High-Pitch 128-Slice Dual-Source CT for the Assessment of Coronary Stents in a Phantom Model

被引:16
作者
Donati, Olivio F. [1 ]
Burg, Matthias C. [2 ]
Desbiolles, Lotus [1 ]
Karlo, Christoph [1 ]
Stolzmann, Paul [1 ,3 ]
Bunck, Alexander [2 ]
Baumueller, Stephan [1 ]
Marincek, Borut [1 ]
Seifarth, Harald [2 ]
Alkadhi, Hatem [1 ,3 ]
Leschka, Sebastian [1 ]
Maintz, David [2 ]
机构
[1] Univ Zurich Hosp, Inst Diagnost Radiol, CH-8091 Zurich, Switzerland
[2] Univ Munster, Dept Clin Radiol, D-4400 Munster, Germany
[3] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Cardiac MR PET CT Program, Boston, MA USA
关键词
Stent; computed tomography; high pitch; coronary artery disease; dual source; PACLITAXEL-ELUTING STENT; IN-VITRO EVALUATION; BARE-METAL STENT; COMPUTED-TOMOGRAPHY; ANGIOGRAPHY; PATENCY; RESTENOSIS;
D O I
10.1016/j.acra.2010.06.017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: To evaluate the quality of stent lumen delineation using dual-source computed tomography (DSCT) in the standard-pitch mode (SP) as compared to the high-pitch mode (HP) in a phantom study. Materials and Methods: Forty different coronary stents placed in plastic tubes filled with contrast agent were imaged with a second generation DSCT system in a SP (pitch 0.23) and HP (pitch 3.4) mode in orientations of 0, 450, and 90 relative to the z-axis. Two observers independently measured the in-stent lumen and the attenuation values in the center of the stents. The artificial lumen narrowing (ALN) was calculated using the measured in-stent lumen and the nominal diameter of the plastic tube. Results: lnterobserver correlation was excellent for in-stent lumen (0.86) and attenuation measurements (0.91). There was no significant difference neither for ALN (SP: 54.7-62.8%; HP: 55.8-64.0%) nor attenuation (SP: 356-395 Hounsfield units [HU]; HP: 352-384 HU) between SP and HP mode. For both modes, the orientation of the stent relative to the z-axis significantly affected ALN and attenuation (each P < .001). CT volume dose index was significantly lower using HP mode as compared to SP mode (P < .001). Conclusion: The HP mode in DSCT provides visualization of the coronary in-stent lumen comparable to that measured in SP mode while reducing applied radiation dose in a stationary phantom model.
引用
收藏
页码:1366 / 1374
页数:9
相关论文
共 21 条
[1]   Influence of slice thickness and reconstruction kernel on the computed tomographic attenuation of coronary atherosclerotic plaque [J].
Achenbach, Stephan ;
Boehmer, Kerstin ;
Pflederer, Tobias ;
Ropers, Dieter ;
Seltmann, Martin ;
Lell, Michael ;
Anders, Katharina ;
Kuettner, Axel ;
Uder, Michael ;
Daniel, Werner G. ;
Marwan, Mohamed .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2010, 4 (02) :110-115
[2]   Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition [J].
Achenbach, Stephan ;
Marwan, Mohamed ;
Ropers, Dieter ;
Schepis, Tiziano ;
Pflederer, Tobias ;
Anders, Katharina ;
Kuettner, Axel ;
Daniel, Werner G. ;
Uder, Michael ;
Lell, Michael M. .
EUROPEAN HEART JOURNAL, 2010, 31 (03) :340-346
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Contrast-enhanced 64-section coronary multidetector CT angiography versus conventional coronary angiography for Stent assessment [J].
Das, K. M. ;
El-Menyar, Ayman A. ;
Salam, Amar M. ;
Singh, Rajvir ;
Dabdoob, Wafer Amin K. ;
Albinali, Hajar A. ;
Al Suwaidi, Jassim .
RADIOLOGY, 2007, 245 (02) :424-432
[5]  
Haraldsdottir S, 2009, EUR J RADIOL 0629
[6]   Accuracy of MSCT coronary angiography with 64-slice technology:: first experience [J].
Leschka, S ;
Alkadhi, H ;
Plass, A ;
Desbiolles, L ;
Grünenfelder, J ;
Marincek, B ;
Wildermuth, S .
EUROPEAN HEART JOURNAL, 2005, 26 (15) :1482-1487
[7]   Diagnostic accuracy of high-pitch dual-source CT for the assessment of coronary stenoses: first experience [J].
Leschka, Sebastian ;
Stolzmann, Paul ;
Desbiolles, Lotus ;
Baumueller, Stephan ;
Goetti, Robert ;
Schertler, Thomas ;
Scheffel, Hans ;
Plass, Andre ;
Falk, Volkmar ;
Feuchtner, Gudrun ;
Marincek, Borut ;
Alkadhi, Hatem .
EUROPEAN RADIOLOGY, 2009, 19 (12) :2896-2903
[8]   Heart Disease and Stroke Statistics-2009 Update A Report From the American Heart Association Statistics Committee and Stroke Statistics Subcommittee [J].
Lloyd-Jones, Donald ;
Adams, Robert ;
Carnethon, Mercedes ;
De Simone, Giovanni ;
Ferguson, T. Bruce ;
Flegal, Katherine ;
Ford, Earl ;
Furie, Karen ;
Go, Alan ;
Greenlund, Kurt ;
Haase, Nancy ;
Hailpern, Susan ;
Ho, Michael ;
Howard, Virginia ;
Kissela, Brett ;
Kittner, Steven ;
Lackland, Daniel ;
Lisabeth, Lynda ;
Marelli, Ariane ;
McDermott, Mary ;
Meigs, James ;
Mozaffarian, Dariush ;
Nichol, Graham ;
O'Donnell, Christopher ;
Roger, Veronique ;
Rosamond, Wayne ;
Sacco, Ralph ;
Sorlie, Paul ;
Stafford, Randall ;
Steinberger, Julia ;
Thom, Thomas ;
Wasserthiel-Smoller, Sylvia ;
Wong, Nathan ;
Wylie-Rosett, Judith ;
Hong, Yuling .
CIRCULATION, 2009, 119 (03) :E21-E181
[9]   64-slice multidetector coronary CT angiography:: in vitro evaluation of 68 different stents [J].
Maintz, D ;
Seifarth, H ;
Raupach, R ;
Flohr, T ;
Rink, M ;
Sommer, T ;
Özgün, M ;
Heindel, W ;
Fischbach, R .
EUROPEAN RADIOLOGY, 2006, 16 (04) :818-826
[10]   Update on multidetector coronary CT angiography of coronary stents: in vitro evaluation of 29 different stent types with dual-source CT [J].
Maintz, David ;
Burg, Matthias C. ;
Seifarth, Harald ;
Bunck, Alexander C. ;
Oezguen, Murat ;
Fischbach, Roman ;
Juergens, Kai Uwe ;
Heindel, Walter .
EUROPEAN RADIOLOGY, 2009, 19 (01) :42-49