Degradation of refractory organic compounds from dinitrodiazophenol containing industrial wastewater through UV/H2O2 and UV/PS processes

被引:15
|
作者
Ran, Gang [1 ]
Li, Qibin [1 ]
机构
[1] Southwest Jiaotong Univ, Fac Geosci & Environm Engn, Chengdu 611756, Peoples R China
关键词
DDNP; Refractory organic compounds; UV/H2O2; UV/PS; BISPHENOL-A DEGRADATION; UV/PERSULFATE SYSTEMS; ACTIVATED PERSULFATE; REACTION-KINETICS; RATE CONSTANTS; P-NITROPHENOL; OXIDATION; PEROXYMONOSULFATE; PERFORMANCE; RADICALS;
D O I
10.1007/s11356-019-07367-1
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this study, refractory organic compounds from dinitrodiazophenol (DDNP) containing industrial wastewater were degraded through two ultraviolet (UV)-based advanced oxidation processes: UV/hydrogen peroxide (UV/H2O2) and UV/potassium persulfate (UV/PS) processes. In both processes, the synergistic effects, operational parameters (i.e., oxidant dosage and initial pH value), and pseudo first-order constant k were systematically studied. Moreover, the reactive oxygen species formed in the UV/H2O2 and UV/PS processes were identified, and the degradation of refractory organic compounds was characterized through UVvisible spectra analysis. The improvement in biodegradability of DDNP industrial wastewater after treatment by different processes was compared. Both the UV/H2O2 (synergistic coefficient F = 61.34) and UV/PS (synergistic coefficient F = 54.85) processes showed significant, highly synergistic effects. The increase in oxidant dosage was beneficial in organic compound removal in both the UV/H2O2 and UV/PS processes, but excessive H2O2 showed a stronger inhibition of the increase in organic compound removal than that in the UV/PS process. In addition, an acidic environment was more conducive to organic compound degradation in the UV/H2O2 process, whereas the initial pH value had less of an influence on the UV/PS process. Under optimal conditions for the UV/H2O2 and UV/PS processes, the CN and COD removal efficiencies were 99.71%, 66.35%, 99.69%, and 70.81%, respectively, and the k values for COD removal were 0.0804 and 0.0824 min-1. Tests to identify reactive oxygen species showed that the hydroxyl radical was the predominant oxidizing species in the UV/H2O2 process, whereas the hydroxyl and sulfate radicals were both identified in the UV/PS process, and the sulfate radical contributed the most to the degradation of organic compounds. In addition, spectrum analysis revealed that the complex structure (e.g., benzene ring, nitro group, and diazo group) of refractory organic compounds from DDNP industrial wastewater was effectively destroyed by the UV/H2O2 and UV/ PS processes, and both processes improved the biodegradability (biochemical oxygen demand for 5 days/chemical oxygen demand (BOD5/COD)) of DDNP industrial wastewater from 0.052 to 0.665 and 0.717, respectively. Overall, both the UV/ H2O2 and UV/PS processes effectively degraded the refractory organic compounds from DDNP industrial wastewater, and the UV/PS process exhibited a higher organic compound removal efficiency and better applicability.
引用
收藏
页码:6042 / 6051
页数:10
相关论文
共 50 条
  • [41] Degradation kinetics of caffeine in water by UV/H2O2 and UV/TiO2
    Rendel, Pedro M.
    Rytwo, Giora
    DESALINATION AND WATER TREATMENT, 2020, 173 : 231 - 242
  • [42] Degradation of 40 selected pharmaceuticals by UV/H2O2
    Wols, B. A.
    Hofman-Caris, C. H. M.
    Harmsen, D. J. H.
    Beerendonk, E. F.
    WATER RESEARCH, 2013, 47 (15) : 5876 - 5888
  • [43] Degradation of 17 Benzodiazepines by the UV/H2O2 Treatment
    You, Wen-Dan
    Ye, Pu
    Yang, Bin
    Luo, Xin
    Fang, Jie
    Mai, Zi-Tian
    Sun, Jian-Liang
    FRONTIERS IN ENVIRONMENTAL SCIENCE, 2021, 9
  • [44] Photodegradation of the antineoplastic cyclophosphamide: A comparative study of the efficiencies of UV/H2O2, UV/Fe2+/H2O2 and UV/TiO2 processes
    Lutterbeck, Carlos Alexandre
    Machado, Enio Leandro
    Kammerer, Klaus
    CHEMOSPHERE, 2015, 120 : 538 - 546
  • [45] Use of Fenton reagent and the UV/H2O2 method for removal of organic compounds from wastewater from 2-ethylhexyl nitrate production
    Salwiczek, Szymon
    Barbusinski, Krzysztof
    PRZEMYSL CHEMICZNY, 2013, 92 (04): : 463 - 468
  • [46] Slaughterhouse wastewater treatment by combined anaerobic baffled reactor and UV/H2O2 processes
    Cao, Weihua
    Mehrvar, Mehrab
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2011, 89 (7A) : 1136 - 1143
  • [47] Degradation of ofloxacin in aqueous solution with UV/H2O2
    Xue, Honghai
    Hu, Chun
    Peng, Juwei
    Wang, Lining
    Wang, Ying
    Ji, Ning
    Wen, Xue
    DESALINATION AND WATER TREATMENT, 2017, 72 : 386 - 393
  • [48] Degradation of Calmagite by H2O2/UV/US, H2O2/US, H2O2, and US process
    Menek, Necati
    Ugurlar, Ceren
    Ucarh, Okan
    Karaman, Yeliz
    Omanovic, Sasha
    Ghasemian, Saloumeh
    ALEXANDRIA ENGINEERING JOURNAL, 2022, 61 (05) : 4127 - 4135
  • [49] Change in haloacetic acid formation potential during UV and UV/H2O2 treatment of model organic compounds
    Sakai, Hiroshi
    Autin, Olivier
    Parsons, Simon
    CHEMOSPHERE, 2013, 92 (06) : 647 - 651
  • [50] Modelling micropollutant degradation in UV/H2O2 systems: Lagrangian versus Eulerian method
    Wols, B. A.
    Hofman-Caris, C. H. M.
    CHEMICAL ENGINEERING JOURNAL, 2012, 210 : 289 - 297