Shielding failure lightning protection of 500kV quadruple-circuit transmission lines on the same tower

被引:0
|
作者
Yu, Shifeng [1 ]
Ruan, Jiangjun [1 ]
机构
[1] Wuhan Univ, Sch Elect Engn, Wuhan 430072, Peoples R China
关键词
electric geometry model (EGM); ground obliquity; quadruple-circuit on the same tower; shielding failure; striking distance factor;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The paper analyzes the performance of shielding failure lightning protection of 500kV quadruple-circuit overhead ac transmission lines on the same tower with revised EGM method and discusses the shielding effect of ground wires to phase conductors. Calculating the shielding failure trip out rate and modeling reasonably based on the analysis of tower style. The relationships between trip out rate and the influence factors such as tower height, protection angle, ground obliquity and striking distance factor are achieved. A conclusion is drawn that the shielding failure rate will turn larger when tower height, protection angle, ground obliquity become larger and the striking distance factor becomes smaller. The calculation and analysis results show that negative protection angle and lower tower height are effective to improve the performance of shielding failure of 500kV quadruple-circuit transmission lines on the same tower.
引用
收藏
页码:1705 / 1708
页数:4
相关论文
共 50 条
  • [41] An Approach for Measuring the Zero Sequence Parameters of Mix-Voltage Quadruple-Circuit Transmission Lines on One Tower
    Ni S.
    Hu Z.
    Yang A.
    Fu C.
    Hu, Zhijian (zhijian_hu@163.com), 2018, China Machine Press (33): : 2468 - 2478
  • [42] Research on Electromagnetic Character of 500/220kV Mixed-voltage Quadruple-circuit Transmission Line
    Liu, Weidong
    Liu, Kun
    Pan, Mingjiu
    Xu, Gang
    2013 12TH INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING (EEEIC 2013), 2013, : 227 - 231
  • [43] Study on lightning performance for ±500 kV DC double circuit transmission lines
    Nie, Dingzhen
    Zhou, Peihong
    Dai, Min
    Wang, Dongmei
    Gaodianya Jishu/High Voltage Engineering, 2007, 33 (01): : 148 - 151
  • [44] Modeling and evaluation of shielding failure for multi-circuit transmission lines in different voltage levels on the same tower
    Liao, Minchuan
    Wang, Jingyi
    Li, Zhitai
    Pan, Chunping
    Dianwang Jishu/Power System Technology, 2013, 37 (09): : 2547 - 2552
  • [45] A cross-differential protection scheme for quadruple-circuit lines with asymmetric parameters
    Liu, Qi
    Tai, Nengling
    Fan, Chunju
    Yu, Zhongan
    Shang, Jin
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2016, 26 (08): : 1646 - 1660
  • [47] Conductor Arrangement and Phase Sequence Optimization Scheme for 500 kV Four-Circuit Transmission Lines on Same Tower
    Lu D.
    Lang X.
    Yang B.
    Li Z.
    Geng H.
    Energy Engineering: Journal of the Association of Energy Engineering, 2023, 120 (10): : 2287 - 2306
  • [48] The analysis of Body Surface Electric Field during Live Working on 500kV double-circuit lines on same tower
    Liu, Xiaqin
    Yang, Qi
    Li, Hui
    Chen, Jianping
    Li, Jinliang
    Xu, Li
    2016 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2016,
  • [49] Combinatorial Weighting Method for Lightning Transformation Effect Evaluation of 500kV Transmission Lines
    Duan, R. C.
    Wang, F. H.
    Liu, Y. D.
    Huang, H.
    2014 IEEE PES GENERAL MEETING - CONFERENCE & EXPOSITION, 2014,
  • [50] Analysis of Lightning Shielding Failure for 500-kV Overhead Transmission Lines Based on an Improved Leader Progression Model
    Wei, Bengang
    Fu, Zhengcai
    Yuan, Haiyan
    IEEE TRANSACTIONS ON POWER DELIVERY, 2009, 24 (03) : 1433 - 1440