A simplified method to evaluate the flexural capacity of lightweight cold-formed steel floor system with oriented strand board subfloor

被引:34
作者
Zhou, Xuhong [1 ,2 ]
Shi, Yu [1 ,2 ]
Xu, Lei [1 ,3 ]
Yao, Xinmei [4 ]
Wang, Weiyong [1 ,2 ]
机构
[1] Chongqing Univ, Coll Civil Engn, Chongqing 400045, Peoples R China
[2] Chongqing Univ, Key Lab New Technol Construct Cities Mt Area, Minist Educ, Chongqing 400045, Peoples R China
[3] Univ Waterloo, Dept Civil & Environm Engn, Waterloo, ON N2L 3G1, Canada
[4] Changan Univ, Coll Civil Engn, Xian 710061, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Cold-formed steel; Floor system; Flexural capacity; Experimental investigation; Simplified method; VIBRATION;
D O I
10.1016/j.tws.2018.09.006
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Lightweight floors built with cold-formed steel C-shape joists and oriented strand board sheathing is one of the primary floor systems in cold-formed steel residential construction. In order to investigate the flexural capacity with accounting for the composite action of the floor system, two tests on the flexural capacity of the floor system were carried out. The test results indicated that the load-carrying capacity of the floor system was significantly affected by the spacing of the screws that connect the joist and oriented strand board sheathing. The primary failure mode of the floor system was the local buckling at the critical section of the C-shape joist although there was tendency of lateral-torsion buckling of the joist. The wavelength of the buckling mode was approximately equal to the screw spacing. A finite element mode was established to simulate the structural behaviour of the floors by commercial software ANSYS and it was found that the numerical results agreed well with the test data. Parametric studies were carried out based on numerical analysis to investigate how the flexural capacity of the floors was influenced by different factors such as screw spacing, joist spacing and sheathing thickness, etc. Finally, based on the test data and numerical analysis results, a simplified design method was proposed to predict the flexural capacity of the floors with accounting for the composite action. The results obtained from the proposed method were validated by both experimental and numerical investigations of two full-scale lightweight floors built with cold-formed steel C-shape joist and oriented strand board subfloor.
引用
收藏
页码:40 / 51
页数:12
相关论文
共 21 条
[1]  
AISI, 2012, S20112 AISI
[2]  
AISI, 2017, RP172 AISI
[3]  
AISI (American Iron and Steel Institute), 2015, Standard for cold-formed steel framing-prescriptive method for one and two family dwellings
[4]  
AISI (American Iron and Steel Institute), 2013, Method for flexural testing of cold-formed steel hat- shaped beams
[5]  
*ANS INC, 2009, EL REF
[6]  
Ansys, 2009, Knowledge Creation Diffusion Utilization, V3304, P724
[7]   Predicting rotational restraint provided to wall girts and roof purlins by through-fastened metal panels [J].
Gao, Tian ;
Moen, Cristopher D. .
THIN-WALLED STRUCTURES, 2012, 61 :145-153
[8]  
GAQSIQ and SAC, 2011, 22812010 GBT GAQSIQ
[9]   New composite beams having cold-formed steel joists and concrete slab [J].
Hsu, Cheng-Tzu Thomas ;
Punurai, Sun ;
Punurai, Wonsiri ;
Majdi, Yazdan .
ENGINEERING STRUCTURES, 2014, 71 :187-200
[10]  
Kankanamge N. D., 2012, THIN WALLED STRUCT, V51