Thermal 3D CFD Simulation with Active Transparent Facade in Buildings

被引:4
作者
Ramirez-Balas, Cristina [1 ]
Fernandez-Nieto, Enrique [2 ]
Narbona-Reina, Gladys [2 ]
Jose Sendra, Juan [1 ]
Suarez, Rafael [1 ]
机构
[1] Univ Seville, Inst Univ Arquitectura & Ciencias Construcc, Escuela Tecn Super Arquitectura, E-41012 Seville, Spain
[2] Univ Seville, Escuela Tecn Super Arquitectura, Dept Matemat Aplicada 1, E-41012 Seville, Spain
关键词
3D numerical modelling; thermal computational fluid dynamics (CFD) simulation; active transparent facade (ATF); double-skin facade (DSF); City of Refuge by Le Corbusier; mur neutralisant; DOUBLE-SKIN FACADE; AIR-FLOW; PERFORMANCE; VENTILATION; BEHAVIOR; MODEL; ROOM;
D O I
10.3390/en11092265
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In recent years active facades have acquired greater importance given their capacity to improve the energy efficiency of buildings. One such type is the so-called Active Transparent Facade (ATF). A 3D numerical model based on computational fluid dynamics (CFD) and the Finite Element Method (FEM) has been generated to simulate the thermal performance of buildings equipped with this type of facade. This model is introduced for general application and allows the design parameters to be adapted for this system. The case study of Le Corbusier's proposal for the City of Refuge in Paris, the clearest example of previous use of an ATF is examined. In addition, a proposal is presented for the energy improvement of Le Corbusier's original solution. In order to do so, the conditions for the supply of air into the ATF cavity and in the mechanical ventilation system are assessed to guarantee comfort conditions.
引用
收藏
页数:19
相关论文
共 33 条
[1]  
[Anonymous], 2005, Ergonomics of the thermal environment _ Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria
[2]   MATRIX, a multi activity test-room for evaluating the energy performances of 'building/HVAC' systems in Mediterranean climate: Experimental set-up and CFD/BPS numerical modeling [J].
Ascione, Fabrizio ;
De Masi, Rosa Francesca ;
de Rossi, Filippo ;
Ruggiero, Silvia ;
Vanoli, Giuseppe Peter .
ENERGY AND BUILDINGS, 2016, 126 :424-446
[3]  
Banham Reyner., 1969, ARCHITECTURE WELL TE
[4]   Perspectives of double skin facades for naturally ventilated buildings: A review [J].
Barbosa, Sabrina ;
Ip, Kenneth .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 40 :1019-1029
[5]   2D whole-building hygrothermal simulation analysis based on a PGD reduced order model [J].
Berger, Julien ;
Mazuroski, Walter ;
Mendes, Nathan ;
Guernouti, Sihem ;
Woloszyn, Monika .
ENERGY AND BUILDINGS, 2016, 112 :49-61
[6]  
Brooks A., 1983, CORBUSIER ARMEE SALU
[7]  
Bryan H., 1991, P 9 INT PLEA C SEV 2
[8]   Energy performance assessment of double-skin facade with thermal mass [J].
Fallahi, Ali ;
Haghighat, Fariborz ;
Elsadi, Hafia .
ENERGY AND BUILDINGS, 2010, 42 (09) :1499-1509
[9]   Double skin glazed facades in sunny Mediterranean climates [J].
Flores Larsen, Silvana ;
Rengifo, Luis ;
Filippin, Celina .
ENERGY AND BUILDINGS, 2015, 102 :18-31
[10]   Experimental and numerical analysis of heat transfer and airflow on an interactive building facade [J].
Fuliotto, Roberto ;
Cambuli, Francesco ;
Mandas, Natalino ;
Bacchin, Nicoletta ;
Manara, Giampiero ;
Chen, Qingyan .
ENERGY AND BUILDINGS, 2010, 42 (01) :23-28