Transcranial color-coded duplex sonography in unilateral flow-restrictive extracranial carotid artery disease

被引:0
|
作者
Baumgartner, RW
Baumgartner, I
Mattle, HP
Schroth, G
机构
[1] UNIV BERN, INSELSPITAL, DEPT ANGIOL, CH-3020 BERN, SWITZERLAND
[2] UNIV BERN, INSELSPITAL, DEPT NEURORADIOL, CH-3020 BERN, SWITZERLAND
关键词
arteries; stenosis and occlusion; ultrasound; doppler;
D O I
暂无
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
PURPOSE: To provide transcranial color-coded duplex flow-velocity data for the basal cerebral arteries in patients with unilateral flow-restrictive extracranial carotid artery disease, and to compare these data with the flow velocities obtained in healthy control subjects. METHODS: Transcranial color-coded duplex sonography was performed in 78 patients with different patterns of cross flow through the anterior and posterior communicating arteries associated with unilateral obstruction (70% to 100%; 46 stenoses and 32 occlusions) of the internal carotid arteries. Peak systolic, mean, and end diastolic velocities were measured in the anterior, middle, and precommunicating and postcommunicating posterior cerebral arteries. These measurements were compared with the values obtained in 125 age- and sex-matched healthy control subjects. RESULTS: Patients with anterior communicating artery cross flow to the middle cerebral artery (63%) had increased peak velocity in the anterior cerebral artery and decreased peak velocity in the middle cerebral artery on the obstructed (ipsilateral) side, and increased peak velocity in the anterior cerebral artery on the unobstructed (contralateral) side. Patients with anterior communicating artery cross flow to the pericallosal artery (19%) had increased contralateral peak systolic velocity and mean anterior cerebral artery velocities. Patients without anterior communicating artery cross flow (18%) had normal peak velocities in the anterior and middle cerebral arteries. Patients with posterior communicating artery cross flow (42%) had ipsilaterally decreased peak systolic and mean middle cerebral artery velocities and increased peak velocities in the precommunicating posterior cerebral artery. Patients without posterior communicating artery cross flow (58%) had ipsilaterally decreased peak systolic and mean middle cerebral artery velocities. CONCLUSION: Our findings suggest that typical abnormalities of basal cerebral artery flow velocities occur in patients with unilateral 70% to 100% obstruction of the internal carotid arteries resulting in different patterns of cross flow through the circle of Willis.
引用
收藏
页码:777 / 783
页数:7
相关论文
共 50 条
  • [1] Transcranial color-coded duplex sonography
    Ralf W. Baumgartner
    Journal of Neurology, 1999, 246 : 637 - 647
  • [2] Competence for transcranial color-coded Duplex sonography is rapidly acquired
    Klinzing, S.
    Steiger, P.
    Schuepbach, R. A.
    Bechir, M.
    Brandi, G.
    MINERVA ANESTESIOLOGICA, 2015, 81 (03) : 298 - 304
  • [3] Evaluation of Transcranial Color-Coded Duplex Sonography for Cerebral Artery Stenosis or Occlusion
    Hou, Wei Hua
    Liu, Xi
    Duan, Yun You
    Wang, Jia
    Sun, Si Guo
    Deng, Jian Ping
    Qin, Huai Zhou
    Cao, Tie Sheng
    CEREBROVASCULAR DISEASES, 2009, 27 (05) : 479 - 484
  • [4] Transcranial color-coded duplex sonography in the evaluation of collateral flow through the circle of Willis
    Baumgartner, RW
    Baumgartner, I
    Mattle, HP
    Schroth, G
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1997, 18 (01) : 127 - 133
  • [5] Carotid and transcranial color-coded duplex sonography in different types of carotid-cavernous fistula
    Chen, YW
    Jeng, JS
    Liu, HM
    Hwang, BS
    Lin, WH
    Yip, PK
    STROKE, 2000, 31 (03) : 701 - 706
  • [6] Intimal carotid artery fibromuscular dysplasia displayed by color-coded duplex sonography
    Winter, R
    Ringleb, P
    Hacke, W
    NERVENARZT, 1998, 69 (10): : 905 - 908
  • [7] Diagnosis of middle cerebral artery occlusion with transcranial color-coded real-time sonography
    Kimura, K
    Hashimoto, Y
    Hirano, T
    Uchino, M
    Ando, M
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1996, 17 (05) : 895 - 899
  • [8] Assessment of dural arteriovenous fistulae by transcranial color-coded duplex sonography
    Harrer, JU
    Popescu, O
    Henkes, HH
    Klötzsch, C
    STROKE, 2005, 36 (05) : 976 - 979
  • [9] In reply to "Bias in the interpretation of the transcranial color-coded duplex sonography register"
    Arroyo Diez, M.
    Zabalegui Perez, A.
    Kaminsky, G.
    Perez Cabo, E. M.
    MEDICINA INTENSIVA, 2019, 43 (04) : 256 - 256
  • [10] ASSESSING CIRCLE OF WILLIS BLOOD CIRCULATION IN DOGS WITH TRANSCRANIAL COLOR-CODED DUPLEX SONOGRAPHY
    Duque, Francisco J.
    Dominguez-Roldan, Jose M.
    Ruiz, Patricia
    Zaragoza, Concepcion
    Barrera-Chacon, Rafael
    VETERINARY RADIOLOGY & ULTRASOUND, 2009, 50 (05) : 530 - 535