Value of Left Atrial Appendage Function Measured by Transesophageal Echocardiography for Prediction of Atrial Fibrillation Recurrence after Radiofrequency Catheter Ablation

被引:19
|
作者
Istratoaie, Sabina [1 ]
Vesa, Stefan C. [1 ]
Cismaru, Gabriel [2 ]
Pop, Dana [2 ]
Rosu, Radu [2 ]
Puiu, Mihai [2 ]
Pepine, Diana [2 ]
Ciobanu, Cristina [2 ]
Minciuna, Ioan A. [2 ]
Simu, Gelu [2 ]
Zdrenghea, Dumitru [2 ]
Buzoianu, Anca D. [1 ]
机构
[1] Iuliu Hatieganu Univ Med & Pharm, Dept Pharmacol Toxicol & Clin Pharmacol, Cluj Napoca 400337, Romania
[2] Iuliu Hatieganu Univ Med & Pharm, Dept Internal Med 5, Cardiol Rehabil, Cluj Napoca 400066, Romania
关键词
atrial fibrillation; transesophageal echocardiography; left atrial appendage emptying flow velocity; PULMONARY VEIN ISOLATION; FLOW VELOCITY; FOLLOW-UP; ASSOCIATION; VOLUME; SIZE;
D O I
10.3390/diagnostics11081465
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Atrial fibrillation (AF) recurrence after radiofrequency catheter ablation (RFCA) remains a challenging issue. This study aims to explore the left atrial appendage function by transesophageal echocardiography (TEE) and assess its value in predicting AF recurrence following RFCA in paroxysmal AF patients. Eighty-one patients with paroxysmal AF that underwent RFCA were recruited. TEE was performed before ablation with the assessment of left atrial appendage emptying flow velocity (LAAeV). AF recurrence occurred in 24 patients (29.6%) within 12 months after RFCA. The left atrium diameter (LAD) and left atrium volume index (LAVI) were both significantly higher in the recurrence group compared to the non-recurrence group, while the LAAeV was significantly lower in the recurrence group. LAD, LAVi and LAAeV were univariately significant risk factors for AF recurrence after ablation. Based on receiver operating curve (ROC), LAAeV < 40.5 cm/s, LAVi > 40.5 mL and LAD > 41 mm were identified as cut-off values for predicting AF recurrence. In multivariate regression analysis LAAeV < 40.5 cm/s (HR 8.194, 95% CI 2.980-22.530, p < 0.001) was identified as the only statistically significant independent predictor of AF recurrence, as the statistical significance threshold was not achieved for LAVI > 40.5 mL and LAD > 41 mm (p = 0.319; p = 0.507, respectively). A low LAAeV was the only important independent predictor of AF recurrence within 1 year after first RFCA.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Risk stratification of patients with left atrial appendage thrombus prior to catheter ablation of atrial fibrillation: An approach towards an individualized use of transesophageal echocardiography
    Gunawardene, Melanie A.
    Dickow, Jannis
    Schaeffer, Benjamin N.
    Akbulak, Ruken Oe
    Lemoine, Marc D.
    Nuehrich, Jana M.
    Jularic, Mario
    Sinning, Christoph
    Eickholt, Christian
    Meyer, Christian
    Moser, Julia M.
    Hoffmann, Boris A.
    Willems, Stephan
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2017, 28 (10) : 1127 - 1136
  • [22] Prediction of improvement in left atrial function index after catheter ablation for atrial fibrillation
    Nagase, Takahiko
    Kato, Ritsushi
    Nakano, Shintaro
    Shiki, Yuichirou
    Tanaka, Sayaka
    Ikeda, Yoshifumi
    Iwanaga, Shiro
    Nishimura, Shigeyuki
    Matsumoto, Kazuo
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2015, 44 (02) : 151 - 160
  • [23] Left atrial appendage orifice dimensions in Japanese atrial fibrillation population measured by multiplane transesophageal echocardiography
    Miho Miyoshi
    Nozomi Watanabe
    Tomoko Fukuda
    Shun Nishino
    Toshiyuki Kimura
    Makoto Furugen
    Keiichi Ashikaga
    Naohiko Takahashi
    Yoshisato Shibata
    Journal of Echocardiography, 2022, 20 : 201 - 207
  • [24] Association of Left Atrial Function IndexWith Late Atrial Fibrillation Recurrence after Catheter Ablation
    Sardana, Mayank
    Ogunsua, Adedotun A.
