A regenerating ultrasensitive electrochemical impedance immunosensor for the detection of adenovirus

被引:46
作者
Lin, Donghai [1 ]
Tang, Thompson [2 ]
Harrison, D. Jed [1 ,3 ]
Lee, William E. [2 ]
Jemere, Abebaw B. [3 ]
机构
[1] Univ Alberta, Dept Chem, Edmonton, AB T6G 2G2, Canada
[2] Def Res & Dev Canada, Suffield Res Ctr, Medicine Hat, AB T1A 8K6, Canada
[3] Natl Res Council Canada, Natl Inst Nanotechnol, Edmonton, AB T6G 2M9, Canada
关键词
Self-assembly; Electrochemical impedance spectroscopy; Electrode regeneration; Adenovirus; Gold nanoparticles modified electrodes; SELF-ASSEMBLED MONOLAYERS; EFFICIENT ELECTRON-TRANSFER; GOLD ELECTRODES; METAL NANOPARTICLES; PATHOGEN DETECTION; VIRUS; ACID; DESORPTION; STABILITY; IMMOBILIZATION;
D O I
10.1016/j.bios.2014.12.032
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We report on the development of a regenerable sensitive immunosensor based on electrochemical impedance spectroscopy for the detection of type 5 adenovirus. The multi-layered immunosensor fabrication involved successive modification steps on gold electrodes: (i) modification with self-assembled layer of 1,6-hexanedithiol to which gold nanoparticles were attached via the distal thiol groups, (ii) formation of self-assembled monolayer of 11-mercaptoundecanoic acid onto the gold nanoparticles, (iii) covalent immobilization of monoclonal anti-adenovirus 5 antibody, with EDC/NHS coupling reaction on the nanoparticles, completing the immunosensor. The immunosensor displayed a very good detection limit of 30 virus particles/ml and a wide linear dynamic range of 10(5). An electrochemical reductive desorption technique was employed to completely desorb the components of the immunosensor surface, then re-assemble the sensing layer and reuse the sensor. On a single electrode, the multi-layered immunosensor could be assembled and disassembled at least 30 times with 87% of the original signal intact. The changes of electrode behavior after each assembly and desorption processes were investigated by cyclic voltammetry, electrochemical impedance spectroscopy and X-ray photoelectron spectroscopy techniques. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:129 / 134
页数:6
相关论文
共 50 条
  • [1] Electrochemical immunosensor modified with self-assembled monolayer of 11-mercaptoundecanoic acid on gold electrodes for detection of benzo[a]pyrene in water
    Ahmad, Azrilawani
    Moore, Eric
    [J]. ANALYST, 2012, 137 (24) : 5839 - 5844
  • [2] Detection of influenza virus: traditional approaches and development of biosensors
    Amano, Y
    Cheng, Q
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 381 (01) : 156 - 164
  • [3] The Influence of Organic-Film Morphology on the Efficient Electron Transfer at Passivated Polymer-Modified Electrodes to which Nanoparticles are Attached
    Barfidokht, Abbas
    Ciampi, Simone
    Luais, Erwann
    Darwish, Nadim
    Gooding, J. Justin
    [J]. CHEMPHYSCHEM, 2013, 14 (10) : 2190 - 2197
  • [4] Distance-Dependent Electron Transfer at Passivated Electrodes Decorated by Gold Nanoparticles
    Barfidokht, Abbas
    Ciampi, Simone
    Luais, Erwann
    Darwish, Nadim
    Gooding, J. Justin
    [J]. ANALYTICAL CHEMISTRY, 2013, 85 (02) : 1073 - 1080
  • [5] Distance-independent charge-transfer resistance at gold electrodes modified by thiol monolayers and metal nanoparticles
    Bradbury, Christopher R.
    Zhao, Jianjun
    Fermin, David J.
    [J]. JOURNAL OF PHYSICAL CHEMISTRY C, 2008, 112 (27) : 10153 - 10160
  • [6] Formation and removal of alkylthiolate self-assembled monolayers on gold in aqueous solutions
    Canaria, CA
    So, J
    Maloney, JR
    Yu, CJ
    Smith, JO
    Roukes, ML
    Fraser, SE
    Lansford, R
    [J]. LAB ON A CHIP, 2006, 6 (02) : 289 - 295
  • [7] Novel impedimetric immunosensor for the detection and quantitation of Adenovirus using reduced antibody fragments immobilized onto a conducting copolymer surface
    Caygill, Rebecca L.
    Hodges, Christopher S.
    Holmes, Joanne L.
    Higson, Seamus P. J.
    Blair, G. Eric
    Millner, Paul A.
    [J]. BIOSENSORS & BIOELECTRONICS, 2012, 32 (01) : 104 - 110
  • [8] A review on viral biosensors to detect human pathogens
    Caygill, Rebecca L.
    Blair, G. Eric
    Millner, Paul A.
    [J]. ANALYTICA CHIMICA ACTA, 2010, 681 (1-2) : 8 - 15
  • [9] Adenovirus infections in stem cell transplant recipients: Recent developments in understanding of pathogenesis, diagnosis and management
    Chakrabarti, S
    Milligan, DW
    Moss, PAH
    Mautner, V
    [J]. LEUKEMIA & LYMPHOMA, 2004, 45 (05) : 873 - 885
  • [10] Electrochemical Impedance Spectroscopy
    Chang, Byoung-Yong
    Park, Su-Moon
    [J]. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY, VOL 3, 2010, 3 : 207 - 229