One-year follow-up of conduction disturbances following transcatheter aortic valve implantation

被引:9
|
作者
Salizzoni, Stefano [1 ]
Anselmino, Matteo [2 ]
Fornengo, Cristina [2 ]
Giordana, Francesca [2 ]
La Torre, Michele [1 ]
Moretti, Claudio [2 ]
D'Amico, Maurizio [3 ]
Omede, Pierluigi [2 ]
Marra, Sebastiano [3 ]
Rinaldi, Mauro [1 ]
Gaita, Fiorenzo [2 ]
机构
[1] Univ Turin, Dept Surg Sci, Div Cardiac Surg, Turin, Italy
[2] Univ Turin, Dept Med Sci, Div Cardiol, Turin, Italy
[3] Citta Salute & Sci Hosp, Div Cardiol, Turin, Italy
关键词
aortic stenosis; complications; conduction disturbances; follow-up; pacemaker; transcatheter aortic valve implantation; BUNDLE-BRANCH BLOCK; ATRIOVENTRICULAR-BLOCK; MEDTRONIC COREVALVE; PERMANENT PACEMAKER; HEART-BLOCK; REPLACEMENT; PREDICTORS; STENOSIS; SYSTEM; ABNORMALITIES;
D O I
10.2459/JCM.0000000000000179
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
AimsTo describe the postprocedural and 1-year follow-up incidence of heart conduction disturbances in patients with severe symptomatic aortic stenosis undergoing transcatheter aortic valve implantation (TAVI).MethodsNinety-five patients were enrolled from 2008 to 2011 (mean age 81.87.2 years, 63.1% women). Clinical and ECG data were recorded at admission, discharge, and 3, 6 and 12 months following TAVI.ResultsFifty-seven Edwards SAPIEN (31 transapical, 26 transfemoral) and 38 transfemoral CoreValve implants were used. Two (2.1%) patients died during the procedure and 11 (11.6%) patients received a pacemaker prior to discharge (7 CoreValve, 3 transapical, 1 transfemoral SAPIEN; P=0.18). Among the surviving patients not receiving a pacemaker, TAVI increased the PQ interval (176 +/- 29 vs. 188 +/- 36 ms; P=0.001), QRS width (90 +/- 15 vs. 108 +/- 26 ms; P<0.001), and first-grade atrioventricular block (17 vs. 29%; P<0.001). Postprocedural complete left bundle branch block was reported most in transapical (from 10 to 36%; P=0.01) and CoreValve (from 8 to 64%; P<0.001) recipients compared to the transfemoral SAPIEN group. At the 12-month follow-up, 24 (25.3%) patients had died [two (2.1%) sudden deaths] and four (4.2%) required pacemaker implantation. Among the survivors not receiving a pacemaker at the 1-year follow-up, the PQ interval (178 +/- 27 vs. 188 +/- 36ms; P=0.39) remained unchanged in the ECG, whereas the QRS width (100 +/- 22 vs. 108 +/- 26 ms; P=0.008) decreased compared to measurements taken at discharge.ConclusionConduction disturbances following TAVI primarily develop during hospitalization and subsequently stabilize. However, the small percentage of patients suffering sudden death or pacemaker implantation requires attention.
引用
收藏
页码:296 / 302
页数:7
相关论文
共 50 条
  • [11] Left Ventricular Remodeling After Transcatheter Aortic Valve Implantation One-Year Follow-up Study
    Zakkar, Mustafa
    Alassar, Aiman
    Lopez-Perez, Manuel
    Roy, David
    Brecker, Stephen
    Sharma, Rajan
    Jahangiri, Marjan
    INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2015, 10 (01) : 44 - 47
  • [12] Atrioventricular Conduction After Transcatheter Aortic Valve Implantation and Surgical Aortic Valve Replacement
    Roten, Laurent
    Stortecky, Stefan
    Scarcia, Flavio
    Kadner, Alexander
    Tanner, Hildegard
    Delacretaz, Etienne
    Meier, Bernhard
    Windecker, Stephan
    Carrel, Thierry
    Wenaweser, Peter
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2012, 23 (10) : 1115 - 1122
  • [13] Conduction Disturbances and Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement: Predictors and Prevention
    Tsoi, Melissa
    Tandon, Kanul
    Zimetbaum, Peter J.
