Characterization of proton pencil beam scanning and passive beam using a high spatial resolution solid-state microdosimeter

被引:56
|
作者
Tran, Linh T. [1 ]
Chartier, Lachlan [1 ]
Bolst, David [1 ]
Pogossov, Alex [1 ]
Guatelli, Susanna [1 ]
Petasecca, Marco [1 ]
Lerch, Michael L. F. [1 ]
Prokopovich, Dale A. [2 ]
Reinhard, Mark I. [2 ]
Clasie, Benjamin [3 ]
Depauw, Nicolas [3 ]
Kooy, Hanne [3 ]
Flanz, Jacob B. [3 ]
McNamara, Aimee [3 ]
Paganetti, Harald [3 ]
Beltran, Chris [4 ]
Furutani, Keith [4 ]
Perevertaylo, Vladimir L. [5 ]
Jackson, Michael [6 ]
Rosenfeld, Anatoly B. [1 ]
机构
[1] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW, Australia
[2] Australian Nucl Sci & Technol Org, Lucas Heights, Australia
[3] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
[4] Mayo Clin, Radiat Oncol, Rochester, MN USA
[5] SPA BIT, Kiev, Ukraine
[6] Prince Wales Hosp, Dept Radiat Oncol, Randwick, NSW 2031, Australia
基金
澳大利亚研究理事会;
关键词
3D sensitive volume; microdosimetry; pencil beam scanning (PBS); proton therapy; RBE; silicon on insulator (SOI); RELATIVE BIOLOGICAL EFFECTIVENESS; RADIATION-FIELDS; CELL-SURVIVAL; C-12; ION; RBE; SILICON; MODEL;
D O I
10.1002/mp.12563
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This work aims to characterize a proton pencil beam scanning (PBS) and passive double scattering (DS) systems as well as to measure parameters relevant to the relative biological effectiveness (RBE) of the beam using a silicon on insulator (SOI) microdosimeter with well-defined 3D sensitive volumes (SV). The dose equivalent downstream and laterally outside of a clinical PBS treatment field was assessed and compared to that of a DS beam. Methods: A novel silicon microdosimeter with well-defined 3D SVs was used in this study. It was connected to low noise electronics, allowing for detection of lineal energies as low as 0.15keV/m. The microdosimeter was placed at various depths in a water phantom along the central axis of the proton beam, and at the distal part of the spread-out Bragg peak (SOBP) in 0.5mm increments. The RBE values of the pristine Bragg peak (BP) and SOBP were derived using the measured microdosimetric lineal energy spectra as inputs to the modified microdosimetric kinetic model (MKM). Geant4 simulations were performed in order to verify the calculated depth-dose distribution from the treatment planning system (TPS) and to compare the simulated dose-mean lineal energy to the experimental results. Results: For a 131MeV PBS spot (124.6mm R-90 range in water), the measured dose-mean lineal energy (y(D)) over bar increased from 2 keV/mu m at the entrance to 8keV/m in the BP, with a maximum value of 10 keV/mu m at the distal edge. The derived RBE distribution for the PBS beam slowly increased from 0.970.14 at the entrance to 1.04 +/- 0.09 proximal to the BP, then to 1.1 +/- 0.08 in the BP, and steeply rose to 1.57 +/- 0.19 at the distal part of the BP. The RBE distribution for the DS SOBP beam was approximately 0.96 +/- 0.16 to 1.01 +/- 0.16 at shallow depths, and 1.01 +/- 0.16 to 1.28 +/- 0.17 within the SOBP. The RBE significantly increased from 1.29 +/- 0.17 to 1.43 +/- 0.18 at the distal edge of the SOBP. Conclusions: The SOI microdosimeter with its well-defined 3D SV has applicability in characterizing proton radiation fields and can measure relevant physical parameters to model the RBE with submillimeter spatial resolution. It has been shown that for a physical dose of 1.82Gy at the BP, the derived RBE based on the MKM model increased from 1.14 to 1.6 in the BP and its distal part. Good agreement was observed between the experimental and simulation results, confirming the potential application of SOI microdosimeter with 3D SV for quality assurance in proton therapy. (C) 2017 American Association of Physicists in Medicine
引用
收藏
页码:6085 / 6095
页数:11
相关论文
共 44 条
  • [31] An avoidance method to minimize dose perturbation effects in proton pencil beam scanning treatment of patients with small high-Z implants
    Fellin, Francesco
    Artoni, Manuel
    Righetto, Roberto
    Bellinzona, Valentina Elettra
    Widesott, Lamberto
    Dionisi, Francesco
    Farace, Paolo
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (14)
  • [32] Passive SOBP generation from a static proton pencil beam using 3D-printed range modulators for FLASH experiments
    Horst, Felix
    Beyreuther, Elke
    Bodenstein, Elisabeth
    Gantz, Sebastian
    Misseroni, Diego
    Pugno, Nicola M.
