Advances in data center thermal management

被引:97
作者
Fulpagare, Yogesh [1 ]
Bhargav, Atul [1 ]
机构
[1] Indian Inst Technol Gandhinagar, Energy Syst Lab, Ahmadabad 382424, Gujarat, India
关键词
Data center; Thermal management; Heat dissipation; Performance metrics; DATA CENTER TEMPERATURE; AIR-FLOW DISTRIBUTION; OF-THE-ART; ENERGY EFFICIENCY; PERFORATED TILES; HEAT-TRANSFER; OPTIMIZATION; PERFORMANCE; SYSTEMS; CLUSTER;
D O I
10.1016/j.rser.2014.11.056
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
With the increase in electronic traffic, heat generated by electronic equipment, and the concomitant costs of powering cooling systems in electronic data centers are increasing continually. Various research groups working in academic institutions, research laboratories and industries have been applying a variety of tools to study and improve performance of data centers. This paper reviews recent contributions to the state of knowledge in data center thermal management. First, we review numerical and experimental studies on the most common air-cooled raised floor plenum type data centers. We then summarize published research on rack layout, efficiency and performance metrics for data centers, dynamic control and life cycle analyses, and validation of numerical models. Finally, we review some recently proposed cooling strategies and numerical optimization efforts. We find that the research carried out on thermal management of data centers has helped improve performance in many instances (such as rear door water cooled heat exchanger type rack), and has helped establish some physics-based criteria for data center designers. Based on the trends observed in this review, we expect further improvements to all aspects of data center design and operation in the near future, with a focus on real-time measurement & control, model validation and heuristics based optimization. In addition, some significant changes such as thermal energy storage and smart-grid capabilities are also expected to be incorporated into data center control strategies. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:981 / 996
页数:16
相关论文
共 116 条
[51]   HOT WATER COOLED HEAT SINKS FOR EFFICIENT DATA CENTER COOLING: TOWARDS ELECTRONIC COOLING WITH HIGH EXERGETIC UTILITY [J].
Kasten, Peter ;
Zimmermann, Severin ;
Tiwari, Manish K. ;
Michel, Bruno ;
Poulikakos, Dimos .
FRONTIERS IN HEAT AND MASS TRANSFER, 2010, 1 (02)
[52]  
Kelkar K., 2010, 12th IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems, P1, DOI DOI 10.1109/ITHERM.2010.5501416
[53]  
Kien MM, 2009, COST ENERGY AWARE LO
[54]  
KIFF P, 1995, FRESH APPROACH COOLI
[55]  
Kumar P, 2010, P 12 INT C THERM THE
[56]  
Kumar P, 2011, P IEEE SEMICOND THER, P90, DOI 10.1109/STHERM.2011.5767184
[57]  
Li L., 2011, Proceedings of the 17th ACM SIGKDD Conference on Knowledge Discovery and Data Mining (KDD), P1370
[58]   Strategies for data center temperature control during a cooling system outage [J].
Lin, Mi ;
Shao, Shuangquan ;
Zhang, Xuanhang ;
VanGilder, James W. ;
Avelar, Victor ;
Hu, Xiaopeng .
ENERGY AND BUILDINGS, 2014, 73 :146-152
[59]   Heat transfer modeling in data centers [J].
Lopez, Vanessa ;
Hamann, Hendrik F. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2011, 54 (25-26) :5306-5318
[60]   Investigation of air management and energy performance in a data center in Finland: Case study [J].
Lu, Tao ;
Lu, Xiaoshu ;
Remes, Matias ;
Viljanen, Martti .
ENERGY AND BUILDINGS, 2011, 43 (12) :3360-3372