High-speed liquid chromatography/tandem mass spectrometry using a monolithic column for high-throughput bioanalysis

被引:75
作者
Wu, JT [1 ]
Zeng, H [1 ]
Deng, YZ [1 ]
Unger, SE [1 ]
机构
[1] Dupont Merck Pharmaceut Co, Stine Haskell Res Ctr, Newark, DE 19714 USA
关键词
D O I
10.1002/rcm.348
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
With the ever-increasing workload from a variety of in vitro and in vivo screening procedures, new analytical methodologies to perform bioanalysis in an accurate and high-throughput manner are in great demand. In this work, monolithic columns were used instead of conventional particulate HPLC columns to perform chromatographic separations. Because the pressure drop on a monolithic column was considerably lower than that on a particulate column, a high flow rate (6 mL/min) was used for a 4.6 x 50 mm monolithic column with a total backpressure of about 61 bar measured using acetonitrile/water (50:50). The capability of using a regular column length at high flow rates, combined with the extremely small dependency of separation efficiency on linear flow velocity, allowed for the generation of sufficient chromatographic resolving power in a significantly reduced runtime. As demonstrated in this work, a plasma extract of a mixture of tempazepam, tamoxifen, fenfluramine, and alprozolam were baseline separated within a total analysis time of one minute. An average peak width at half maximum of approximately one second was noted using a generic broad gradient. It was also found that the separation efficiency and signal/noise (S/N) ratios for this separation remained almost constant at flow rates of 1,3, and 6 mL/min, respectively. The ruggedness of the separation was evaluated by injecting 600 plasma extracts containing the replicates of a standard curve of the above mixture during an overnight run. The chromatographic retention time, separation quality, peak response and sensitivity were highly reproducible throughout the run. This high-speed liquid chromatography/tandem mass spectrometry (LC/MS/MS) system has been used routinely in the authors' laboratory to support drug discovery programs. Copyright (C) 2001 John Wiley & Sons, Ltd.
引用
收藏
页码:1113 / 1119
页数:7
相关论文
共 50 条
  • [1] Ternary-column system for high-throughput direct-injection bioanalysis by liquid chromatography/tandem mass spectrometry
    Xia, YQ
    Whigan, DB
    Powell, ML
    Jemal, M
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2000, 14 (02) : 105 - 111
  • [2] High-throughput chiral liquid chromatography/tandem mass spectrometry
    Bakhtiar, R
    Tse, FLS
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2000, 14 (13) : 1128 - 1135
  • [3] High-throughput liquid chromatography-tandem mass spectrometry determination of bupropion and its metabolites in human, mouse and rat plasma using a monolithic column
    Borges, V
    Yang, E
    Dunn, J
    Henion, J
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 804 (02): : 277 - 287
  • [4] High-throughput biological sample analysis using on-line turbulent flow extraction combined with monolithic column liquid chromatography/tandem mass spectrometry
    Zhou, SL
    Zhou, HY
    Larson, M
    Miller, DL
    Mao, DM
    Jiang, XY
    Weng, ND
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (15) : 2144 - 2150
  • [5] High-throughput analysis of insecticides on malaria vectors using liquid chromatography tandem mass spectrometry
    Spielmeyer, Astrid
    Schetelig, Marc F.
    Etang, Josiane
    PLOS ONE, 2019, 14 (02):
  • [6] A high-throughput monoamine oxidase inhibition assay using liquid chromatography with tandem mass spectrometry
    Yan, ZY
    Caldwell, GW
    Zhao, BY
    Reitz, AB
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (08) : 834 - 840
  • [7] Increased productivity in quantitative bioanalysis using a monolithic column coupled with high-flow direct-injection liquid chromatography/tandem mass spectrometry
    Huang, Mike-Qingtao
    Mao, Yan
    Jemal, Mohammed
    Arnold, Mark
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (11) : 1709 - 1714
  • [8] High throughput analysis of proteome by multidimensional liquid chromatography with monolithic column and MALDI mass spectrometry
    Cho, Kun
    Kim, Jin Young
    Lee, Jeong Hwa
    Park, Gun Wook
    Yoo, Jong Shin
    MOLECULAR & CELLULAR PROTEOMICS, 2004, 3 (10) : S280 - S280
  • [9] High-throughput plasma docetaxel quantification by liquid chromatography-tandem mass spectrometry
    Corona, Giuseppe
    Elia, Caterina
    Casetta, Bruno
    Frustaci, Sergio
    Toffoli, Giuseppe
    CLINICA CHIMICA ACTA, 2011, 412 (3-4) : 358 - 364
  • [10] High-throughput cytochrome P450 inhibition assays by ultrafast gradient liquid chromatography with tandem mass spectrometry using monolithic columns
    Peng, SX
    Barbone, AG
    Ritchie, DM
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (06) : 509 - 518