoagulation;
microfiltration;
fouling;
water treatment;
D O I:
10.1016/j.memsci.2007.10.009
中图分类号:
TQ [化学工业];
学科分类号:
0817 ;
摘要:
A bench-scale study was undertaken to evaluate iron chemical coagulation and electrocoagulation pretreatment for dead-end, constant pressure microfiltration of surface water. Fouling of a commercially available PVDF membrane with conventional chemical coagulation pretreatment was found to (1) be insensitive to pH in the range 6.4-8.3, (2) decrease only when >= 10 mg/L Fe3+ were dosed and (3) exacerbate with increasing transmembrane pressure. These results were consistent with creation of larger flocs at high iron dosages that decreased cake specific resistance and formation of compressible cakes that increased hydraulic resistance at higher pressures. A substantial intermediate blocking stage was observed prior to cake formation during raw water microfiltration whereas for coagulated waters, cake filtration was the predominant flux decline mechanism for almost the entire duration of microfiltration. Fouling was not alleviated significantly by iron electrocoagulation in the entire range of experimental conditions investigated since soluble ferrous iron was unexpectedly generated at the anode. Hence, conventional iron chemical coagulation is recommended over iron electrocoagulation for pretreatment of surface waters prior to low-pressure membrane filtration. Chemical and electrocoagulation pretreatment decreased ultraviolet absorbance to a greater extent than dissolved organic carbon. Hence, disinfection by-product control by coagulation-microfiltration is achieved by decreasing the concentration of natural organic matter precursors as well as their reactivity towards chlorine. (C) 2007 Elsevier B.V. All rights reserved.
机构:
School of Civil and Transportation, Hebei University of Technology, Tianjin
Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, BeijingSchool of Civil and Transportation, Hebei University of Technology, Tianjin
Zhao K.
Yang C.-F.
论文数: 0引用数: 0
h-index: 0
机构:
School of Civil and Transportation, Hebei University of Technology, TianjinSchool of Civil and Transportation, Hebei University of Technology, Tianjin
Yang C.-F.
Sun J.-Q.
论文数: 0引用数: 0
h-index: 0
机构:
Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing
University of Chinese Academy of Sciences, BeijingSchool of Civil and Transportation, Hebei University of Technology, Tianjin
Sun J.-Q.
Li J.
论文数: 0引用数: 0
h-index: 0
机构:
School of Civil and Transportation, Hebei University of Technology, TianjinSchool of Civil and Transportation, Hebei University of Technology, Tianjin
Li J.
Hu C.-Z.
论文数: 0引用数: 0
h-index: 0
机构: