Emission characteristics of filterable particulate matter and condensable particulate matter from coal-fired power plants

被引:7
作者
Yang, Yonglong [1 ,2 ]
Su, Qiufeng [1 ]
Zheng, Chenghang [1 ]
Zhang, Yang [2 ]
Wang, Yifan [1 ]
Guo, Dong [2 ]
He, Yongbing [2 ]
Zhu, Yue [2 ]
机构
[1] Zhejiang Univ, State Key Lab Clean Energy Utilizat, State Environm Protect Engn Ctr Coal Fired Air Po, 38 Zheda Rd, Hangzhou 310027, Peoples R China
[2] Huadian Elect Power Res Inst Co LTD, 2 Xiyuanjiu Rd, Hangzhou 310030, Peoples R China
基金
中国国家自然科学基金;
关键词
Air pollution control devices; Condensable particulate matter; Inorganic ions; Emission characteristics; Coal-fired power plant; SO3; POLLUTION; REMOVAL; AEROSOL;
D O I
10.1016/j.csite.2022.102145
中图分类号
O414.1 [热力学];
学科分类号
摘要
Particulate matter (PM) emission has been widely concerned all over the world. The formation of condensable particulate matter (CPM) was affected by atmospheric temperature. An optimal-designed sampling device and monitoring method for particulate matter in high-humidity flue gas were applied to the particulate matter emission concentration of 12 ultra-low emission coal-fired units. The emission levels and composition characteristics of particulate matter and main inorganic ions in the flue gas were analyzed and evaluated. The results showed that the filterable particulate matter (FPM) concentration range was 0.81-7.52 mg/m(3), and the condensable particulate matter concentration range was 1.10-12.25 mg/m(3). The emission characteristics of CPM/FPM was significantly affected by different air pollution control devices. Preferable emission reduction result of condensable particulate matter may be realized by units equipping wet limestone-gypsum flue gas desulfurization and wet electrostatic precipitator. The certain correlation was showed between CPM/FPM and ash content. The inorganic ion concentration range was 1104-8240 mu g/m(3) in condensable particulate matter. Ca2+ concentration accounted for more than 45% of the cation concentration, and SO42- concentration accounted for up to 97.81% of the anion concentration in CPM.
引用
收藏
页数:10
相关论文
共 42 条
  • [1] Chang Q., 2017, MULTIPROCESS ENHANCE
  • [2] China Electricity Council, China power industry annual development report 2023
  • [3] In-stack condensible particulate matter measurements and issues
    Corio, LA
    Sherwell, J
    [J]. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2000, 50 (02): : 207 - 218
  • [4] A Clearance Period after Soluble Lead Nanoparticle Inhalation Did Not Ameliorate the Negative Effects on Target Tissues Due to Decreased Immune Response
    Dumkova, Jana
    Smutna, Tereza
    Vrlikova, Lucie
    Docekal, Bohumil
    Kristekova, Daniela
    Vecera, Zbynek
    Husakova, Zuzana
    Jakesova, Veronika
    Jedlickova, Adriena
    Mikuska, Pavel
    Alexa, Lukas
    Coufalik, Pavel
    Tvrdonova, Michaela
    Krumal, Kamil
    Vaculovic, Tomas
    Kanicky, Viktor
    Hampl, Ales
    Buchtova, Marcela
    [J]. INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2020, 21 (22) : 1 - 27
  • [5] EPRI, 2011, SULF AC STUD REM FGD
  • [6] Comparative study on the characteristics of condensable particulate matter emitted from three kinds of coal
    Feng, Yupeng
    Li, Yuzhong
    Zhang, Xiaoyu
    Su, Shiqian
    Zhang, Zhuping
    Gan, Zongwei
    Dong, Yong
    [J]. ENVIRONMENTAL POLLUTION, 2021, 270 (270)
  • [7] Critical review of condensable particulate matter
    Feng, Yupeng
    Li, Yuzhong
    Cui, Lin
    [J]. FUEL, 2018, 224 : 801 - 813
  • [8] [葛敬 Ge Jing], 2018, [化工学报, CIESC Journal], V69, P2829
  • [9] Emission Concentration and Characteristics of Particulate Matter and Water-Soluble Ions in Exhaust Gas of Typical Combustion Sources with Ultra-Low Emission
    Hu Y.-Q.
    Wang Z.
    Guo J.-H.
    Feng Y.-J.
    Ding M.-M.
    Yan X.
    [J]. Huanjing Kexue/Environmental Science, 2021, 42 (05): : 2159 - 2168
  • [10] Hu Yue-qi, 2015, Huanjing Kexue, V36, P1966