    Spring, Matthew
    Shaikh, Amir
    Asamoah, Owusu
    Stokken, Glenn
    Browning, Clifford
    Ennis, Cynthia
    Donahue, J. Kevin
    Rosenthal, Lawrence S.
    Floyd, Kevin C.
    Aurigemma, Gerard P.
    Parikh, Nisha I.
    Mcmanus, David D.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2016, 27 (12) : 1411 - 1419
  • [25] Low left atrial appendage emptying velocity is a predictor of atrial fibrillation recurrence after catheter ablation
    Thotamgari, Sahith Reddy
    Sheth, Aakash Rajendra
    Ahmad, Javaria
    Bawa, Danish
    Thevuthasan, Sindhu
    Babbili, Akhilesh
    Bhuiyan, Mohammad Alfrad Nobel
    Brar, Vijaywant
    Duddyala, Narendra
    Amorn, Allen
    Dominic, Paari
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2022, 33 (08) : 1705 - 1711
  • [26] Value of cystatin C in predicting atrial fibrillation recurrence after radiofrequency catheter ablation
    Jin, Li-Li
    You, Ling
    Xie, Rui-Qin
    JOURNAL OF GERIATRIC CARDIOLOGY, 2018, 15 (12) : 725 - 731
  • [27] Low left atrial appendage flow velocity predicts recurrence of atrial fibrillation after catheter ablation of persistent atrial fibrillation
    Kanda, Takashi
    Masuda, Masaharu
    Sunaga, Akihiro
    Fujita, Masashi
    Iida, Osamu
    Okamoto, Shin
    Ishihara, Takayuki
    Watanabe, Tetsuya
    Takahara, Mitsuyoshi
    Sakata, Yasushi
    Uematsu, Masaaki
    JOURNAL OF CARDIOLOGY, 2015, 66 (5-6) : 377 - 381
  • [28] Blood flow volume of left atrial appendage measured by magnetic resonance imaging is improved after radiofrequency catheter ablation of atrial fibrillation
    Kim, Yun Gi
    Min, Kyongjin
    Hwang, Sung Ho
    Shim, Jaemin
    Choi, Yun Young
    Choi, Ha Young
    Choi, Jong-Il
    Oh, Yu-Whan
    Kim, Young-Hoon
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (03) : 669 - 677
  • [29] Morphological changes of the left atrial appendage after catheter ablation of atrial fibrillation
    Chang, Sheng-Hsiung
    Tsao, Hsuan-Ming
    Wu, Mei-Han
    Tai, Ching-Tai
    Chang, Shih-Lin
    Wongcharoen, Wanwarang
    Lin, Yenn-Jiang
    Lo, Li-Wei
    Hsieh, Ming-Hsiung
    Sheu, Ming-Huei
    Chang, Cheng-Yen
    Jia-Yin, Charles
    Chen, Shih-Ann
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2007, 18 (01) : 47 - 52
  • [30] Echocardiography evaluation of iatrogenic atrial septal defect after combined procedure of catheter ablation and left atrial appendage closure for atrial fibrillation
    Su, Yu Xin
    Li, Sai Nan
    Liu, Nan Nan
    Liang, Ming
    Wang, Zu Lu
    Zhang, Ping
    Zhang, Qi
    Zhou, Wei Wei
    SCIENTIFIC REPORTS, 2025, 15 (01):