The maximum ceiling gas temperature in a large tunnel fire

被引:184
|
作者
Li, Ying Zhen [1 ]
Ingason, Haukur [1 ]
机构
[1] SP Tech Res Inst Sweden, SE-50115 Boras, Sweden
关键词
Maximum temperature; Heat release rate; Ventilation velocity; Effective tunnel height; VENTILATION; TESTS;
D O I
10.1016/j.firesaf.2011.12.011
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Effects of different ventilation systems, ventilation velocities, heat release rates, tunnel geometries and fire sources on the maximum excess gas temperature beneath the ceiling in large tunnel fires are analyzed. Data from numerous model scale tests and most of the large scale tunnel fire tests that have been performed worldwide are used and analyzed. Correlations for the maximum ceiling excess gas temperature in the vicinity of the fire source are proposed for low and high ventilation flows. The temperature data indicate two regions, depending on the dimensionless ventilation velocity. Each can be divided into two sub-regions. The first sub-region exhibits linear increase which transits into a constant period, depending on the fire size, ventilation and the effective tunnel height. The maximum excess gas temperature is found to be 1350 degrees C. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:38 / 48
页数:11
相关论文
共 50 条
  • [1] The maximum ceiling gas temperature in a large tunnel fire (vol 48, pg 38, 2012)
    Li, Ying Zhen
    Ingason, Haukur
    FIRE SAFETY JOURNAL, 2012, 50 : 63 - 63
  • [2] Position of Maximum Ceiling Temperature in a Tunnel Fire
    Ying Zhen Li
    Haukur Ingason
    Fire Technology, 2014, 50 : 889 - 905
  • [3] Position of Maximum Ceiling Temperature in a Tunnel Fire
    Li, Ying Zhen
    Ingason, Haukur
    FIRE TECHNOLOGY, 2014, 50 (04) : 889 - 905
  • [4] The maximum gas temperature rises beneath the ceiling in a longitudinal ventilated tunnel fire
    Yao, Yongzheng
    He, Kun
    Peng, Min
    Shi, Long
    Cheng, Xudong
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2021, 108
  • [5] Experimental investigation on maximum gas temperature beneath the ceiling in a branched tunnel fire
    Huang, Youbo
    Li, Yanfeng
    Li, Junmei
    Li, Jiaxin
    Wu, Ke
    Zhu, Kai
    Li, Haihang
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2019, 145
  • [6] Maximum gas temperature rise beneath the ceiling in a portals-sealed tunnel fire
    Yao, Yongzheng
    He, Kun
    Peng, Min
    Shi, Long
    Cheng, Xudong
    Zhang, Heping
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2018, 80 : 10 - 15
  • [7] Study on the influence of the longitudinal position of fire source and tunnel width on the maximum ceiling gas temperature
    He, Lu
    Liao, Ke
    Zhu, Guoqing
    CASE STUDIES IN THERMAL ENGINEERING, 2023, 52
  • [8] A study for predicting the maximum gas temperature beneath ceiling in sealing tactics against tunnel fire
    Chen, Changkun
    Zhang, Yulun
    Lei, Peng
    Jiao, Weibing
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2020, 98 (98)
  • [9] Study on the maximum ceiling temperature and downstream temperature distribution in inclined tunnel fire
    Sun, Chaopeng
    Weng, Miaocheng
    Liu, Fang
    Yang, Haoran
    Zhu, Xinyi
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2024, 153
  • [10] Maximum temperature of smoke beneath ceiling in tunnel fire with vertical shafts
    Wang, Yan Fu
    Li, Yu Lian
    Yan, Pei Na
    Zhang, Biao
    Jiang, Jun Cheng
    Zhang, Li
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2015, 50 : 189 - 198