    Frishman, William H.
    CARDIOLOGY IN REVIEW, 2022, 30 (04) : 179 - 187
  • [14] Epidemiology, evaluation, and management of conduction disturbances after transcatheter aortic valve replacement
    Aymond, Joshua D.
    Benn, Francis
    Williams, Cody M.
    Bernard, Michael L.
    Hiltbold, A. Elise
    Khatib, Sammy
    Polin, Glenn M.
    Rogers, Paul A.
    Soto, Jose D. Tafur
    Ramee, Stephen R.
    Parrino, P. Eugene
    Falterman, Jason B.
    Al-Khatib, Sana M.
    Morin, Daniel P.
    PROGRESS IN CARDIOVASCULAR DISEASES, 2021, 66 : 37 - 45
  • [15] Cardiac rehabilitation and mid-term follow-up after transcatheter aortic valve implantation
    Zanettini, Renzo
    Gatto, Gemma
    Mori, Ileana
    Pozzoni, Maria Beatrice
    Pelenghi, Stefano
    Martinelli, Luigi
    Klugmann, Silvio
    JOURNAL OF GERIATRIC CARDIOLOGY, 2014, 11 (04) : 279 - 285
  • [16] Depth of valve implantation, conduction disturbances and pacemaker implantation with CoreValve and CoreValve Accutrak system for Transcatheter Aortic Valve Implantation, a multi-center study
    Lenders, Guy D.
    Collas, Valerie
    Maria Hernandez, Jose
    Legrand, Victor
    Danenberg, Haim D.
    den Heijer, Peter
    Rodrigus, Inez E.
    Paelinck, Bernard P.
    Vrints, Christiaan J.
    Bosmans, Johan M.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 176 (03) : 771 - 775
  • [17] Conduction disturbances after transcatheter aortic prosthesis implantation: incidence, characteristics and clinical management
    Bugani, Giulia
    Carinci, Valeria
    Barbato, Gaetano
    Nobile, Giampiero
    Pergolini, Francesco
    Leci, Enri
    Pedone, Chiara
    Colletta, Mauro
    Capecchi, Alessandro
    Iannopollo, Gianmarco
    Casella, Gianni
    GIORNALE ITALIANO DI CARDIOLOGIA, 2024, 25 (08) : 567 - 575
  • [18] Conduction abnormalities after transcatheter aortic valve implantation
    Karyofillis, Panagiotis
    Kostopoulou, Anna
    Thomopoulou, Sofia
    Habibi, Martha
    Livanis, Efthimios
    Karavolias, George
    Voudris, Vassilis
    JOURNAL OF GERIATRIC CARDIOLOGY, 2018, 15 (01) : 105 - 112
  • [19] Electrophysiological Evaluation of Atrioventricular Conduction Disturbances in Transcatheter Aortic Valve Implantation With Edwards SAPIEN Prosthesis
    Eksik, Abdurrahman
    Gul, Mehmet
    Uyarel, Huseyin
    Surgit, Ozgur
    Yildirim, Aydin
    Uslu, Nevzat
    Aksu, Huseyin
    Turen, Selahattin
    Uzun, Fazih
    Satilmisoglu, Hulusi
    Erol, Mustafa Kemal
    Bakir, Ihsan
    JOURNAL OF INVASIVE CARDIOLOGY, 2013, 25 (06) : 305 - 309
  • [20] Prosthesis depth and conduction disturbances after last generation balloon-expandable transcatheter aortic valve implantation
    Iacovelli, Fortunato
    Pignatelli, Antonio
    Giugliano, Giuseppe
    Stabile, Eugenio
    Cicala, Mariangela
    Salemme, Luigi
    Cioppa, Angelo
    Popusoi, Grigore
    Pucciarelli, Armando
    Verdoliva, Sebastiano
    Bortone, Alessandro Santo
    Losi, Maria-Angela
    Coscioni, Enrico
    Esposito, Giovanni
    Contegiacomo, Gaetano
    Tesorio, Tullio
    EUROPACE, 2018, 20 (01): : 116 - 123