Rapid detection of Salmonella typhimurium on fresh spinach leaves using phage-immobilized magnetoelastic biosensors

被引:2
|
作者
Horikawa, Shin [1 ]
Li, Suiqiong [1 ]
Chai, Yating [1 ]
Park, Mi-Kyun [1 ]
Shen, When [1 ]
Barbaree, James M. [2 ]
Vodyanoy, Vitaly J. [3 ]
Chin, Bryan A. [1 ]
机构
[1] Auburn Univ, Dept Mech Engn, Auburn, AL 36849 USA
[2] Auburn Univ, Dept Sci Biol, Auburn, AL 36849 USA
[3] Auburn Univ, Dept Anat Physiol & Pharmacol, Auburn, AL 36849 USA
来源
SENSING FOR AGRICULTURE AND FOOD QUALITY AND SAFETY III | 2011年 / 8027卷
关键词
Salmonella typhimurium; spinach; rapid detection; biosensor; sensor; phage; magnetoelastic;
D O I
10.1117/12.883707
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
This paper presents an investigation into the use of magnetoelastic biosensors for the rapid detection of Salmonella typhimurium on fresh spinach leaves. The biosensors used in this investigation were comprised of a strip-shaped, gold-coated sensor platform (2 mm-long) diced from a ferromagnetic, amorphous alloy and a filamentous fd-tet phage which specifically binds with S. typhimurium. After surface blocking with bovine serum albumin, these biosensors were, without any preceding sample preparation, directly placed on wet spinach leaves inoculated with various concentrations of S. typhimurium. Upon contact with cells, the phage binds S. typhimurium to the sensor thereby increasing the total mass of the sensor. This change in mass causes a corresponding decrease in the sensor's resonant frequency. After 25 min, the sensors were collected from the leaf surface and measurements of the resonant frequency were performed immediately. The total assay time was less than 30 min. The frequency changes for measurement sensors (i.e., phage-immobilized) were found to be statistically different from those for control sensors (sensors without phage), down to 5 x 10(6) cells/ml. The detection limit may be improved by using smaller, micron-sized sensors that will have a higher probability of contacting Salmonella on the rough surfaces of spinach leaves.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] The effect of incubation time for Salmonella Typhimurium binding to phage-based magnetoelastic biosensors
    Park, Mi-Kyung
    Wikle, Howard C., III
    Chai, Yating
    Horikawa, Shin
    Shen, Wen
    Chin, Bryan A.
    FOOD CONTROL, 2012, 26 (02) : 539 - 545
  • [22] The effect of incubation temperature on the binding of Salmonella typhimurium to phage-based magnetoelastic biosensors
    Park, Mi-Kyung
    Oh, Jun-Hyun
    Chin, Bryan A.
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 160 (01): : 1427 - 1433
  • [23] Rapid and Sensitive Detection of Salmonella Typhimurium on Eggshells by Using Wireless Biosensors
    Chai, Yating
    Li, Suiqiong
    Horikawa, Shin
    Park, Mi-Kyung
    Vodyanoy, Vitaly
    Chin, Bryan A.
    JOURNAL OF FOOD PROTECTION, 2012, 75 (04) : 631 - 636
  • [24] A magnetoelastic resonance biosensor immobilized with polyclonal antibody for the detection of Salmonella typhimurium
    Guntupalli, R.
    Hu, J.
    Lakshmanan, Ramji S.
    Huang, T. S.
    Barbaree, James M.
    Chin, Bryan A.
    BIOSENSORS & BIOELECTRONICS, 2007, 22 (07): : 1474 - 1479
  • [25] Lytic Phage-Based Magnetoelastic Biosensors for On-site Detection of Methicillin-Resistant Staphylococcus aureus on Spinach Leaves
    Byeon, Haeng Mi
    Vodyanoy, Vitaly J.
    Oh, Jun-Hyun
    Kwon, Joong-Ho
    Park, Mi-Kyung
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2015, 162 (08) : B230 - B235
  • [26] Bacterial assessment of phage magnetoelastic sensors for Salmonella enterica Typhimurium detection in chicken meat
    Chen, I-Hsuan
    Horikawa, Shin
    Bryant, Kayla
    Riggs, Rebecca
    Chin, Bryan A.
    Barbaree, James M.
    FOOD CONTROL, 2017, 71 : 273 - 278
  • [27] Detection of Bacillus anthracis Spores Using Phage-Immobilized Magnetostrictive Milli/Micro Cantilevers
    Fu, Liling
    Li, Suiqiong
    Zhang, Kewei
    Chen, I-Hsuan
    Barbaree, James M.
    Zhang, Anxue
    Cheng, Zhongyang
    IEEE SENSORS JOURNAL, 2011, 11 (08) : 1684 - 1691
  • [28] Rapid and Sensitive Detection of Salmonella Typhimurium on Plastic Food Processing Plates by Using Wireless Biosensors
    Liu, Yuzhe
    Horikawa, Shin
    Du, Songtao
    Chai, Yating
    Hu, Jiajia
    Wang, Fengen
    Chin, Bryan A.
    SENSORS FOR AGRICULTURE, 2015, 69 (38): : 33 - 40
  • [29] The detection of Salmonella typhimurium on shell eggs using phagebased biosensors
    Chai, Yating
    Li, Suiqiong
    Horikawa, Shin
    Shen, Wen
    Park, Mi-kyung
    Vodyanoy, Vitaly J.
    Chin, Bryan A.
    SENSING FOR AGRICULTURE AND FOOD QUALITY AND SAFETY III, 2011, 8027
  • [30] Detection of of Salmonella typhimurium using phage based magnetostrictive sensor
    Lakshmanan, Ramji S.
    Hu, Jing
    Guntupalli, Rajesh
    Wan, Jiehui
    Huang, Shichu
    Yang, Hong
    Petrenko, Valery A.
    Barbaree, James M.
    Chin, Bryan A.
    CHEMICAL AND BIOLOGICAL SENSING VII, 2006, 6218