One-year follow-up of conduction disturbances following transcatheter aortic valve implantation

被引:9
|
作者
Salizzoni, Stefano [1 ]
Anselmino, Matteo [2 ]
Fornengo, Cristina [2 ]
Giordana, Francesca [2 ]
La Torre, Michele [1 ]
Moretti, Claudio [2 ]
D'Amico, Maurizio [3 ]
Omede, Pierluigi [2 ]
Marra, Sebastiano [3 ]
Rinaldi, Mauro [1 ]
Gaita, Fiorenzo [2 ]
机构
[1] Univ Turin, Dept Surg Sci, Div Cardiac Surg, Turin, Italy
[2] Univ Turin, Dept Med Sci, Div Cardiol, Turin, Italy
[3] Citta Salute & Sci Hosp, Div Cardiol, Turin, Italy
关键词
aortic stenosis; complications; conduction disturbances; follow-up; pacemaker; transcatheter aortic valve implantation; BUNDLE-BRANCH BLOCK; ATRIOVENTRICULAR-BLOCK; MEDTRONIC COREVALVE; PERMANENT PACEMAKER; HEART-BLOCK; REPLACEMENT; PREDICTORS; STENOSIS; SYSTEM; ABNORMALITIES;
D O I
10.2459/JCM.0000000000000179
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
AimsTo describe the postprocedural and 1-year follow-up incidence of heart conduction disturbances in patients with severe symptomatic aortic stenosis undergoing transcatheter aortic valve implantation (TAVI).MethodsNinety-five patients were enrolled from 2008 to 2011 (mean age 81.87.2 years, 63.1% women). Clinical and ECG data were recorded at admission, discharge, and 3, 6 and 12 months following TAVI.ResultsFifty-seven Edwards SAPIEN (31 transapical, 26 transfemoral) and 38 transfemoral CoreValve implants were used. Two (2.1%) patients died during the procedure and 11 (11.6%) patients received a pacemaker prior to discharge (7 CoreValve, 3 transapical, 1 transfemoral SAPIEN; P=0.18). Among the surviving patients not receiving a pacemaker, TAVI increased the PQ interval (176 +/- 29 vs. 188 +/- 36 ms; P=0.001), QRS width (90 +/- 15 vs. 108 +/- 26 ms; P<0.001), and first-grade atrioventricular block (17 vs. 29%; P<0.001). Postprocedural complete left bundle branch block was reported most in transapical (from 10 to 36%; P=0.01) and CoreValve (from 8 to 64%; P<0.001) recipients compared to the transfemoral SAPIEN group. At the 12-month follow-up, 24 (25.3%) patients had died [two (2.1%) sudden deaths] and four (4.2%) required pacemaker implantation. Among the survivors not receiving a pacemaker at the 1-year follow-up, the PQ interval (178 +/- 27 vs. 188 +/- 36ms; P=0.39) remained unchanged in the ECG, whereas the QRS width (100 +/- 22 vs. 108 +/- 26 ms; P=0.008) decreased compared to measurements taken at discharge.ConclusionConduction disturbances following TAVI primarily develop during hospitalization and subsequently stabilize. However, the small percentage of patients suffering sudden death or pacemaker implantation requires attention.
引用
收藏
页码:296 / 302
页数:7
相关论文
共 50 条
  • [21] Long-term Follow-up After Transcatheter Aortic Valve Implantation for Severe Aortic Stenosis
    Salinas, Pablo
    Moreno, Raul
    Calvo, Luis
    Sanchez-Recalde, Angel
    Jimenez-Valero, Santiago
    Galeote, Guillermo
    Lopez-Fernandez, Teresa
    Ramirez, Ulises
    Riera, Luis
    Plaza, Ignacio
    Moreno, Isidro
    Maria Mesa, Jose
    Luis Lopez-Sendon, Jose
    REVISTA ESPANOLA DE CARDIOLOGIA, 2016, 69 (01): : 37 - 44
  • [22] Outcomes of Acute Conduction Abnormalities Following Transcatheter Aortic Valve Implantation With a Balloon Expandable Valve and Predictors of Delayed Conduction System Abnormalities in Follow-up
    McCaffrey, James A.
    Alzahrani, Talal
    Datta, Tanuka
    Solomon, Allen J.
    Mercader, Marco
    Mazhari, Ramesh
    Nagy, Christian
    Reiner, Jonathan S.
    Tracy, Cynthia M.
