共 3 条
Ultra-short echo time magnetic resonance angiography using a modified signal targeting with alternative radio frequency spin labeling technique for detecting recanalized pulmonary arteriovenous malformation after coil embolization
被引:3
|作者:
Hamamoto, Kohei
[1
,2
]
Chiba, Emiko
[3
]
Oyama-Manabe, Noriko
[2
]
Shinmoto, Hiroshi
[1
]
机构:
[1] Natl Def Med Coll, Dept Radiol, 3-2 Namiki, Tokorozawa, Saitama 3598513, Japan
[2] Jichi Med Univ, Saitama Med Ctr, Dept Radiol, Omiya Ku, Saitama, Japan
[3] Natl Ctr Neurol & Psychiat, Natl Ctr Hosp, Dept Radiol, Kodaira, Tokyo, Japan
关键词:
pulmonary arteriovenous malformation;
signal targeting alternating radio frequency with asymmetric inversion slabs;
ultra-short echo time;
non-contrast-enhanced magnetic resonance angiography;
MR-ANGIOGRAPHY;
EMBOLOTHERAPY;
FEASIBILITY;
REPERFUSION;
CT;
D O I:
10.1177/20584601211057671
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
Pulmonary arteriovenous malformation (PAVM) is a rare vascular anomaly, for which transcatheter embolization with metallic coils is the standard of care. Although detecting recanalization after embolotherapy is crucial, direct visualization of residual flow with computed tomography or magnetic resonance (MR) imaging is generally difficult due to metal artifacts. We present a case of recanalized PAVM after coil embolization detected by ultra-short echo time MR angiography using a modified signal targeting with an alternative radio frequency spin labeling technique.