Hybrid coagulation-NF membrane process for brackish water treatment: Effect of antiscalant on water characteristics and membrane fouling

被引:39
作者
Ang, W. L. [1 ]
Mohammad, A. W. [1 ,2 ]
Benamor, A. [3 ]
Hilal, N. [4 ]
Leo, C. P. [5 ]
机构
[1] Univ Kebangsaan Malaysia, Dept Chem & Proc Engn, Fac Engn & Built Environm, Bangi 43600, Selangor Darul, Malaysia
[2] Univ Kebangsaan Malaysia, Ctr Sustainable Proc Technol CESPRO, Fac Engn & Built Environm, Bangi 43600, Selangor Darul, Malaysia
[3] Qatar Univ, Gas Proc Ctr, Doha, Qatar
[4] Swansea Univ, CWATER, Coll Engn, Swansea SA2 8PP, W Glam, Wales
[5] Univ Sains Malaysia, Sch Chem Engn, Engn Campus, Nibong Tebal 14300, Pulau Pinang, Malaysia
关键词
Hybrid coagulation-membrane process; Antiscalants; Scaling; Membrane fouling; Brackish water desalination; Water treatment; SCALE CONTROL ADDITIVES; NATURAL ORGANIC-MATTER; REVERSE-OSMOSIS; SEAWATER DESALINATION; RESIDUAL ALUMINUM; RECYCLE BRINE; PERFORMANCE; INHIBITION; RO; NANOFILTRATION;
D O I
10.1016/j.desal.2016.01.010
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Antiscalants have been used to inhibit the formation of scales and reduce the risk of membrane scaling. However, issues such as the increased of biofouling tendency and contradictory observations of organic fouling propensity under the influence of antiscalants have been reported by other researchers. Such observations indicate the need for thorough understanding about the interaction between antiscalants and membrane/foulants in the solution. This study investigated the influence of antiscalant on the water characteristics and the performance of hybrid coagulation-nanofiltration membrane process for brackish water treatment. It was observed that scaling was mitigated with the addition of antiscalants but membrane fouling was exacerbated at higher dosage, probably due to the changes in foulant properties induced by antiscalants. Analysis carried out on the water showed that antiscalants altered the characteristics of the foulants and formed precipitates with calcium/aluminum and iron (from coagulant) ions, which eventually deposited as foulant layer on the membrane surface. This was proven with the existence of phosphorous element on the membrane surface using SEM-EDX. The findings demonstrated how the antiscalants altered the water characteristics and provided insight into the reactivity of antiscalants present in different concentrations, which could be used to interpret the contradicting findings from other researchers. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:144 / 150
页数:7
相关论文
共 32 条
[1]   Fouling strategies and the cleaning system of NF membranes and factors affecting cleaning efficiency [J].
Al-Amoudi, Ahmed ;
Lovitt, Robert W. .
JOURNAL OF MEMBRANE SCIENCE, 2007, 303 (1-2) :6-28
[2]   Hybrid chitosan/FeCl3 coagulation-membrane processes: Performance evaluation and membrane fouling study in removing natural organic matter [J].
Ang, W. L. ;
Mohammad, A. W. ;
Teow, Y. H. ;
Benamor, A. ;
Hilal, N. .
SEPARATION AND PURIFICATION TECHNOLOGY, 2015, 152 :23-31
[3]  
Ang W.L., HYBRID COAGULATION N
[4]   A review on the applicability of integrated/hybrid membrane processes in water treatment and desalination plants [J].
Ang, Wei Lun ;
Mohammad, Abdul Wahab ;
Hilal, Nidal ;
Leo, Choe Peng .
DESALINATION, 2015, 363 :2-18
[5]   Modified pectin-based polymers as green antiscalants for calcium sulfate scale inhibition [J].
Chauhan, Kalpana ;
Kumar, Rajeev ;
Kumar, Muneesh ;
Sharma, Praveen ;
Chauhan, Ghanshyam S. .
DESALINATION, 2012, 305 :31-37
[6]   The safe use of cationic flocculants with reverse osmosis membranes [J].
Chesters, S. P. ;
Darton, E. G. ;
Gallego, Silvia ;
Vigo, F. D. .
DESALINATION AND WATER TREATMENT, 2009, 6 (1-3) :144-151
[7]   Innovations in the inhibition and cleaning of reverse osmosis membrane scaling and fouling [J].
Chesters, Stephen P. .
DESALINATION, 2009, 238 (1-3) :22-29
[8]   Effect of various forms of iron in recycle brine on performance of scale control additives in MSF desalination plants [J].
Dalvi, AGI ;
Mohammad, MNK ;
Al-Sulami, S ;
Sahul, K ;
Al-Rasheed, R .
DESALINATION, 1999, 123 (2-3) :177-184
[9]   Role of chemical constituents in recycle brine on the performance of scale control additives in MSF plants [J].
Dalvi, AGI ;
Mohammad, NMK ;
Al-Sulami, S ;
Sahul, K ;
Al-Rasheed, R .
DESALINATION, 2000, 129 (02) :173-186
[10]  
Dayton E.G., 2000, DESALINATION, V132, P121