Elucidation of artefacts in proton transfer reaction time-of-flight mass spectrometers

被引:7
|
作者
Salazar Gomez, Jorge Ivan [1 ]
Klucken, Christian [1 ]
Sojka, Martha [1 ]
Masliuk, Liudmyla [2 ]
Lunkenbein, Thomas [2 ]
Schloegl, Robert [1 ,2 ]
Ruland, Holger [1 ]
机构
[1] Max Planck Inst Chem Energy Convers, Dept Heterogeneous React, Stiftstr 34-36, D-45470 Mulheim, Germany
[2] Fritz Haber Inst Max Planck Soc, Dept Inorgan Chem, Berlin, Germany
来源
JOURNAL OF MASS SPECTROMETRY | 2019年 / 54卷 / 12期
关键词
artefacts; industrial gases; parasitic ions; proton transfer reaction time-of-flight mass spectrometry; volatile organic compounds; VOLATILE ORGANIC-COMPOUNDS; COKE-OVEN GAS; PTR-MS; UMIST DATABASE; IONS; H3O+; VALIDATION; INSTRUMENT; MOLECULES; O-2(+);
D O I
10.1002/jms.4479
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We present an effective procedure to differentiate instrumental artefacts, such as parasitic ions, memory effects, and real trace impurities contained in inert gases. Three different proton transfer reaction mass spectrometers were used in order to identify instrument-specific parasitic ions. The methodology reveals new nitrogen- and metal-containing ions that up to date have not been reported. The parasitic ion signal was dominated by [N-2]H+ and [NH3]H+ rather than by the common ions NO+ and O-2(+). Under dry conditions in a proton transfer reaction quadrupole interface time-of-flight mass spectrometer (PTR-QiTOF), the ion abundances of [N-2]H+ were elevated compared with the signals in the presence of humidity. In contrast, the [NH3]H+ ion did not show a clear humidity dependency. On the other hand, two PTR-TOF1000 instruments showed no significant contribution of the [N-2]H+ ion, which supports the idea of [N-2]H+ formation in the quadrupole interface of the PTR-QiTOF. Many new nitrogen-containing ions were identified, and three different reaction sequences showing a similar reaction mechanism were established. Additionally, several metal-containing ions, their oxides, and hydroxides were formed in the three PTR instruments. However, their relative ion abundancies were below 0.03% in all cases. Within the series of metal-containing ions, the highest contribution under dry conditions was assigned to the [Fe(OH)(2)]H+ ion. Only in one PTR-TOF1000 the Fe+ ion appeared as dominant species compared with the [Fe(OH)(2)]H+ ion. The present analysis and the resulting database can be used as a tool for the elucidation of artefacts in mass spectra and, especially in cases, where dilution with inert gases play a significant role, preventing misinterpretations.
引用
收藏
页码:987 / 1002
页数:16
相关论文
共 50 条
  • [21] Detection of gaseous dimethylamine using vocus proton-transfer-reaction time-of-flight mass spectrometry
    Wang, Yuwei
    Yang, Gan
    Lu, Yiqun
    Liu, Yiliang
    Chen, Jianmin
    Wang, Lin
    ATMOSPHERIC ENVIRONMENT, 2020, 243
  • [22] Complexity of downy birch emissions revealed by Vocus proton transfer reaction time-of-flight mass spectrometer
    Thomas, Steven Job
    Li, Haiyan
    Praplan, Arnaud R.
    Hellen, Heidi
    Bianchi, Federico
    FRONTIERS IN FORESTS AND GLOBAL CHANGE, 2022, 5
  • [23] Operando proton-transfer-reaction time-of-flight mass spectrometry of carbon dioxide reduction electrocatalysis
    Hangjuan Ren
    Mikhail Kovalev
    Zhaoyue Weng
    Marsha Zakir Muhamad
    Hongyang Ma
    Yuan Sheng
    Libo Sun
    Jingjing Wang
    Simon Rihm
    Wanfeng Yang
    Alexei A. Lapkin
    Joel W. Ager
    Nature Catalysis, 2022, 5 : 1169 - 1179
  • [24] Operando proton-transfer-reaction time-of-flight mass spectrometry of carbon dioxide reduction electrocatalysis
    Ren, Hangjuan
    Kovalev, Mikhail
    Weng, Zhaoyue
    Muhamad, Marsha Zakir
    Ma, Hongyang
    Sheng, Yuan
    Sun, Libo
    Wang, Jingjing
    Rihm, Simon
    Yang, Wanfeng
    Lapkin, Alexei A.
    Ager, Joel W.
    NATURE CATALYSIS, 2022, 5 (12) : 1169 - 1179
  • [25] Rapid and direct identification of the origin of white tea with proton transfer reaction time-of-flight mass spectrometry
    Zhang, Dandan
    Wu, Weihua
    Qiu, Xiaohong
    Li, Xiaojing
    Zhao, Feng
    Ye, Naixing
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2020, 34 (20)
  • [26] NEUTRON TIME-OF-FLIGHT SPECTROMETERS
    FIRK, FWK
    NUCLEAR INSTRUMENTS & METHODS, 1979, 162 (1-3): : 539 - 563
  • [27] Ion-optical properties of time-of-flight mass spectrometers
    Ioanoviciu, D
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2001, 206 (03) : 211 - 229
  • [28] OSCILLOSCOPE DISPLAY AND ANALOG GATING FOR TIME-OF-FLIGHT MASS SPECTROMETERS
    RIGBY, LJ
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1973, 6 (12): : 1182 - 1183
  • [29] Direct sampling time-of-flight mass spectrometers for technological analysis
    Alexander A. Sysoev
    Alexey A. Sysoev
    S. S. Poteshin
    V. I. Pyatakhin
    I. V. Shchekina
    A. S. Trofimov
    Fresenius' Journal of Analytical Chemistry, 1998, 361 : 261 - 266
  • [30] TIME-OF-FLIGHT MASS SPECTROMETERS WITH MULTIPLY REFLECTED ION TRAJECTORIES