    Schuy, Christoph
    Tommasino, Francesco
    Weber, Uli
    Pawelke, Joerg
    FRONTIERS IN PHYSICS, 2023, 11
  • [33] Semi-automated IGRT QA using a cone-shaped scintillator screen detector for proton pencil beam scanning treatments
    Cai, Weixing
    Oesten, Hakan
    Clasie, Benjamin
    Winey, Brian
    Jee, Kyung-Wook
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (08)
  • [34] A machine learning-based framework for delivery error prediction in proton pencil beam scanning using irradiation log-files
    Maes, Dominic
    Bowen, Stephen R.
    Regmi, Rajesh
    Bloch, Charles
    Wong, Tony
    Rosenfeld, Anatoly
    Saini, Jatinder
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 78 : 179 - 186
  • [35] 4D dose calculation for pencil beam scanning proton therapy of pancreatic cancer using repeated 4DMRI datasets
    Dolde, Kai
    Naumann, Patrick
    David, Christian
    Gnirs, Regula
    Kachelriess, Marc
    Lomax, Antony John
    Saito, Nami
    Weber, Damien Charles
    Pfaffenberger, Asja
    Zhang, Ye
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (16)
  • [36] Direct ion-beam deposition of Ag nanoparticles using a solid-state silver ion source
    Zuo, Wenbin
    Pelenovich, Vasiliy
    Tolstogouzov, Alexander
    Zhang, Rui
    Zeng, Xiaomei
    Abudouwufu, Tushagu
    Zhang, Xiangyu
    Fu, Dejun
    VACUUM, 2021, 183
  • [37] Comprehensive characterization of proton pencil beam profiles using a novel couch-mounted 2D strip detector system
    Huang, Hsiao-Chieh
    Chen, Hsien-Hsin
    Lin, Chih-Hsun
    Chang, Fu-Xiong
    Kao, Wei-Heng
    Chen, Po-Jui
    Chao, Tsi-Chian
    RADIATION PHYSICS AND CHEMISTRY, 2025, 232
  • [38] Potential Therapeutic Improvements in Prostate Cancer Treatment Using Pencil Beam Scanning Proton Therapy with LETd Optimization and Disease-Specific RBE Models
    Vieceli, Michael
    Park, Jiyeon
    Hsi, Wen Chien
    Saki, Mo
    Mendenhall, Nancy P.
    Johnson, Perry
    Artz, Mark
    CANCERS, 2024, 16 (04)
  • [39] Three-dimensional dosimetry using multiple-energy delivery and a single-layer detector for quality assurance in proton pencil beam scanning
    Righetto, Roberto
    Fogazzi, Elena
    Tommasino, Francesco
    Farace, Paolo
    MEDICAL PHYSICS, 2025, 52 (03) : 1769 - 1778
  • [40] Design, Characterization, and Modeling for a Modular High-Resolution Solid-State X-Ray Image Intensifier (SSXII)
    Huang, Ying
    Qu, Bin
    Jain, Amit
    Kuhls-Gilcrist, Andrew T.
    Titus, Albert H.
    Cartwright, Alexander N.
    Bednarek, Daniel R.
    Rudin, Stephen
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (01) : 20 - 29