Spectral-Domain Optical Coherence Tomography and Scanning Laser Polarimetry in Glaucoma Diagnosis

被引:17
|
作者
Lee, Suhwan [1 ]
Sung, Kyung Rim [1 ]
Cho, Jung Woo [1 ]
Cheon, Mi Hyun [1 ]
Kang, Sung Yong [1 ]
Kook, Michael S. [1 ]
机构
[1] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Ophthalmol, Seoul 138736, South Korea
关键词
glaucoma; scanning laser polarimetry; spectral domain OCT; LAYER THICKNESS MEASUREMENTS; VARIABLE CORNEAL COMPENSATION; NERVE-FIBER THICKNESS; GDX-VCC; STRATUS OCT; REPRODUCIBILITY; VARIABILITY; EYES;
D O I
10.1007/s10384-010-0870-5
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate glaucoma diagnostic capability of the retinal nerve fiber layer (RNFL) imaging by spectral-domain optical coherence tomography (Cirrus OCT) and scanning laser polarimetry (GDx VCC). Methods: We imaged 88 glaucomatous and 77 healthy eyes using both devices. Areas under the receiver-operating characteristic curves (area under the curves, AUCs) and sensitivities at fixed specificities of average, superior, and inferior RNFL thickness were compared. Likelihood ratios (LRs) and diagnostic agreement based on normative classifications yielded by both devices were determined. Results: The best performing parameter was the nerve fiber indicator (NFI) in GDx VCC and inferior RNFL thickness in Cirrus OCT (AUC = 0.912, 0.961, P = 0.045). The AUCs of the Cirrus OCT were significantly higher than those of GDx VCC in all parameters. Most of the parameters in Cirrus OCT were more sensitive than GDx VCC in the detection of glaucoma at fixed specificity values. Cirrus OCT had an infinite LR with abnormal classification results in both average and superior RNFL thickness. There was good agreement between the two instruments with respect to abnormal classifications (kappa, 0.611-0.766) Conclusion: Both Cirrus OCT and GDx VCC RNFL measurements showed good glaucoma diagnostic capabilities. Cirrus OCT showed higher sensitivities than GDx VCC. Jpn J Ophthalmol 2010;54:544-549 (C) Japanese Ophthalmological Society 2010
引用
收藏
页码:544 / 549
页数:6
相关论文
共 50 条
  • [31] Reproducibility of Spectral-Domain Optical Coherence Tomography RNFL Map for Glaucomatous and Fellow Normal Eyes in Unilateral Glaucoma
    Suh, Min Hee
    Yoo, Byeong Wook
    Park, Ki Ho
    Kim, Hyunjoong
    Kim, Hee Chan
    JOURNAL OF GLAUCOMA, 2015, 24 (03) : 238 - 244
  • [32] Observations by Spectral-Domain Optical Coherence Tomography Combined with Simultaneous Scanning Laser Ophthalmoscopy: Imaging of the Vitreous
    Mojana, Francesca
    Kozak, Igor
    Oster, Stephen F.
    Cheng, Lingyun
    Bartsch, Dirk-Uwe G.
    Brar, Manpreet
    Yuson, Ritchie M.
    Freeman, William R.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2010, 149 (04) : 641 - 650
  • [33] Imaging of the retinal nerve fibre layer with spectral domain optical coherence tomography for glaucoma diagnosis
    Sung, Kyung Rim
    Kim, Jong S.
    Wollstein, Gadi
    Folio, Lindsey
    Kook, Michael S.
    Schuman, Joel S.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2011, 95 (07) : 909 - 914
  • [34] Scanning laser polarimetry and spectral domain optical coherence tomography for the detection of retinal changes in Parkinson's disease
    Stemplewitz, Birthe
    Keserue, Matthias
    Bittersohl, Diana
    Buhmann, Carsten
    Skevas, Christos
    Richard, Gisbert
    Hassenstein, Andrea
    ACTA OPHTHALMOLOGICA, 2015, 93 (08) : E672 - E677
  • [35] Spectral-Domain Optical Coherence Tomography of β-zone Peripapillary Atrophy: Influence of Myopia and Glaucoma
    Hayashi, Keiko
    Tomidokoro, Atsuo
    Lee, Kelvin Y. C.
    Konno, Shinsuke
    Saito, Hitomi
    Mayama, Chihiro
    Aihara, Makoto
    Iwase, Aiko
    Araie, Makoto
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (03) : 1499 - 1505
  • [36] Retinal nerve fibre layer thickness measurements in childhood glaucoma: the role of scanning laser polarimetry and optical coherence tomography
    Lever, Mael
    Halfwassen, Christian
    Unterlauft, Jan Darius
    Bechrakis, Nikolaos E.
    Manthey, Anke
    Boehm, Michael R. R.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2021, 259 (12) : 3777 - 3786
  • [37] Diagnosing Glaucoma With Spectral-Domain Optical Coherence Tomography Using Deep Learning Classifier
    Lee, Jinho
    Kim, Young Kook
    Park, Ki Ho
    Jeoung, Jin Wook
    JOURNAL OF GLAUCOMA, 2020, 29 (04) : 287 - 294
  • [38] Structure-Function Relationship in Glaucoma Using Spectral-Domain Optical Coherence Tomography
    Rao, Harsha L.
    Zangwill, Linda M.
    Weinreb, Robert N.
    Leite, Mauro T.
    Sample, Pamela A.
    Medeiros, Felipe A.
    ARCHIVES OF OPHTHALMOLOGY, 2011, 129 (07) : 864 - 871
  • [39] Optic Disc Vascularization in Glaucoma: Value of Spectral-Domain Optical Coherence Tomography Angiography
    Leveque, Pierre-Maxime
    Zeboulon, Pierre
    Brasnu, Emmanuelle
    Baudouin, Christophe
    Labbe, Antoine
    JOURNAL OF OPHTHALMOLOGY, 2016, 2016
  • [40] Glaucoma progression analysis by Spectral-Domain Optical Coherence Tomography (SD-OCT)
    Renard, J-P
    Fenolland, R.
    Giraud, J-M
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2019, 42 (05): : 499 - 516