Mandibular Bone Structure Analysis Using Cone Beam Computed Tomography vs Primary Implant Stability: An Ex Vivo Study

被引:13
作者
Pauwels, Ruben [1 ,2 ]
Sessirisombat, Somchai [3 ]
Panmekiate, Soontra [1 ]
机构
[1] Chulalongkorn Univ, Dept Radiol, Fac Dent, 34 Henri Dunant Rd, Bangkok 10330, Thailand
[2] Katholieke Univ Leuven, Biomed Sci Grp, Dept Imaging & Pathol, OMFS IMPATH Res Grp, Leuven, Belgium
[3] Chulalongkorn Univ, Dept Oral & Maxillofacial Surg, Fac Dent, Bangkok, Thailand
关键词
bone quality; computer-assisted image processing; cone beam computed tomography; dental implant; implant stability quotient; insertion torque; DENTAL IMPLANTS; IMAGE; CT; OSTEOPOROSIS; IMPACT;
D O I
10.11607/jomi.6210
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To evaluate the relationship between mandibular bone structure parameters measured on preimplant cone beam computed tomography (CBCT) images and primary implant stability. Materials and Methods: Twenty-one hemimandibles were scanned on the 3D Accuitomo 170 CBCT. Next, an implant was placed in each hemimandible, after which insertion torque and implant stability quotient (ISQ) measurements were acquired. The following measurements were performed on the preimplant CBCT scans: bone surface, bone volume, fractal dimension, connectivity, trabecular thickness and spacing, and skeleton analysis. Measurements were performed using various regions of interest in the vicinity of the implant site. In addition, cortical thickness was measured. The correlation between bone structure parameters, insertion torque, and ISQ was calculated. Results: The overall correlation was low to medium (vertical bar R vertical bar = 0.002-0.723). For the bone around the entire implant site, the highest correlation with ISQ was found for skeleton analysis and trabecular thickness. The highest overall correlation between bone structure and ISQ was found in the coronal region. For insertion torque, no significant correlation was found for the bone around the entire implant; the highest overall correlation was found in the apical region. The highest number of significant correlations between bone structure and primary implant stability were found for trabecular thickness and fractal dimension. Conclusion: While each of the investigated bone structure parameters can have a predictive value in terms of primary implant stability, they should be measured at specific regions surrounding a planned implant site, and can provide complementary information regarding the local bone quality.
引用
收藏
页码:1257 / +
页数:45
相关论文
共 35 条
[1]   Smoking, Radiotherapy, Diabetes and Osteoporosis as Risk Factors for Dental Implant Failure: A Meta-Analysis [J].
Chen, Hui ;
Liu, Nizhou ;
Xu, Xinchen ;
Qu, Xinhua ;
Lu, Eryi .
PLOS ONE, 2013, 8 (08)
[2]   Dental Implants in the Elderly Population: A Long-Term Follow-up [J].
Compton, Sharon M. ;
Clark, Danielle ;
Chan, Stephanie ;
Kuc, Iris ;
Wubie, Berhanu A. ;
Levin, Liran .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (01) :164-170
[3]   BoneJ Free and extensible bone image analysis in ImageJ [J].
Doube, Michael ;
Klosowski, Michal M. ;
Arganda-Carreras, Ignacio ;
Cordelieres, Fabrice P. ;
Dougherty, Robert P. ;
Jackson, Jonathan S. ;
Schmid, Benjamin ;
Hutchinson, John R. ;
Shefelbine, Sandra J. .
BONE, 2010, 47 (06) :1076-1079
[4]   Impact of osteoporosis in dental implants: A systematic review [J].
Giro, Gabriela ;
Chambrone, Leandro ;
Goldstein, Abrao ;
Rodrigues, Jose Augusto ;
Zenobio, Elton ;
Feres, Magda ;
Figueiredo, Luciene Cristina ;
Cassoni, Alessandra ;
Shibli, Jamil Awad .
WORLD JOURNAL OF ORTHOPEDICS, 2015, 6 (02) :311-315
[5]   CBCT fractal dimension changes at the apex of immediate implants placed using undersized drilling [J].
Gonzalez-Martin, Oscar ;
Lee, Ernesto A. ;
Veltri, Mario .
CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (08) :954-957
[6]   Evaluation of osteoporosis in jaw bones using cone beam CT and dual-energy X-ray absorptiometry [J].
Gungor, Enes ;
Yildirim, Derya ;
Cevik, Remzi .
JOURNAL OF ORAL SCIENCE, 2016, 58 (02) :185-194
[7]   Survival of Branemark System Mk III implants and analysis of risk factors associated with implant failure [J].
Hasegawa, T. ;
Kawabata, S. ;
Takeda, D. ;
Iwata, E. ;
Saito, I. ;
Arimoto, S. ;
Kimoto, A. ;
Akashi, M. ;
Suzuki, H. ;
Komori, T. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2017, 46 (02) :267-273
[8]   Trabecular bone structural parameters evaluated using dental cone-beam computed tomography: cellular synthetic bones [J].
Ho, Jung-Ting ;
Wu, Jay ;
Huang, Heng-Li ;
Chen, Michael Y. C. ;
Fuh, Lih-Jyh ;
Hsu, Jui-Ting .
BIOMEDICAL ENGINEERING ONLINE, 2013, 12
[9]   Bone quality assessment based on cone beam computed tomography imaging [J].
Hua, Yan ;
Nackaerts, Olivia ;
Duyck, Joke ;
Maes, Frederik ;
Jacobs, Reinhilde .
CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (08) :767-771
[10]   Validating cone-beam computed tomography for peri-implant bone morphometric analysis [J].
Huang, Yan ;
Van Dessel, Jeroen ;
Depypere, Maarten ;
EzEldeen, Mostafa ;
Iliescu, Alexandru Andrei ;
Dos Santos, Emanuela ;
Lambrichts, Ivo ;
Liang, Xin ;
Jacobs, Reinhilde .
BONE RESEARCH, 2014, 2