The metal-organic framework HKUST-1 as efficient sorbent in a vortex-assisted dispersive micro solid-phase extraction of parabens from environmental waters, cosmetic creams, and human urine

被引:152
|
作者
Rocio-Bautista, Priscilla [1 ]
Martinez-Benito, Carla [2 ]
Pino, Veronica [1 ]
Pasan, Jorge [2 ]
Ayala, Juan H. [1 ]
Ruiz-Perez, Catalina [2 ]
Afonso, Ana M. [1 ]
机构
[1] Univ La Laguna, Dept Chem, Analyt Div, E-38206 Tenerife, Spain
[2] Univ La Laguna, Dept Phys, X Ray & Mol Mat Lab MATMOL, E-38206 Tenerife, Spain
关键词
Metal-organic frameworks; Dispersive solid-phase extraction; Micro-solid-phase extraction; Parabens; Personal care products; Vortex-assisted methods; Environmental waters; Cosmetic creams; Human urine; POLYCYCLIC AROMATIC-HYDROCARBONS; PERFORMANCE LIQUID-CHROMATOGRAPHY; PECTINATA MEDICINAL-PLANT; COORDINATION POLYMER; GAS-CHROMATOGRAPHY; MICROEXTRACTION; ADSORPTION; PESTICIDES; ADSORBENT; PRECONCENTRATION;
D O I
10.1016/j.talanta.2015.02.032
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Three metal-organic frameworks (MOFs), specifically HKUST-1, MOF-5, and MIL-53(AI), have been synthetized, characterized, studied and compared in a vortex-assisted dispersive micro-solid-phase extraction (VA-D-mu-SPE) procedure in combination with high-performance liquid chromatography (HPLC) with diode-array detection (DAD) for determining seven parabens in environmental waters (tap water, swimming pool water, and water coming from a spa pool), human urine (from two volunteers), and cosmetic creams (two commercial brands). Experimental parameters, such as nature and amount of MOF, sample volume, nature of elution solvent and its amount, vortex and centrifugation time, among others, were properly optimized. HKUST-1 was the most adequate MOF to work with. Detection limits for the overall method down to 0.1 mu g L-1 for butylparaben (BPB) and benzylparaben (BzPB) were obtained, with determination coefficients (R-2) higher than 0.9966 for a range of 0.5-147 mu g L-1 (depending on the paraben), average relative recoveries (RR, in %) of 803% at the low spiked level (7 mu g L-1), and relative standard deviation (RSD) values below 10% also at the low spiked level. The strength of the affinity between HKUST-1 and parabens was evaluated, and it ranged from 33.5% for isopropylparaben (iPPB) to 77.0% for isobutylparaben (iBPB). When analyzing complex environmental waters, RR values of 78%, inter-day precision values (as RSD) lower than 15%, and intra-day precision values lower than 7.8% were obtained, despite the observed matrix effect. When analyzing cosmetic creams, parabens were detected, with contents ranging from 0.14 +/- 0.01 mu g g(-1) for EPB in the healing cream analyzed to 1.12 +/- 0.07 mg g(-1) for MPB in the mask cream analyzed, with precision values (RSD) lower than 12% and RR values from 63.7% for propylparaben (PPB) to 121% for iPPB. When analyzing human urine, no parabens were detected but the method could be performed with RSD values lower than 19%. These results show the adequateness of MOFs as sorbents in VA-D-mu-SPE procedures despite sample complexity. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:13 / 20
页数:8
相关论文
共 50 条
  • [21] Application of a Pillared-Layer Zn-Triazolate Metal-Organic Framework in the Dispersive Miniaturized Solid-Phase Extraction of Personal Care Products from Wastewater Samples
    Gonzalez-Hernandez, Providencia
    Lago, Ana B.
    Pasan, Jorge
    Ruiz-Perez, Catalina
    Ayala, Juan H.
    Afonso, Ana M.
    Pino, Veronica
    MOLECULES, 2019, 24 (04):
  • [22] Metal organic framework based carbon porous as an efficient dispersive solid phase extraction adsorbent for analysis of methamphetamine from urine matrix
    Taghvimi, Arezou
    Tabrizi, Ahad Bavili
    Dastmalchi, Siavoush
    Javadzadeh, Yousef
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2019, 1109 : 149 - 154
  • [23] Vortex-Assisted Dispersive Solid-Phase Microextraction Using Ionic Liquid-Modified Metal-Organic Frameworks of PAHs from Environmental Water, Vegetable, and Fruit Juice Samples
    A. Nasrollahpour
    S. E. Moradi
    M. J. Baniamerian
    Food Analytical Methods, 2017, 10 : 2815 - 2826
  • [24] Dimethyldioctadecylanimonium bentonite immobilized magnetic chitosan nanoparticles as an efficient adsorbent for vortex-assisted magnetic dispersive micro-solid-phase extraction of celecoxib from human breast milk, plasma and urine samples
    Majidi, Seyedeh Maedeh
    Hadjmohammadi, Mohammad Reza
    BIOMEDICAL CHROMATOGRAPHY, 2020, 34 (09)
  • [25] Dispersive solid-phase extraction of selected nitrophenols from environmental water samples using a zirconium-based amino-tagged metal-organic framework nanosorbent
    Salimi, Maryam
    Behbahani, Mohammad
    Sobhi, Hamid Reza
    Ghambarian, Mahnaz
    Esrafili, Ali
    JOURNAL OF SEPARATION SCIENCE, 2018, 41 (22) : 4159 - 4166
  • [26] Zirconium (IV)-based metal organic framework (UIO-67) as efficient sorbent in dispersive solid phase extraction of plant growth regulator from fruits coupled with HPLC fluorescence detection
    Liu, Lijie
    Xia, Lian
    Wu, Chuanxiang
    Qu, Fengli
    Li, Guoliang
    Sun, Zhiwei
    You, Jinmao
    TALANTA, 2016, 154 : 23 - 30
  • [27] Magnetic porous carbon derived from a metal-organic framework as a magnetic solid-phase extraction adsorbent for the extraction of sex hormones from water and human urine
    Ma, Ruiyang
    Hao, Lin
    Wang, Junmin
    Wang, Chun
    Wu, Qiuhua
    Wang, Zhi
    JOURNAL OF SEPARATION SCIENCE, 2016, 39 (18) : 3571 - 3577
  • [28] Magnetic porous carbon derived from a bimetallic metal-organic framework for magnetic solid-phase extraction of organochlorine pesticides from drinking and environmental water samples
    Liu, Yaxi
    Gao, Zongjun
    Wu, Ri
    Wang, Zhenhua
    Chen, Xiangfeng
    Chan, T. -W. Dominic
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1479 : 55 - 61
  • [29] HKUST-1 metal-organic framework for dispersive solid phase extraction of 2-methyl-4-chlorophenoxyacetic acid (MCPA) prior to its determination by ion mobility spectrometry
    Masoumeh Mohammadnejad
    Zahra Gudarzi
    Shokoofeh Geranmayeh
    Vahideh Mahdavi
    Microchimica Acta, 2018, 185
  • [30] Metal organic framework/clay composite for micro-dispersive solid-phase extraction of sulfonamides and penicillins in milk, and synthetic urine solution coupling with HPLC/DAD detection
    Aldoori, Mahmood Saad
    Merdivan, Melek
    Tagac, Aylin Altinisik
    MICROCHEMICAL JOURNAL, 2023, 184