One-year follow-up of conduction disturbances following transcatheter aortic valve implantation

被引:9
|
作者
Salizzoni, Stefano [1 ]
Anselmino, Matteo [2 ]
Fornengo, Cristina [2 ]
Giordana, Francesca [2 ]
La Torre, Michele [1 ]
Moretti, Claudio [2 ]
D'Amico, Maurizio [3 ]
Omede, Pierluigi [2 ]
Marra, Sebastiano [3 ]
Rinaldi, Mauro [1 ]
Gaita, Fiorenzo [2 ]
机构
[1] Univ Turin, Dept Surg Sci, Div Cardiac Surg, Turin, Italy
[2] Univ Turin, Dept Med Sci, Div Cardiol, Turin, Italy
[3] Citta Salute & Sci Hosp, Div Cardiol, Turin, Italy
关键词
aortic stenosis; complications; conduction disturbances; follow-up; pacemaker; transcatheter aortic valve implantation; BUNDLE-BRANCH BLOCK; ATRIOVENTRICULAR-BLOCK; MEDTRONIC COREVALVE; PERMANENT PACEMAKER; HEART-BLOCK; REPLACEMENT; PREDICTORS; STENOSIS; SYSTEM; ABNORMALITIES;
D O I
10.2459/JCM.0000000000000179
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
AimsTo describe the postprocedural and 1-year follow-up incidence of heart conduction disturbances in patients with severe symptomatic aortic stenosis undergoing transcatheter aortic valve implantation (TAVI).MethodsNinety-five patients were enrolled from 2008 to 2011 (mean age 81.87.2 years, 63.1% women). Clinical and ECG data were recorded at admission, discharge, and 3, 6 and 12 months following TAVI.ResultsFifty-seven Edwards SAPIEN (31 transapical, 26 transfemoral) and 38 transfemoral CoreValve implants were used. Two (2.1%) patients died during the procedure and 11 (11.6%) patients received a pacemaker prior to discharge (7 CoreValve, 3 transapical, 1 transfemoral SAPIEN; P=0.18). Among the surviving patients not receiving a pacemaker, TAVI increased the PQ interval (176 +/- 29 vs. 188 +/- 36 ms; P=0.001), QRS width (90 +/- 15 vs. 108 +/- 26 ms; P<0.001), and first-grade atrioventricular block (17 vs. 29%; P<0.001). Postprocedural complete left bundle branch block was reported most in transapical (from 10 to 36%; P=0.01) and CoreValve (from 8 to 64%; P<0.001) recipients compared to the transfemoral SAPIEN group. At the 12-month follow-up, 24 (25.3%) patients had died [two (2.1%) sudden deaths] and four (4.2%) required pacemaker implantation. Among the survivors not receiving a pacemaker at the 1-year follow-up, the PQ interval (178 +/- 27 vs. 188 +/- 36ms; P=0.39) remained unchanged in the ECG, whereas the QRS width (100 +/- 22 vs. 108 +/- 26 ms; P=0.008) decreased compared to measurements taken at discharge.ConclusionConduction disturbances following TAVI primarily develop during hospitalization and subsequently stabilize. However, the small percentage of patients suffering sudden death or pacemaker implantation requires attention.
引用
收藏
页码:296 / 302
页数:7
相关论文
共 50 条
  • [1] One-Year Follow-Up of Conduction Abnormalities After Transcatheter Aortic Valve Implantation With the SAPIEN 3 Valve
    Dolci, Giulia
    Vollema, E. Mara
    van der Kley, Frank
    de Weger, Arend
    Marsan, Nina Ajmone
    Delgado, Victoria
    Bax, Jeroen J.
    AMERICAN JOURNAL OF CARDIOLOGY, 2019, 124 (08) : 1239 - 1245
  • [2] Understanding experiences of undergoing transcatheter aortic valve implantation: one-year follow-up
    Baumbusch, Jennifer
    Lauck, Sandra B.
    Achtem, Leslie
    O'Shea, Tamar
    Wu, Sarah
    Banner, Davina
    EUROPEAN JOURNAL OF CARDIOVASCULAR NURSING, 2018, 17 (03) : 280 - 288
  • [3] Occurrence and Persistency of Conduction Disturbances during Transcatheter Aortic Valve Implantation
    Poels, Thomas T.
    Engels, Elien B.
    Kats, Suzanne
    Veenstra, Leo
    van Ommen, Vincent
    Vernooy, Kevin
    Maessen, Jos G.
    Prinzen, Frits W.
    MEDICINA-LITHUANIA, 2021, 57 (07):
  • [4] Conduction disturbances after transcatheter aortic valve implantation procedures - predictors and management
    Wilczek, Krzysztof
    Regula, Rafal
    Bujak, Kamil
    Chodor, Piotr
    Dlugaszek, Michal
    Gasior, Mariusz
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2016, 12 (03): : 203 - 211
  • [5] Transapical Transcatheter Aortic Valve Implantation Using the JenaValve: A One-Year Follow-up
    Reuthebuch, Oliver
    Koechlin, Luca
    Kaufmann, Beat A.
    Kessel-Schaefer, Arnheid
    Gahl, Brigitta
    Eckstein, Friedrich S.
    THORACIC AND CARDIOVASCULAR SURGEON, 2015, 63 (06) : 493 - 500
  • [6] Transcatheter Aortic Valve Implantation and Conduction Disturbances: Focus on Clinical Implications
    Halapas, Antonios
    Koliastasis, Leonidas
    Doundoulakis, Ioannis
    Antoniou, Christos-Konstantinos
    Stefanadis, Christodoulos
    Tsiachris, Dimitrios
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2023, 10 (11)
  • [7] Conduction disorders in the setting of transcatheter aortic valve implantation: a clinical perspective
    Fraccaro, Chiara
    Napodano, Massimo
    Tarantini, Giuseppe
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (07) : 1217 - 1223
  • [8] Pathophysiology, incidence and predictors of conduction disturbances during Transcatheter Aortic Valve Implantation
    Barbanti, Marco
    Gulino, Simona
    Costa, Giuliano
    Tamburino, Corrado
    EXPERT REVIEW OF MEDICAL DEVICES, 2017, 14 (02) : 135 - 147
  • [9] Percutaneous transcatheter aortic valve implantation for degenerated surgical bioprostheses: the first case series in Asia with one-year follow-up
    Chiam, Paul Toon Lim
    Ewe, See Hooi
    Soon, Jia Lin
    Ho, Kay Woon
    Sin, Yong Koong
    Tan, Swee Yaw
    Lim, Soo Teik
    Koh, Tian Hai
    Chua, Yeow Leng
    SINGAPORE MEDICAL JOURNAL, 2016, 57 (07) : 401 - 405
  • [10] Perioperative Conduction Disturbances After Transcatheter Aortic Valve Replacement
    Ghadimi, Kamrouz
    Patel, Prakash A.
    Gutsche, Jacob T.
    Sophocles, Aris
    Anwaruddin, Saif
    Szeto, Wilson Y.
    Augoustides, John G. T.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2013, 27 (06) : 1414 - 1420