    AMERICAN JOURNAL OF CARDIOLOGY, 2019, 123 (11) : 1845 - 1852
  • [23] One-Year Results of Transcatheter Aortic Valve Implantation in Severe Symptomatic Aortic Valve Stenosis
    Gotzmann, Michael
    Bojara, Waldemar
    Lindstaedt, Michael
    Ewers, Aydan
    Boesche, Leif
    Germing, Alfried
    Lawo, Thomas
    Bechtel, Matthias
    Laczkovics, Axel
    Muegge, Andreas
    AMERICAN JOURNAL OF CARDIOLOGY, 2011, 107 (11) : 1687 - 1692
  • [24] Timing of Onset and Outcome of New Conduction Abnormalities Following Transcatheter Aortic Valve Implantation: Role of Balloon Aortic Valvuloplasty
    Campelo-Parada, Francisco
    Nombela-Franco, Luis
    Urena, Marina
    Regueiro, Ander
    Jimenez-Quevedo, Pilar
    Del Trigo, Maria
    Chamandi, Chekrallah
    Rodriguez-Gabella, Tania
    Auffret, Vincent
    Altisent, Omar Abdul-Jawad
    DeLarochelliere, Robert
    Paradis, Jean-Michel
    Dumont, Eric
    Philippon, Francois
    Perez-Castellano, Nicasio
    Puri, Rishi
    Macaya, Carlos
    Rodes-Cabau, Josep
    REVISTA ESPANOLA DE CARDIOLOGIA, 2018, 71 (03): : 162 - 169
  • [25] Management of Conduction Disturbances Associated With Transcatheter Aortic Valve Replacement JACC Scientific Expert Panel
    Rodes-Cabau, Josep
    Ellenbogen, Kenneth A.
    Krahn, Andrew D.
    Latib, Azeem
    Mack, Michael
    Mittal, Suneet
    Muntane-Carol, Guillem
    Nazif, Tamim M.
    Sondergaard, Lars
    Urena, Marina
    Windecker, Stephan
    Philippon, Francois
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 74 (08) : 1086 - 1106
  • [26] Can we reduce conduction disturbances following transcatheter aortic valve replacement?
    Garcia, Alberto Alperi
    Muntane-Carol, Guillem
    Junquera, Lucia
    del Val, David
    Faroux, Laurent
    Philippon, Francois
    Rodes-Cabau, Josep
    EXPERT REVIEW OF MEDICAL DEVICES, 2020, 17 (04) : 309 - 322
  • [27] One-Year Outcomes of Transcatheter Aortic Valve Implantation Using the Direct Aortic Approach
    Bruschi, Giuseppe
    Branny, Marian
    Schiltgen, Molly
    Ettori, Federica
    Marcheix, Bertrand
    Amrane, Hafid
    Bushnaq, Hasan
    Tan, M. Erwin S. H.
    Trivedi, Uday
    Branny, Piotr
    Klugmann, Silvio
    Coletti, Giuseppe
    Dumonteil, Nicolas
    Porta, Fabiano
    Nordell, Anna
    Moat, Neil
    ANNALS OF THORACIC SURGERY, 2017, 103 (05) : 1434 - 1442
  • [28] Transapical transcatheter aortic valve implantation: Follow-up to 3 years
    Ye, Jian
    Cheung, Anson
    Lichtenstein, Samuel V.
    Nietlispach, Fabian
    Albugami, Saad
    Masson, Jean-Bernard
    Thompson, Christopher R.
    Munt, Brad
    Moss, Robert
    Carere, Ronald G.
    Jamieson, W. R. Eric
    Webb, John G.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 139 (05) : 1107 - U27
  • [29] Conduction recovery and avoidance of permanent pacing after transcatheter aortic valve implantation
    Marzahn, Corinne
    Koban, Cornel
    Seifert, Martin
    Isotani, Akihiro
    Neuss, Michael
    Hoeschermann, Frank
    Butter, Christian
    JOURNAL OF CARDIOLOGY, 2018, 71 (1-2) : 101 - 108
  • [30] Transapical transcatheter aortic valve implantation using the J-Valve system: A 1-year follow-up study
    Luo, Xiang
    Wang, Xu
    Li, Xuan
    Wang, Xin
    Xu, Fei
    Liu, Mingzheng
    Yu, Bing
    Li, Fei
    Tong, Minghui
    Wang, Wei
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2017, 154 (01) : 46 - 55